SCOPE OF WORK GOVERNING CODES SYSTEM RATING PHOTOVOLTAIC SYSTEM FIRE <br /> TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE CLASSIFICATION LISTING IN Lumi07— <br /> LOCATED AT 5501 WETMORE AVE, EVERETT, WA 98203, USA. 2020 NATIONAL ELECTRICAL CODE 5.200 kWDC ACCORDANCE WITH UL 1703 <br /> THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY 2018 INTERNATIONAL FIRE CODE 3.900 kWAC STANDARD. <br /> GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. 2018 INTERNATIONAL BUILDING CODE SMART ENERGY TODAY <br /> THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. 2018 INTERNATIONAL RESIDENTIAL CODE SHEET INDEX 1550 DIGITAL DR,LEHI,UT <br /> WASHINGTON ADMINISTRATIVE CODE (WAC) PV1 COVER PAGE 84043,USA <br /> EQUIPMENT SUMMARY AHJ NAME : PV2 SITE PLAN <br /> 13 Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES WIRING AND CONDUIT NOTES PV3 ROOF PLAN <br /> 13 ENPHASE IQ8PLUS-72-2-US (240V) MICROINVERTERS • ALL CONDUIT SIZES AND TYPES SHALL BE LISTED FOR ITS PURPOSE AND PV4 STRING LAYOUT&BOM <br /> APPROVAL FOR THE SITE APPLICATIONS <br /> GENERAL NOTES - ALL <br /> ATTACHMENT DETAILS <br /> CABLING <br /> • THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND ALL PV CABLES AND WIRES BE#1 ,USE 2, PV WIRE, OR PV7 ELECTRICAL LINE&CALCS. <br /> OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE PROPRIETARY SOLAR CABLING SPECIFIED BYYAWG MFR, OR EQUIVALENT; ROUTED TO SYSTEM INFO <br /> MODIFICATIONS IN CONSTRUCTION DETAILS. SOURCE CIRCUIT COMBINER BOXES AS REQUIRED PV8 SPECIFICATIONS&NOTES <br /> (13)Q CELLS <br /> • ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE PV9-PV10 SIGNAGE Q.PEAK DUO BILK ML-G10+ <br /> • ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR DERATED ACCORDING TO AS PER LATEST NEC CODE. (40OW) <br /> INSTALLATION OF ANY EQUIPMENT AT SITE. PV11 JOB SAFETY PLAN <br /> EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV (13)ENPHASE <br /> • CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL RESISTANT,AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE PV12-PV21 EQUIPMENT SPECIFICATIONS Q8STEMLUS SI-2-US(0 kW <br /> PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. USED TO PROTECT WIRE FROM SHARP EDGES DC SYSTEM SIZE:5200 kWDC <br /> • CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS • PROJECT SITE • �� • AC SYSTEM SIZE:3.900 kWAC <br /> AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER PHASE AND NEUTRAL CONDUCTORS SHALL T DUAL RATED R 1000 ASP 'J <br /> INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 1000V AS PER <br /> BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION AND APPLICABLE NEC <br /> ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE � <br /> CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER REVISIONS <br /> MEANS DESCRIPTION DATE REV <br /> ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE <br /> COMPENSATION. VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE - <br /> � <br /> • DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, FLOORS, ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION _ii . � l► <br /> CONTRACTOR AT NO ADDITIONAL COST. VOLTAGE DROP LIMITED TO 2% `' r <br /> • THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND AC CONDUCTORS>4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, I ^ <br /> COMPLETION OF THE WORK WITH APPROVED MATERIALS. PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL-WHITE/GRAY "• <br /> • NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE . VOLTAGE DROP LIMITED TO 2% if 'r' I • PROJECT NAME&ADDRESS <br /> ARCHITECT. <br /> • CONTRACTOR SHALL OBTAIN BULDING PERMIT. NO WORK TO START UNLESS BUILDING AC CONDUCTORS>4AWG COLOR CODED OR MARKED: PHASE AOR L1-BLACK, I Q <br /> PERMIT IS PROPERLY DISPLAYED. PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL-WHITE/GRAY U) <br /> • ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE <br /> WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, THE DEPARTMENT OF N <br /> ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. }_ CN <br /> • IT 1 S ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL • ,. <br /> PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. Q o <br /> THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. z c) <br /> • ALL EXPOSED PLUMBING, HVAC, ELECTRICAL DUCTWORK, PIPING AND CONDUITS ARE TO _ _ o <br /> BE PAINTED BY GENERAL CONTRACTOR. ( M4 Data I Terms of Use ' Report a map error J W w LO <br /> • THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE HOUSE PHOTO SCALE:NTS U z W 00 <br /> LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. U) W > rn <br /> • THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS, PROJECT SITE 0' 0 W <br /> ETC.AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. LL w LLI o <br /> • CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK. Z Q <br /> cn Z <br /> Lu W Z <br /> ELECTRICAL NOTESa � 0_ <br /> • ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. >✓ <br /> • ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET `D <br /> ENVIRONMENT. on G LA C I E F _W Lowell Rive W <br /> • WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY a <br /> TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. ng Q 7 �• o <br /> • WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL -0 Q U-) <br /> COMPLY WITH NEC 110.26. <br /> U /4/2022 <br /> • WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, THE DATE: 11 <br /> CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br /> SHEET NAME <br /> • ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br /> • MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE COVER PAGE <br /> SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. <br /> • MODULE SUPPORT RAIL SHALL BE BONDED TO THE MODULE SHEET SIZE <br /> 0 ANSI B <br /> Cp�iN9peata Terms of Use Report a map error 1 1° X 17" <br /> VICINITY MAP SCALE:NTS <br /> SHEET NUMBER <br /> PV-1 <br />