• • <br /> Drew Martin <br /> From: Drew Martin <br /> Sent: Wednesday, March 8, 2023 9:26 AM <br /> To: Colie Wilson <br /> Subject: RE: City of Everett Permit Services: 5901 23rd Drive W, Suite 100 (M2303-002) - First <br /> Building Review <br /> Hello, Colie. <br /> Your application has been received and a permit set up. However,the submitted documents are not <br /> sufficiently developed for us to perform a comprehensive review at this time. <br /> Construction-level documents should be submitted for review. Two complete sets of the revised drawings <br /> should be submitted to replace the previously submitted drawing sets. Preliminary comments are provided <br /> below to assist in preparing the drawings, but these are not intended to provide a comprehensive review. The <br /> resubmittal documents should include an itemized response letter clarifying how the review comments below <br /> have been addressed. <br /> Review Comments: <br /> 1. Aerial images of the building have been provided showing the approximately plan locations of new <br /> units. Floor plans should be provided showing the location, including the story, of each unit. <br /> 2. The drawings should include a schedule of all equipment proposed in the project. Weights for each <br /> unit should be specified. Where new units are replacing old units,the weights of both the old and new <br /> units should be specified. <br /> 3. If installation of new units requires substantial structural modifications to the supporting framing, a <br /> building permit will be required. The application should include drawings and calculations for the <br /> proposed modifications. Minor modifications (e.g., blocking between existing framing, curbs, <br /> sheathing penetrations that do not cut framing members) may be performed within the scope of the <br /> mechanical permit application. <br /> 4. lithe new units are suspended, details and calculations for the gravity supports and lateral bracing of <br /> the unit is required if it exceeds 20 lbs. See IBC Section 1613.1 and ASCE 7-16 Chapter 13. <br /> 5. Details will be required when penetrating fire-rated assemblies;the applicant is responsible to <br /> evaluate the building and determine the Construction Type of the building per IBC Section 601, and the <br /> locations and ratings of assemblies. Penetration details should be provided for the rated assemblies <br /> per IBC Chapter 7. <br /> Review of your project will be performed in the order received once the required documentation has been <br /> submitted. Please let me know if you have questions. <br /> Drew Martin, P.E.,S.E. <br /> L. <br /> Associate Engineer—Commercial Plans Examiner I Permit Services <br /> 425.257.8810 13200 Cedar Street, 2"d Floor, Everett,WA 98201 <br /> EVERETT Phone Hours: M/W/T:8 am - 12 pm & 1 pm—3 pm;Tu: 1:00pm-3:00pm <br /> everettwa.gov/permits I Facebook I Twitter <br /> 1 <br />