|
Air Conditioning
<br /> Heating
<br /> Controls
<br /> Sales
<br /> Service
<br /> HVAC GENERAL NOTES DUCT NOTES LEGAL DESCRIPTION: LEGEND & ABBREVIATIONS C Installation
<br /> 1. VERIFY SITE CONDITIONS. 1. DUCT CONSTRUCTION AND INSTALLATION PER LATEST SMACNA STANDARDS AND THE SYMBOL ABBREV. DESCRIPTION SYMBOL ABBREV. DESCRIPTION '•QUALITYASSURED-
<br /> 2018 SMC AS REQUIRED BY THE LOCAL CODE. PROVIDE METAL DUCT, EXCEPT AS Section 18 Township 29 Range 05 Quarter SE LOT A14 OF BSP
<br /> 2. THERMOSTAT LOCATIONS: VERIFY ALL WALL MOUNTED CONTROL LOCATIONS WITH ARCHITECT/GC. NOTED. FOR DIV 3 OF PORT OF EV N MARINA BSP16-004 RLC UND AFN 0 ® SUPPLY DUCT ♦ FIRE DAMPERED DUCT pacific air control, inc.
<br /> 3. CODES: COMPLY WITH ALL LOCAL & STATE GOVERNING CODES. PENETRATION OF A
<br /> 2. BALANCING DAMPERS: PROVIDE ON ALL SUPPLY RUN OUT DUCTS UP STREAM OF 201708075002&AS CORR BY AFN 201812265002 BEING A PTN OF RETURN/EXHAUST DUCT 1916220th Street SE Suite M101
<br /> 4. COORDINATE DUCTWORK AND GRILLE LOCATIONS WITH LIGHTING AND OTHER RELATED TRADES WITH HORIZONTAL SEPARATION
<br /> DIFFUSERS. SEA/4 SD SEC EX BLDG (HOTELINDIGO) ON 29051800402401 Bothell,WA 98011
<br /> ARCHITECT APPROVAL. VERIFY CLEARANCES & CEILING ELEVATIONS BEFORE INSTALLATION. SL SOUNDLINED DUCT FIRE DAMPERED DUCT ph:(206)682-6393 fax:(206)340-2270
<br /> 5. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW EXACT ROUTING OR EVERY 3. DUCT INSULATION: DUCTS, SHAFTS AND PLENUMS SHALL BE INSULATED TO MINIMUM r Contractor's License No.:PACIFAC23OP8
<br /> OFFSET WHICH MAY BE REQUIRED. OF R-8 AND IN ACCORDANCE WITH THE SECTION C403.2.8 OF 2018 SEC. MANUAL VOLUME DAMPER PENETRATION OF A
<br /> 6. SEISMIC BRACING: PROVIDE TO MEET LOCAL CODE REQUIREMENTS. REFER TO THE ASHRAE 4. DUCT SEALING—GENERAL: 0 TO 2" STATIC PRESSURE — SEAL ALL TRANSVERSE FC FLEX CONNECTOR VERTICAL SEPARATION www.pacificaircontrol.com
<br /> STANDARDS "PRACTICAL GUIDE TO SEISMIC RESTRAINT". JOINTS AND LONGITUDINAL SEAMS ON ALL DUCTS. ABOVE 2"-SEAL SEAMS, JOINTS TV TURNING VANES 01 TIMER 0-4 HR ADJUSTABLE
<br /> 7. EXHAUST FAN TERMINATION: SHALL NOT BE LESS THAN 3 FEET FROM A PROPERTY LINE OR AND WALL PENETRATIONS. INSIDE BUILD: DURODYNE "DDS-181" GRAY OR TAX PARCEL N O B E R: 29051800402400
<br /> OPENINGS INTO A BUILDING, E.G., OPERABLE WINDOWS AND DOORS, OR DISTANCE AS REQUIRED APPROVED EQUAL PER UL 181 A-M, 1818-M LISTED. OUTSIDE: POLYURETHANE, EC END CAP (D THERMOSTAT/HVAC UNIT #
<br /> PER LOCAL CODE. MAMECO VULKEM 116. OR APPROVED EQUAL. ® SD SUPPLY DIFFUSER, CEILING O SENSOR/HVAC UNIT #
<br /> 8. TEST, ADJUST, & BALANCE: PROVIDE PROPER SYSTEM TESTING, ADJUSTING, AND BALANCING, 5. TURN VANES: PROVIDE SINGLE THICKNESS TURN VANES (SEE DETAIL) IN ALL MAJOR
<br /> INCLUDING WRITTEN REPORTS TO BE PROVIDED TO OWNER. BALANCE TO WITHIN 10% OF DESIGN. SQUARE DUCT ELBOWS, TEES, OR TURNS WITH INSIDE RADIUS LESS THAN 3/4 ® MG MAKEUP GRILLE O SENSOR (CEILING MOUNT)
<br /> 9. OPERATION & MAINTENANCE BOOKLET: PROVIDE 0 & M MANUAL TO OWNER. INCLUDE CUT SHEETS DUCT WIDTH. SQUARE BRANCH DUCT TAPS SHALL BE 45 DEGREE TYPE PER RG RETURN GRILLE, CEILING EXHAUST FAN PIPE/DUCT UP
<br /> ON MAIN EQUIPMENT AND CONTROLS, MAINTENANCE INSTRUCTIONS, AND MARKED UP AS-BUILT SMACNA STANDARD. ` ="°
<br /> DRAWING. 6. FLEX DUCT (INSULATED): FOR GRILLE RUN OUTS UP TO 6 FT. LONG, EXCEPT AS +� 0 EG EXHAUST GRILLE, CEILING /
<br /> 10. COMMISSIONING: PRIOR TO PASSING THE FINAL INSPECTION OR OBTAINING A CERTIFICATE OFNOTED. PROVIDE ADJUSTABLE METAL ELBOWS ON ALL TURNS, UNLESS A SMOOTH 0 PIPE/DUCT DOWN
<br /> OCCUPANCY, PROVIDE THE EVIDENCE OF SYSTEM COMMISSIONING AND COMPLETION IN ACCORDANCE FULL RADIUS TURN IS MADE. SECURE CORE WITH APPROVED NYLON OR METAL A TO TRANSFER GRILLE, CEILING
<br /> WITH THE PROVISIONS OF SECTION C408 OF THE 2018 SEC WORM DRIVE CLAMPS. NO DUCT TAPE JOINTS & SCREWS ALLOWED. '^/ —1 SIDEWALL SUPPLY/MAKEUP PIPE TEE DOWN
<br /> 11. WALK—THRU INSTRUCTION: PROVIDE ON SITE WALK—THRU FOR CUSTOMER TO DEMONSTRATE 7• SOUND LINER: PROVIDE SOUND LINED METAL SUPPLY & RETURN DUCTS AS SHOWN AREA OF SIDFWALL RETURN/EXHAUST PIPE TEE UP
<br /> OPERATION OF SYSTEM AND ANSWER QUESTIONS. ON PLANS. MANVILLE PERMACOTE LINACOUSTIC FLEXIBLE FIBERGLASS LINER, WITH
<br /> 12, ROOF TOP UNITS ON CURB: SEAL HOLES AND CRACKS BETWEEN DUCT AND ROOF DECK INSIDE ACRYLIC SURFACE TREATMENT OR EQUAL. FABRICATE AND INSTALL PER DUCT LINER WORK IT—v EQUIPMENT TAG EXIST DUCTWORK, EQUIP
<br /> FACTORY ROOF CURB FOR NOISE CONTROL. STANDARD OF NORTH AMERICAN INSULATION MANUFACTURER'S ASSOC. } AFF ABOVE FINISHED FLOOR NEW DUCTWORK, EQUIP
<br /> 13. GAS PIPE: SCHEDULE 40, BLACK STEEL. PAINT PIPE EXPOSED TO WEATHER. I
<br /> OUTSIDE AIR DUCT IS NOT INSULATED THROUGH UNCONDITIONED AREA. m � CEILING RADIATION DAMPER �
<br /> 14. SIZES: ALL PIPE SIZES SHOWN ARE MINIMUM. 8. FLEX CONNECTORS: PROVIDE ON ALL DUCT HOOK—UPS TO ISOLATE AIR HANDLING BD, BDD BACKDRAFT DAMPER
<br /> 15, PIPE HANGERS: SWIVEL LOOP STYLE, MICHIGAN NO.100 OR CLEVIS STYLE, NO.400 OR EQUAL EQUIPMENT. (NEOPRENE COATED FIBERGLASS FABRIC TYPE) .m r BS BIRDSCREEN VALVE J
<br /> BRAND, WITH ALTHERED STEEL ROD SIZED PER INDUSTRY STANDARDS. 9. DUCT SIZE CHANGES: ROUND GALVANIZED DUCTS MAY BE SUBSTITUTED FOR BALANCING VALVE V LU N
<br /> 16. ELECTRICAL: ALL EQUIPMENT TO HAVE A POSITIVE MEANS OF DISCONNECT ADJACENT TO AND IN DN DOWN Uj 00
<br /> PROVIDE CIRCULAR EQUIVALENT OF
<br /> SIGHT FROM EQUIPMENT SERVED. PROVIDE A 120 VOLT RECEPTACLE LOCATED WITHIN 25 FEET OF RECTANGULAR DUCTS THAT ARE NOT LINED. � W 0)EQUIPMENT FOR SERVICE & MAINTENANCE PURPOSES 2018 SMC SECTION 301.10). LINE VOLTAGE RECTANGULAR DUCT. OTHER EQUIVALENT RECTANGULAR DUCT SIZES MAY BE EA EXHAUST AIR ADC ADJACENT
<br /> WORK BY OTHERS. ( SUBSTITUTED TO BETTER FIT SPACE. OA, OSA OUTSIDE AIR BSC BIOLOGICAL SAFETY CABINET Q
<br /> 17. SUSPENDED MECHANICAL EQUIPMENT AND APPLIANCES SHALL HAVE RIGID VERTICAL HANGERS AND 10. TEMPORARY DUCT CLOSURE: SEAL OFF DUCTWORK DURING CONSTRUCTION TO C
<br /> KEEP OUT CONSTRUCTION DUST, ESPECIALLY FLOOR BOOTS AND LOW WALL RA RETURN AIR CFH CHEMICAL FUME HOOD O
<br /> BE BRACED IN BOTH HORIZONTAL DIRECTIONS. OPENINGS. SA SUPPLY AIR CFM CUBIC FEET PER MINUTE M
<br /> (N) NEW DB DUCT BOARD r IJJ
<br /> (E)/EXIST EXISTING L,S LIQUID, SUCTION 00
<br /> Cq VICINITY MAP (R) RELOCATED N NECK O O ;
<br /> NTs BWG BOTTOM WALL GRILLE NIC NOT IN CONTRACT Q r LU
<br /> TWG TOP WALL GRILLE ON OUTSIDE AIR INTAKE
<br /> TYR TYPICAL RD ROUND DIFFUSER UjW
<br /> VD VOLUME DAMPER SHC SENSIBLE HEATING CAPACITY
<br /> P% DEMO SR SUPPLY REGISTER
<br /> .j �' �� ✓�
<br /> TO TOTAL COOLING U.
<br /> 0
<br /> REVISIONS VEL VELOCITY o
<br /> WH WATER HEATER
<br /> DIFFUSERS/GLILLS SCHEDULE ! SC SOUND CAN w
<br /> AIR TERMINAL LEGEND 0
<br /> TAG NUMBER MAKE MODEL NOTE NECK SIZE (INCHES)
<br /> ♦�- GRILLE, REGISTER, XX 8x8 o
<br /> SD-1 1 SHOEMAKER MAO SERIES 8X8
<br /> �L DIFFUSER IN LEGEND 140 SQUARE OR RECTANGULAR �
<br /> SD-2 2 SHOEMAKER SD340 14X6
<br /> RG-1 1 SHOEMAKER 1050 SERIES 8X8 Allow AIR QUANTITY (CFM) O
<br /> - M \` d
<br /> O
<br /> -/ 5F XX 8"0 NECK SIZE (INCHES)
<br /> 140 ROUND
<br /> Air Quantity (CFM) NO DATE DEscmPnoN
<br /> ARROWS INDICATE AIR PATTERN FOR CEILING DIFFUSERS 02/21/23 CONSTRUCTION ISSUE
<br /> NO ARROWS INDICATE FOUR WAY PATTERN
<br /> FIRE SPRINKLER HEADS TO BE FAST REACTION TYPE BY OTHERS. Q
<br /> }
<br /> 'i
<br /> DESCRIPTION OF WORK: THIS DRAWING IS THE SOLE PROPERTY P PACIFIC AIR
<br /> r� r�r\ CONTROL,INC. ANY REPRODUCTION,DUPLICATION,
<br /> FREEDOM BOAT CLUB AREA OF WORK ADDDI°Ns ND OF PACIFIC REQUIRE THE
<br /> WRITTEN APPRWAR OF PACIFIC AIR CONTROL,INC.
<br /> NTS PFpJECT NANAGEF DESIGNED BY
<br /> 1. FURNISH AND INSTALL MAIN TRUNK LINE WITH TWO (2) TAKEOFFS DD DD/BO
<br /> DRAWN BY BY
<br /> 2. FURNISH AND INSTALL TWO (3) DIFFUSERS BG DDNED
<br /> SCALE 11-111
<br /> 3. AIR BALANCE AS NOTED T230104
<br /> DRAxrNc nnrs
<br /> LEGEND &ABBREVIATIONS
<br /> DRAWING INDEX
<br /> VICINITY MAP, NOTES,
<br /> M-1 LEGEND & ABBREVIATIONS, VICINITY MAP, NOTES, EQUIPMENT SCHEDULE EQUIPMENT SCHEDULE
<br /> DETAILS
<br /> M-2 EXISTING/NEW HVAC PLAN
<br /> N�Ne�r
<br /> M- 1
<br /> of 2
<br /> Construction Dodd- -SOLD 2023 SOLD 230104 Freedom Boot Club En ineerin Freedom Boot Club. cDPralcxT®swl a
<br />
|