10312 EVERGREEN WAY SONIC Geotech Report 2023-05-25
>
Address Records
>
EVERGREEN WAY
>
10312
>
SONIC
>
Geotech Report
>
10312 EVERGREEN WAY SONIC Geotech Report 2023-05-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/25/2023 1:47:29 PM
Creation date
5/25/2023 1:45:46 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10312
Tenant Name
SONIC
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Geotechnical Engineering Report 10 January 8,2021 <br /> Glint Car Wash and Sonic Everett,Everett,Washington RGI Project No.2020-643-1 <br /> Table 5 Retaining Wall Design <br /> Design Parameter Value <br /> Allowable Bearing Capacity—Native soil or <br /> structural fill 2,500 psf <br /> Active Earth Pressure (unrestrained walls) 35 pcf <br /> At-rest Earth Pressure (restrained walls) 50 pcf <br /> For seismic design, an additional uniform load of 7 times the wall height (H) for <br /> unrestrained walls and 14H for restrained walls should be applied to the wall surface. <br /> Friction at the base of foundations and passive earth pressure will provide resistance to <br /> these lateral loads.Values for these parameters are provided in the Section 5.3. <br /> 5.5 SLAB-ON-GRADE CONSTRUCTION <br /> Once site preparation has been completed as described in Section 5.2, slab-on-grade <br /> construction can be supported on 12 inches of structural fill. Immediately below the floor <br /> slab, RGI recommends placing a 4-inch-thick capillary break layer of clean, free-draining <br /> pea gravel, washed rock, or crushed rock that has less than 5 percent passing the U.S. No. <br /> 200 sieve.This material will reduce the potential for upward capillary movement of water <br /> through the underlying soil and subsequent wetting of the floor slab. Where moisture by <br /> vapor transmission is undesirable, an 8- to 10-mil-thick plastic membrane should be <br /> placed on a 4-inch-thick layer of clean gravel or rock. <br /> For the anticipated floor slab loading, we estimate post-construction floor settlements of <br /> 'A- to 'A-inch. For thickness design of the slab subjected to point loading from storage <br /> racks, RGI recommends using a subgrade modulus (Ks) of 150 pounds per square inch per <br /> inch of deflection. <br /> If the buildings will be supported on reinforced slab with thicken edges, a soil bearing <br /> capacity of 1,000 pound per square feet (psf) and subgrade modulus of 150 pound per <br /> cubic inch (pci) can be used for the concrete slab design. For the anticipated floor slab <br /> loading,we estimate post-construction floor settlements of'A-to%-inch <br /> 5.6 DRAINAGE <br /> 5.6.1 SURFACE <br /> Final exterior grades should promote free and positive drainage away from the building <br /> area. Water must not be allowed to pond or collect adjacent to foundations or within the <br /> immediate building area. For non-pavement locations, RGI recommends providing a <br /> minimum drainage gradient of 3 percent for a minimum distance of 10 feet from the <br /> Corporate Office <br /> 17522 Bothell Way Northeast <br /> Bothell,Washington 98011 <br /> Phone 425.415.0551• Fax 425.415.0311 <br /> 414 4'.riley-group.com <br />