My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3722 ROCKEFELLER AVE 2023-06-27
>
Address Records
>
ROCKEFELLER AVE
>
3722
>
3722 ROCKEFELLER AVE 2023-06-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/27/2023 9:17:40 AM
Creation date
5/30/2023 6:26:27 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3722
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SOLAR MODULE SPECIFICATIONS &TX*VlE�ljQNdA&k <br /> MANUFACTURER/MODEL Q CELLS Q.PEAK DUO BLK ML-G10+ (40oW) Lumio <br /> VMP 37.13 V R BRANCH CIRCUIT #1 OF 12 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.65% SMART ENERGYTODAY <br /> IMP 10.77 A F R BRANCH CIRCUIT #2 OF 9 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.38% (SET) <br /> 1550 DIGITAL DR,LEHI,UT <br /> VOC 45.3 V F R BRANCH CIRCUIT #3 OF 6 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.18% 84043,USA <br /> ISC 11.14A LTAGE RISE FROM THE JUNCTION BOX 1 TO THE IQ COMBINER BOX 4C <br /> TEMP. COEFF.VOC -0.27%/K ISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br /> PTC RATING 376.55 W - 1.21 AMP X 12) X (0.00129 OHMS/FT) X (30 FT X 2) <br /> MODULE DIMENSION I 74"(L)x 41.1"(W) <br /> PANEL WATTAGE 40o w - 4.52 AMPS X 0.00129 OHMS/FT) X 60 FT SYSTEMINFO <br /> 12 VOLTS (27)Q CELLS <br /> INVERTER SPECIFICATIONS °/ RISE - 1.12 VOLTS = 240 VOLTS - 0.47% Q.PEAK DUO BLK ML-G10+ <br /> MANUFACTURER/MODEL ENPHASE IQ8PLUS-72-2-US (240V) ° (40oW) <br /> THE VOLTAGE RISE FROM THE JUNCTION BOX 1 TO THE IQ COMBINER BOX 4C IS 0.47% (27)ENPHASE <br /> MAX DC SHORT CIRCUIT CURRENT 15 A IQ8PLUS-72-2-US(240V) <br /> CONTINUOUS OUTPUT CURRENT 1.21 A LTAGE RISE FROM THE IQ COMBINER BOX 4C TO THE NF AC DISCONNECT 1 DC SYSTEM SIZE:10.800kWDC <br /> AC SYSTEM SIZE:8.100 kWAC <br /> AMBIENT TEMPERATURE SPECS ISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) <br /> RECORD LOW TEMP -5°C - 1.21 AMP X 27) X (0.00051 OHMS/FT) X (5 FT X 2) <br /> AMBIENT TEMP (HIGH TEMP 2%) 26°C = 2.67 AMPS X 0.00051 OHMS/FT) X 10 FT REVISIONS <br /> CONDUIT HEIGHT 7/8" _ .17 VOLTS DESCRIPTION DATE REV <br /> ROOF TOP TEMP 90°C %VRISE = 0.17 VOLTS = 240 VOLTS = 0.07% REVISION 12/15/2022 A <br /> CONDUCTOR TEMPERATURE RATE 48°C THE VOLTAGE RISE FROM THE IQ COMBINER BOX 4C TO THE NON FUSED AC DISCONNECT IS 0.07% REVISION 12/19/2022 B <br /> MODULE TEMPERATURE COEFFICIENT OF VOC -0.27%/K LTAGE RISE FROM THE NF AC DISCONNECT 1 TO THE NF AC DISCONNECT 2 REVISION 02/08/2023 C <br /> PERCENT OF VALUES NUMBER OF CURRENT CARRYING ISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) PROJECT NAME&ADDRESS <br /> CONDUCTORS IN EMT <br /> 1.21 AMP X 27) X (0.00051 OHMS/FT) X (24 FT X 2) <br /> 0.80 4-6 _ <br /> 0.70 7-9 = 2.67 AMPS X 0.00051 OHMS/FT) X 48 FT N <br /> 0.50 10-20 = 80 VOLTS m <br /> %VRISE = 0.80 VOLTS = 240 VOLTS = 0.33% < <br /> THE VOLTAGE RISE FROM THE NON FUSED AC DISCONNECT TO THE NON FUSED AC DISCONNECT IS 0.33% _ <br /> LTAGE RISE FROM THE NF AC DISCONNECT 2 TO THE FUSED AC DISCONNECT w <br /> VRISE ISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) L w > N <br /> CHANGED = 1.21 AMP X 27) X (0.00051 OHMS/FT) X (47 FTX 2) p z w rn <br /> = 2.67 AMPS X 0.00051 OHMS/FT X 94 FT w Lu Q 00 <br /> = 1.57 VOLTS ) = o Q CD <br /> %VRISE = 1.57 VOLTS = 240 VOLTS = 0.65% d � w <br /> 1 4t <br /> HE VOLTAGE RISE FROM THE NON FUSED AC DISCONNECT TO THE FUSED AC DISCONNECT IS 0.65% w Z <br /> V LTAGE RISE FROM THE FUSED AC DISCONNECT TO THE MSP w Q <br /> ISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT.) o <br /> = 1.21 AMP X 27) X (0.00051 OHMS/FT) X (5 FT X 2) 0� <br /> = 2.67 AMPS X 0.00051 OHMS/FT) X 10 FT N <br /> = .17 VOLTS c i <br /> %VRISE = 0.17 VOLTS = 240 VOLTS = 0.07% <br /> DATE:2/8/2023 <br /> HE VOLTAGE RISE FROM THE FUSED AC DISCONNECT TO THE MSP IS 0.07% <br /> SHEET NAME <br /> TAIL SYSTEM VOLTAGE RISE FOR ALL WIRE SECTIONS 0000 SPECIFICATIONS <br /> .65% + 0.47% + 0.07% + 0.33% + 0.65% + 0.07% = 2.24% & NOTES <br /> SHEET SIZE <br /> ANSI B <br /> 11" X 17" <br /> SHEET NUMBER <br /> PV-8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.