My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1216 BROADWAY 2023-05-25
>
Address Records
>
BROADWAY
>
1216
>
1216 BROADWAY 2023-05-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/25/2023 7:53:23 AM
Creation date
5/25/2023 7:32:09 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
1216
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table V-A.S: Maintenance Standards - Catch Basins <br />Maintenance <br />Defect <br />Conditions When Maintenance Is Needed <br />Results Expected When Maintenance Is per - <br />Component <br />formed <br />Trash or debris which is located immediately in front of the catch basin opening or is blocking inietting capacity of the basin by more than 10%. <br />No Trash or debris located immediately in front of <br />Trash or debris (in the basin) that exceeds 60 percent of the sump depth as measured from the bottom of basin to Invert of the lowest pipe Into or out of the <br />catch basin or on grate opening. <br />basin, but in no case less than a minimum of six inches clearance from the debris surface to the invert of the lowest pipe. <br />No trash or debris in the catch basin. <br />Trash & Debris <br />Trash or debris in an inlet or outlet i blocking more than 1/3 of its height. Y pipe 9 9 <br />Inlet and outlet pipes free of trash or debris. <br />Dead animals or vegetation that could generate odors that could cause complaints or dangerous gases (e.g., methane). <br />No dead animals or vegetation present within the <br />catch basin. <br />Sediment Qn the basin) that exceeds 60 percent of the sump depth as measured from the bottom of basin to invert of the lowest pipe into or out of the <br />Sediment <br />basin, but in no case less than a minimum of 6 inches clearance from the sediment surface to the invert of the lowest pipe. <br />No sediment in the catch basin <br />General <br />Structure Damage to <br />T slab has holes larger than 2 square inches or cracks wider than 1/4 inch. Intent is to make sure no material is running into basin). <br />Top r9 q ( 9 ) <br />Top slab is free of holes and cracks. <br />Frame and/or Top Slab <br />Frame not silting flush on top slab, i.e., separation of more than 314 inch of the frame from the top slab. Frame not securely attached <br />Frame is sitting flush on the riser rings ortop slab <br />and firmly attached. <br />Fractures or Cracks in <br />Maintenance person judges that structure is unsound. <br />Basin replaced or repaired to design standards. <br />Basin Walk/ Bottom <br />Grout fillet has separated or cracked wider than 1/2 inch and longer than 1 foot at the joint of any inlet/outlet pipe or any evidence of soil particles entering <br />Pipe is regrouted and secure at basin wall. <br />catch basin through cracks. <br />Settlement/ Mis- <br />If failure of basin has created a safety, function, or design problem. <br />Basin replaced or repaired to design standards. <br />alignment <br />Vegetation growing across and blocking more than 10% of the basin opening. <br />No vegetation blocking opening to basin. <br />Vegetation <br />Vegetation growing in inlet/outlet pipe joints that is more than six inches tall and less than six inches apart. <br />No vegetation or root growth present. <br />Contamination and Po{. <br />See 7ablo V-A 1 Mainterance Standards - Detention Ponds <br />No pollution <br />Po Present. <br />lotion— <br />Cover Not in Place <br />Cover is missing or only partially in place. Any open catch basin requires maintenance. <br />Cover/grate is in place, meets design standards, <br />and is secured <br />Catch Basin <br />Locking Mechanism <br />Mechanism cannot be opened by one maintenance person with propertook. Bolls into frame have less than 1/2 inch of thread. <br />Mechanism opens with proper took. <br />Cover <br />Not Working <br />Cover Difficult to <br />One maintenance person cannot remove lid after applying normal lifting pressure. <br />Cover can be removed by one maintenance per. <br />Remove <br />(Intent is keep cover from sealing off access to maintenance.) <br />son. <br />Ladder <br />Ladder Rungs Unsafe <br />Ladder is unsafe due to missing rungs, not securely attached to basin wall, misalignment, rust, cracks, or sharp edges. <br />Ladder meets design standards and allows main- <br />tenance person safe access. <br />Grate opening Unsafe <br />Grate with opening wider than 7/8 inch. <br />Grate opening meets design standards. <br />Metal Grates <br />Trash and Debris <br />Trash and debris that is blocking more than 20% of grate surface insetting capacity. <br />Grate free of trash and debris. <br />(If Applicable) <br />Grate is in place, meets the design standards, and <br />Damaged or Missing. <br />Grate missing or broken members) of the grate. <br />is Installed and aligned with the flow path. <br />2019 Stormwater Management Manual for Western Washington <br />Volume V - Appendix A - Page 1009 <br />
The URL can be used to link to this page
Your browser does not support the video tag.