Laserfiche WebLink
1 5 • <br /> DISCONNECTTILITY LUM10 <br /> SMARTTO <br /> ENERGY TODAY <br /> ELECTRIC SHOCK HAZARD LABEL LOCATION: (SET) <br /> AC DISCONNECT 1550 DIGITAL DR,LEHI,UT <br /> TERMINALS ON BOTH LINE AND LOAD SIDES MAY PER CODE: NEC 690.56(C)(2) 84043,USA <br /> BE ENERGIZED IN THE OPEN POSITION <br /> LABEL LOCATION: <br /> POINT OF INTERCONNECTION,MAIN SERVICE flPHOTOVOLTAIC AC DISCONNECT <br /> DISCONNECT,AC DISCONNECT,AC COMBINER, <br /> INVERTER IRATED AC OUTPUT CURRENT • • <br /> PER CODE:NEC 690.13(B) NOMINAL OPERATING , VOLTS <br /> SYSTEM INFO <br /> LABEL LOCATION: (22)Q CELLS <br /> ACAUTION INTERACTIVE SYSTEM POINT OF INTERCONNECTION Q PEAK DUO BILK ML-G10+ <br /> (400W) <br /> PER CODE:NFPA 70,NEC 690.54 <br /> (22)ENPHASE <br /> IQ8PLUS-72-2-US(240V) <br /> POWERDUAL SOURCE DC SYSTEM SIZE:8.800 kWDC <br /> SECOND <br /> , SOURCE 7 AC SYSTEM SIZE:6.600 kWAC <br /> PHOTOVOLTAIC PHOTOVOLTAIC POWER SOURCE <br /> LABEL LOCATION: <br /> F <br /> CONDUIT REVISIONS <br /> LABEL LOCATION: PER CODE:NEC 690.31(D)(2) DESCRIPTION DATE REV <br /> MAIN SERVICE DISCONNECT/AC DISCONNECT/ <br /> MAIN SERV CE PANEL/ REVENUE METER/AC <br /> COMBINER <br /> PER CODE:NEC 705.12(C) 8 CAUTION : SOLAR CIRCUIT <br /> 3 <br /> CAUTION : SOLAR ELECTRIC LABEL LOCATION: PROJECT NAME&ADDRESS <br /> SYSTEM CONNECTED MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR CONDUIT,RACEWAYS, <br /> ENCLOSURES,AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT,AT TURNS AND <br /> LABEL LOCATION: ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES U) <br /> PER CODE:IFC 606.11.1.4 <br /> POINT OF INTERCONNECTION&INVERTER M <br /> PER CODE:NEC 690.15&690.13(B) O <br /> N <br /> 00gWARNING - Electric Shock Hazard <br /> SOLAR PV SYSTEM EQUIPPED parts Q o <br /> 4 WITH RAPID SHUTDOWN JK Contactprovider for assistance o <br /> O o <br /> LABEL LOCATION: W W O <br /> TURN RAPID INVERTER&JUNCTION BOXES(ROOF) U) U ()� O <br /> SHUTDOWN SWITCH PER CODE:NEC 690.13(G)(3)&690.13(G)(4) O Z W o <br /> TO THE, <br /> Z W > LO <br /> POSITION TO SHUT SOLAR ELECTRic J � W � <br /> DOWN PV SYSTEM vv PANELS W <br /> L <br /> AND REDUCE 2 LL.I W O <br /> SHOCK HAZARD IN I- ()f > <br /> THE ARRAY Q Q <br /> O Q <br /> LABEL LOCATION: <br /> MAIN SERVICE DISCONNECT IF MSDIS OUTSIDE H <br /> PLACE IT THERE/IF MSD IS INSIDE PLACE ON THE W> <br /> AC DISCONNECT <br /> PER CODE:2020 NEC 690.56(C) LO <br /> O <br /> ti <br /> LID <br /> DATE: 11/3/2022 <br /> SHEET NAME <br /> SIGNAGE <br /> ADHESIVE FASTENED SIGNS SHEET SIZE <br /> • THE LABEL SHALL BE SUITABLE FOR THE <br /> ENVIRONMENT WHERE IT IS INSTALLED. ANSI B <br /> • WHERE REQUIRED ELSEWHERE IN THIS CODE,ALL 11" X 17" <br /> FIELD APPLIED LABELS,WARNING AND MARKINGS <br /> SHOULD COMPLY WITH ANSI 2535.4 [NEC 110.21(B) <br /> FIELD MARKING]. SHEET NUMBER <br /> • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PV-9 <br /> PROPERLY ADHERED.VINYL SIGNS SHALL BE WEATHER <br /> RESISTANT[IFC 605.11.1.31 <br />