Geotechnical Engineering Report 10 January 8,2021 <br /> Glint Car Wash and Sonic Everett,Everett,Washington RGI Project No.2020-643-1 <br /> Table 5 Retaining Wall Design <br /> Design Parameter Value <br /> Allowable Bearing Capacity—Native soil or <br /> structural fill 2,500 psf <br /> Active Earth Pressure (unrestrained walls) 35 pcf <br /> At-rest Earth Pressure (restrained walls) 50 pcf <br /> For seismic design, an additional uniform load of 7 times the wall height (H) for <br /> unrestrained walls and 14H for restrained walls should be applied to the wall surface. <br /> Friction at the base of foundations and passive earth pressure will provide resistance to <br /> these lateral loads.Values for these parameters are provided in the Section 5.3. <br /> 5.5 SLAB-ON-GRADE CONSTRUCTION <br /> Once site preparation has been completed as described in Section 5.2, slab-on-grade <br /> construction can be supported on 12 inches of structural fill. Immediately below the floor <br /> slab, RGI recommends placing a 4-inch-thick capillary break layer of clean, free-draining <br /> pea gravel, washed rock, or crushed rock that has less than 5 percent passing the U.S. No. <br /> 200 sieve.This material will reduce the potential for upward capillary movement of water <br /> through the underlying soil and subsequent wetting of the floor slab. Where moisture by <br /> vapor transmission is undesirable, an 8- to 10-mil-thick plastic membrane should be <br /> placed on a 4-inch-thick layer of clean gravel or rock. <br /> For the anticipated floor slab loading, we estimate post-construction floor settlements of <br /> 'A- to 'A-inch. For thickness design of the slab subjected to point loading from storage <br /> racks, RGI recommends using a subgrade modulus (Ks) of 150 pounds per square inch per <br /> inch of deflection. <br /> If the buildings will be supported on reinforced slab with thicken edges, a soil bearing <br /> capacity of 1,000 pound per square feet (psf) and subgrade modulus of 150 pound per <br /> cubic inch (pci) can be used for the concrete slab design. For the anticipated floor slab <br /> loading,we estimate post-construction floor settlements of'A-to%-inch <br /> 5.6 DRAINAGE <br /> 5.6.1 SURFACE <br /> Final exterior grades should promote free and positive drainage away from the building <br /> area. Water must not be allowed to pond or collect adjacent to foundations or within the <br /> immediate building area. For non-pavement locations, RGI recommends providing a <br /> minimum drainage gradient of 3 percent for a minimum distance of 10 feet from the <br /> Corporate Office <br /> 17522 Bothell Way Northeast <br /> Bothell,Washington 98011 <br /> Phone 425.415.0551• Fax 425.415.0311 <br /> 414 4'.riley-group.com <br />