ID TYPICAL INITIAL CONDUCTOR FINAL CONDUCTOR CONDUCTOR CONDUIT #OF CURRENT-CARRYING CONDUIT OCPD EGC TEMP.CORR. CONDUIT CONT. MAX. BASE DERATED TERM. LENGTH VOTAGE <br /> LOCATION LOCATION PARALLEL CONDUCTORS IN FILL FACTOR FILL CURRENT CURRENT AMP. AMP. TEMP. DROP <br /> CIRCUITS CIRCUIT PERCENT FACTOR RATING Lumio <br /> 1 1 ARRAY JUNCTION BOX 12 AWG Q CABLE COPPER - 1 2 N/A N/A 6 AWG BARE 0.82 (48°C) N/A 15.73A 19.66A N/A N/A 75°C 52FT -7-76-- <br /> COPPER <br /> SMART ENERGY TODAY <br /> 2 1 JUNCTION BOX IQ COMBINER BOX 10 AWG THWN 2 COPPER MIN 0.75"DIA 1 2 16.70% 20A 6 AWG THWN-2 1 (26°C) 1 15.73A 19.66A 40A 40.00A 75°C 12FT 0.20% (SET) <br /> EMT COPPER 1550 DIGITAL DR,LEHI,UT <br /> 3 1 IQ COMBINER BOX NON FUSED AC 6 AWG THWN 2 COPPER MIN 0.75"DIA 1 3 36.77% N/A 6 AWG THWN-2 1 (26°C) 1 15.73A 19.66A 75A 75.00A 75°C 5FT 0.03% 84043,USA <br /> DISCONNECT EMT COPPER <br /> 4 1 NON FUSED AC MSP 6 AWG THWN 2 COPPER MIN 0.75"DIA 1 3 36.77% 20A 6 AWG THWN-2 1 (26°C) 1 15.73A 19.66A 75A 75.00A 75°C 5FT 0.03% <br /> DISCONNECT EMT COPPER <br /> SNO. EQUIPMENTS MAX CURRENT OCPD <br /> 10 COMBINER NO. OF MICROINVERTERS IN A STRING X OUTPUT SYSTEM INFO <br /> 1 BOX CURRENT OF MICROINVERTERS X 1.25=MAX 13X1.21X1.25= 19.7A 20A (13)Q CELLS <br /> CURRENT Q.PEAK DUO BILK ML-G10+ <br /> TOTAL NO. OF MICROINVERTERS X OUTPUT (40OW) <br /> 2 MSP CURRENT OF MICROINVERTER X 1.25=MAX 13X1.21X1.25=191A. 20A ( ENPHASE <br /> IQBPLUS-72-2-US(240V) <br /> CURRENT DC SYSTEM SIZE:5.200 kWDC <br /> AC SYSTEM SIZE:3.900 kWAC <br /> REVISIONS <br /> DESCRIPTION DATE REV <br /> TO UTILITY GRID <br /> BRANCH 1 L <br /> 13- Q CELL Q.PEAK DUO BLK ML-G10+ (40OW) MODULES (( 1 BI-DIRECTIONAL UTILITY <br /> \aJ 1-PH,3-W, 120V/240V PROJECT NAME&ADDRESS <br /> Q <br /> N U) <br /> • • • BACK FEED BREAKER AT <br /> (E)MAIN BREAKER TO <br /> PRODUCTION CTS THE OPPOSITE END OF HOUSE,125A/2P,240 V N <br /> THE MAIN BREAKER <br /> O <br /> JUNCTION BOX GATEWAY KNIFE SWITCH + �' �� (E)MAIN SERVICE <br /> 'IV �� Q CABLE — 1 600 V, NEMA 3R, w,,�a AC DISCONNECT: PANEL, <br /> 3-W, pV TED, Z o <br /> l UL LISTED _-=___ I 240V,30A NON-FUSEDW <br /> 2UAJ2p 15A/2P NEMA 3R, UL LISTED J W I- Lo <br /> LU <br /> I u ►, - uu 2 U <br /> (13)ENPHASE I08PLUS-72-2-US(240V)MICROINVERTERS J U Z W 00 <br /> N N - 20A/2P U) W > Lo <br /> T___. <br /> G i0 - I W c/) W O <br /> 2 : ( ir( -�l LL. W W O <br /> (N)ENPHASE IQ 3 4 (; Z Q <br /> COMBINER 4C BOX W W Z <br /> (X-IQ-AM1-240-4C) WIRELESS COM KIT O D- <br /> H <br /> EXISTING GROUND >W <br /> ELECTRODE CONDUCTOR <br /> r <br /> O <br /> Lo <br /> Lo <br /> DATE: 11/4/2022 <br /> SHEET NAME <br /> ELECTRICAL <br /> LINE & CALCS. <br /> SERVICE INFO <br /> UTILITY PROVIDER: SNOPUD SHEET SIZE <br /> MAIN SERVICE VOLTAGE: 240V ANSI B <br /> INTERCONNECTION MAIN SERVICE PANEL: 125 A 11 X 17" <br /> 120% RULE- NEC 705.12(B)(2)(3)(b) MAIN BREAKER RATING: 125 A <br /> UTILITY FEED+SOLAR BACKFEED MAIN SERVICE LOCATION: EAST SHEET NUMBER <br /> 125A+20A= 145A <br /> BUSS RATING X 120% SERVICE FEED SOURCE: OVERHEAD PV-7 <br /> SCALE: NTS 125A x 120% = 150A <br />