Laserfiche WebLink
1 5 • <br /> DISCONNECTTILITY LUM10 <br /> SMARTTO <br /> ENERGY TODAY <br /> ELECTRIC SHOCK HAZARD LABEL LOCATION: (SET) <br /> AC DISCONNECT 1550 DIGITAL DR,LEHI,UT <br /> TERMINALS ON BOTH LINE AND LOAD SIDES MAY PER CODE: NEC 690.56(C)(2) 84043,USA <br /> BE ENERGIZED IN THE OPEN POSITION <br /> LABEL LOCATION: <br /> POINT OF INTERCONNECTION,MAIN SERVICE flPHOTOVOLTAIC AC DISCONNECT <br /> DISCONNECT,AC DISCONNECT,AC COMBINER, <br /> INVERTER IRATED AC OUTPUT CURRENT 15.73 AMPS <br /> PER CODE:NEC 690.13(B) OPERATINGNOMINAL <br /> SYSTEM INFO <br /> LABEL LOCATION: (13)Q CELLS <br /> ACAUTION INTERACTIVE SYSTEM POINT OF INTERCONNECTION Q PEAK DUO BILK ML-G10+ <br /> (400W) <br /> PER CODE:NFPA 70,NEC 690.54 <br /> (13)ENPHASE <br /> IQ8PLUS-72-2-US(240V) <br /> DUAL • _ • DC SYSTEM SIZE:5.200 kWDC <br /> SECOND • 7 URCE IS WARNING AC SYSTEM SIZE:3.900kWAC <br /> PHOTOVOLTAIC INVERTER OUTPUT CONNECTION <br /> DO NOT RELOCATE THIS <br /> OVERCURRENT DEVICE <br /> REVISIONS <br /> LABEL LOCATION: LABEL LOCATION: DESCRIPTION DATE REV <br /> MAIN SERVICE DISCONNECT/AC DISCONNECT/ PLACE THIS LABEL AT P.O.C.TO SERVICE <br /> MAIN SERV CE PANEL/ REVENUE METER/AC DISTRIBUTION EQUIPMENT(I.E.MAIN PANEL <br /> COMBINER (AND SUBPANEL IF APPLICABLE)) <br /> PER CODE:NEC 705.12(C) PER CODE:NEC 705.12(B)(3)(2) <br /> 3 <br /> CAUTION : SOLAR ELECTRIC Q WARNING: PROJECT NAME&ADDRESS <br /> SYSTEM CONNECTED v PHOTOVOLTAIC POWER SOURCE Q <br /> U) <br /> LABEL LOCATION: <br /> LABEL LOCATION: <br /> POINT OF INTERCONNECTION&INVERTER <br /> PER CODE:NEC 690.15&690.13(B) CONDUIT � <br /> PER CODE:NEC 690.31(D)(2) N <br /> 00 <br /> O <br /> 4 SOLAR PV SYSTEM EQUIPPED Q g <br /> WITH RAPID SHUTDOWN 9 CAUTION : SOLAR CIRCUIT w <br /> 0 <br /> 0 <br /> w LO <br /> TURN RAPID LABEL LOCATION: = U 10� p <br /> SHUTDOWN SWITCH MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR CONDUIT,RACEWAYS, U Z w LO <br /> TOTHE'OFF' wLO <br /> ENCLOSURES,AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT,AT TURNS AND > <br /> POSITION TO SHUT SOLAR ELECTRic ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES w "T <br /> DOWN PV SYSTEM PV PANELS PER CODE:IFC 606.11.1.4 w U) O <br /> AND REDUCE LL w w O <br /> SHOTCK EHARRAYD IN Z Q <br /> 10 w z <br /> LABEL LOCATION: Nouser serviceable parts o a <br /> MAIN SERVICE DISCONNECT IF MSDIS OUTSIDE • • • provider ' H <br /> PLACE IT THERE/IF MSD IS INSIDE PLACE ON THE w <br /> AC DISCONNECT LABEL LOCATION: <br /> PER CODE:2020 NEC 690.56(C) INVERTER&JUNCTION BOXES(ROOF) <br /> PER CODE:NEC 690.13(G)(3)&690.13(G)(4) <br /> LO <br /> DATE: 11/4/2022 <br /> SHEET NAME <br /> SIGNAGE <br /> ADHESIVE FASTENED SIGNS SHEET SIZE <br /> • THE LABEL SHALL BE SUITABLE FOR THE <br /> ENVIRONMENT WHERE IT IS INSTALLED. ANSI B <br /> • WHERE REQUIRED ELSEWHERE IN THIS CODE,ALL 11" X 17" <br /> FIELD APPLIED LABELS,WARNING AND MARKINGS <br /> SHOULD COMPLY WITH ANSI 2535.4 [NEC 110.21(B) <br /> FIELD MARKING]. SHEET NUMBER <br /> • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PV-9 <br /> PROPERLY ADHERED.VINYL SIGNS SHALL BE WEATHER <br /> RESISTANT[IFC 605.11.1.31 <br />