Lumio
<br /> SMART ENERGY TODAY
<br /> (SET)
<br /> 1550 DIGITAL DR,LEHI,UT
<br /> Enphase IQ Combiner 4/4C 84043,USA
<br /> MODEL NUMBER
<br /> Enphase Networklnq IQCombiner 4(X-10 AMI-240 4) 10Combiner 4 with Enphuse Q Gate way printed circuit board for nlegrated(evenue grade PV procticlion metering(ANSI
<br /> C12.20+/-0.5X)and consumption monitoring 0/-25%)Includes a silver solar shieid to match the IQ Banery,system and
<br /> IQ System Controller 2 and to deflect heat.
<br /> IQ Combiner 4C(X-IQ AMI-240-4C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production meterin!i
<br /> (ANSI C12.20+1-0.5%)and consumption monitoring(+/-2.5%)Includes Enphase Mobile Connect cellular modem
<br /> (CELLMODEM MI.06-SP-05),a plug-and play Industrial-grade cell modem for systems up to 60 micromvefters. SYSTEM INFO
<br /> (Available In the Us,Canada,Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in
<br /> The Enphasa IQ Combiner 4/4C with Enphase the installation area.)Includes a silver solar shield to match the IQ Battery and IQ System Controller andiode0ectheat (13)QCELLS
<br /> Enphase ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) Q.PEAK DUO BLK ML-G10+
<br /> IQ Gateway and integrated LTE-M1 cell (40OW)
<br /> Q Combiner 4/4 C Ensemble Communications Kit -Includes COMMS-KIT-01 and CELLMODEM•Mt•O6-SP-05 with 5-year Sprint data plan for (13)ENPHASE
<br /> modem (Included only with IQ Combiner 4C) COMMS CELLMODEM MI.06 Ensemble sates
<br /> CELLMODEM-Ml-06-SP-05 -4G based LTE-MI cellular modern with 5-year Sprint data plan I08PLUS-72-2-US(240V)
<br /> X-IQ-AMI-240-4 consolidates interconnection equipment CELLMODEIA MI-06 AT-05 4G based LTE-M1 cellular modem with 5-year AT&T data plan DC SYSTEM SIZE:5.200 kWDC
<br /> X-I A M -240-4 C Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240.BR250,and BR260 circuit breakers AC SYSTEM SIZE:3.900 kWAC
<br /> Q- Into a single enclosure and streamlines 10 BRK-IOA-2-240V Circuit breaker,2 pole.IOA,Eaton BR210
<br /> BRK-15A-2.240V Circuit breaker,2 pole,15A,Eaton BR215
<br /> microinverters and storage installations by BRK-20A-2P-240V Circuit breaker.2 pole,20A.Eaton BR220
<br /> BRK-15A.2P-240V 8 Circuit breaker,2 pole,15A,Eaton BR215B with hold down kit support
<br /> providing a consistent, pre-wired solution for BRK2OA2P-24OVB Circuit breaker,2pole,20A.Eaton BR2208with hold down kit support
<br /> -
<br /> EPLC-01 Power Ilnecarner(communication bridge pair),quantity one pair REVISIONS
<br /> residential applications. It offers up to four
<br /> XA-SOLARSHIELD-ES Replacement solar shield for 10 Combiner 4/4C
<br /> DESCRIPTION DATE REV
<br /> 2 pole input circuits and Eaton BR series )(A-PLUG-120-3 Accessory receptacle for Power Line Carrier in 10 Combiner 4/4C(required for EPLC-01)
<br /> busbar assembly. •,A ENV-PCBA•3 Replacement lO Gateway printed circuit board(PCB)for Combiner 4/4C
<br /> ).10•NA-HD-125A Hold down kit for Eaton circuit breaker with screws. El
<br /> ELECTRICAL SPECIFICATIONS
<br /> Smart Rating Continuous duty PROJECT NAME&ADDRESS
<br /> • Includes IQ Gateway for communication and control `entemvoltage 120/240 VAC,60 Hz
<br /> Includes Enphase Mobile Connect cellular modem Eaton BR renes bulbar rating 125 A U)
<br /> (CELLMODEM M1-06-SP-05),included only with 10 Max continuous current rating 65A
<br /> Combiner 4C MaX.continuous current rating(Input from PV/storage) 64A
<br /> Includes solar shield to match Enphase IQ Battery Max fuse/circuit rating(output) 90A O
<br /> CN
<br /> aesthetics and deflect heat Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) 00
<br /> Flexible networking supports Wi-Fi, Max total branch circuit breaker ratmg Onpul) BOA of distributed generation/95A with IQ Gateway breaker included 0)
<br /> Ethernet,or cellular Production metering CT 200 A solid core pre-installed and wired to 10 Gateway >Q 00
<br /> Optional AC receptacle available for PLC bridge Z
<br /> Provides production metering and consumption Consumption monitoring CT(CT-200-SPLIT) Apair of 200 A split core current transformers W O
<br /> monitoring MECHANICAL DATA __ WI to
<br /> O
<br /> IO W O
<br /> Dimensions(WXH.
<br /> 37.5x49.5x 16.8 cm(14.75'x 19,5'x6.63'),Height is21.06*(53.5cm)with mounting brackets.
<br /> Simple Weight 7.5 kg(16.SIbs) U) LZL.I W to
<br /> p Ambient temperature range •40^C t6+461 C(-401 to 115°F) 0 w
<br /> Centered mounting brackets support single Cooling Natural convection,plus heal shield W C W O
<br /> stud mounting LL WW
<br /> i Enclosure environmental rating Outdoor,Non
<br /> RTL-certified,NEMA type 3R,polycarbonate construction Z •-
<br /> Supports bottom,back and side conduit entry Q :tt
<br /> Up to four 2-pole branch circuits for 240 VAC Wire sizes 20 A to 50 A breaker inputs 14 to 4 AWG copper conductors Z W Z
<br /> •60 A breaker branch input:4 to 1/0 AWG copper conductors W
<br /> plug-in breakers(not included) Main lug combined output:10to2/0AWG copper conductors —7 0Y d
<br /> X-iO-AMl-24U-4C 80A total PV of storage branch circuits Neutral and ground,14 to 1/0 copper conductors 0 Q
<br /> Always follow local code requirements for conductor sizing.
<br /> Altitude To 2000 meters(6,560 feet) w
<br /> Reliable INTERNET CONNECTION OPTIONS
<br /> Durable NRTL-certified NEMA type 3R enclosure Integrated Wl•Fi 802.11b/g/n
<br /> Cellular CELLMODEM-MI.06-SP 05,CELLMODEM-M1-06-AT-05(4G based LTE-Ml cellular modem).Note that an Enphase O
<br /> Five-year limited warranty Mobile Connect cellular modem Is required for all Ensembleinstallatlons. Lr)
<br /> Two years labor reimbursement program coverage
<br /> Ethernet Optional,8023,CatSE(or Cal 6)UTP Ethernet cable(not Included)
<br /> included for both the IQ Combiner SKU's
<br /> UL listed COMPLIANCE DATE: 11/4/2022
<br /> Compliance,IQ Combiner UL 1741,CAN/CSA C22.2 No.107.1.47 CFR,Part 15,Class B,ICES 003
<br /> Production metering:ANSI C12.20 accuracy class 0.5(PV production) SHEET NAME
<br /> Consumption metering:accuracy class 2.5
<br /> OCompliance,10 Gateway UL 60601.1/CANCSA 22.2 No 61010-1 EQUIPMENT
<br /> L
<br /> X-IQ-AMI-2404 LS P E C I F I CATION S
<br /> oleao ENPHASE ENPHASE
<br /> To learn more about Enphase offerings,visit�npF��se corm / To learn more about Enphase offerings,visit epphase.com �-' SHEET SIZE
<br /> 02021 Enphase Bieryy.All o9hls reserved.Enphase,the Enpuase lugu,IU Curribaler 4140 a1C ulher twhesare liat"aaks at ANSI B
<br /> Enphaseaft-t Energy,Inc Oats suto change 1021 2021
<br /> 11rr X 17"
<br /> SHEET NUMBER
<br /> PV-14
<br />
|