My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1630 RUCKER AVE 2023-05-23
>
Address Records
>
RUCKER AVE
>
1630
>
1630 RUCKER AVE 2023-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2023 9:17:26 AM
Creation date
5/19/2023 3:32:49 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
1630
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2018 Washington State Energy Code—Residential <br /> Prescriptive Energy Code Compliance for All Climate Zones in Washingto ea <br /> Single Family—New&Additions(effective February 1,2021) Version 1. e <br /> SEp <br /> These requirements apply to all IRC building types, including detached one- two-family 1 y <br /> dwellings and multiple single-family dwellings(townhouses). 7' ' ?�?� <br /> Project Information Contact Information ' 't e V , �i <br /> ADDITION • (KEN&SUSAN RIKER `Sc�Vj� S 71' <br /> 1630 RUCKER AVE., EVERETT,WA 98201 1425-303-8016 <br /> Instructions:This single-family project will use the requirements of the Prescriptive Path below and <br /> incorporate the minimum values listed. Based on the size of the structure,the appropriate number of <br /> additional credits are checked as chosen by the permit applicant. <br /> Provide all information from the following tables as building permit drawings:Table R402.1-Insulation and <br /> Fenestration Requirements by Component,Table R406.2-Fuel Normalization Credits and 406.3-Energy Credits. <br /> Authorized Representative Date <br /> All Climate Zones(Table R402.1.1) <br /> R Value a 1 U-Factor <br /> Fenestration U-Factor b n/a 0.30 <br /> Skylight U-Factor b n/a 0.50 <br /> Glazed Fenestration SHGC b'e n/a n/a <br /> Ceiling e 49 0.026 <br /> Wood Frame Wall g,h 21 int 0.056 <br /> Floor 30.... _._.....-_.._.-.............. 0.029......................................................_................. <br /> • <br /> Below Grade Wall`,h 10/15/21 int+TB 0.042 , <br /> Slab di R-Value&Depth 10,2 ft I n/a <br /> R-values are minimums.U-factors and SHGC are maximums.When insulation is installed in a cavity that is less <br /> a !than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix <br /> (Table A101.4 shall not be less than the R-value specified in the table. <br /> b The fenestration U-factor column excludes skylights. <br /> "10/15/21+5TB"means R-10 continuous insulation on the exterior of the wall,or R-15 continuous insulation on <br /> the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the basement wall at <br /> c (the interior of the basement wall."10/15/21+5TB"shall be permitted to be met with R-13 cavity insulation on <br /> (the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall."5TB" <br /> means R-5 thermal break between floor slab and basement wall. <br /> d ,R 10 continuous insulation is required under heated slab on grade floors.See Section R402.2.9.1. <br /> For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38 if the full insulation depth <br /> e extends over the top late of the exterior wall. <br /> R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter <br /> f slab insulation when applied to existing slabs complying with Section R503.1.1.If foam plastic is used,it shall <br /> meet the requirements for thermal barriers protecting foam plastics. <br /> For log structures developed in compliance with Standard ICC 400,log walls shall meet the requirements for <br /> g climate zone 5 of ICC 400. <br /> Int.(intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard <br /> h `:framing 16 inches on center, 78%of the wall cavity insulated and headers insulated with a minimum of R-10 <br /> l insulation. <br /> Prescriptive Path—Single Family 2018 Washington State Energy Code-R 1 b <br />
The URL can be used to link to this page
Your browser does not support the video tag.