Laserfiche WebLink
r r <br /> i r <br /> WoodWorks® Shearwalls Youngblut.wsw Jun. 10, 2021 16:51:09 <br /> Structural Data <br /> STORY INFORMATION <br /> Story Floor/Ceiling Wall <br /> Elev[ft] Depth[in] Height[ft] <br /> Ceiling 18.8 3 0!ion] <br /> Level2 L0.83 10.0 8.00 <br /> Level1 2.00 0.0 8.00 <br /> Foundation 2.00 <br /> SHEATHING MATERIALS by WALL GROUP <br /> Sheathing Fasteners Apply <br /> Grp Surf Material Ratng Thick GU Ply Or Gvtv Size Type Df Eg Fd Bk Notes <br /> in in Ibs/in in in <br /> 1 Ext Struct Sh OSB 32/16 15/32 - - Vert 83500 8d Nail N 2 12 Y 2 --''�e-c•' <br /> 2 Ext Struct Sh OSB 32/16 15/32 - - Vert 83500 8d Nail N 6 12 Y <br /> Legend: <br /> Grp-Wall Design Group number,used to reference wall in other tables(created by program) <br /> Surf-Exterior or interior surface when applied to exterior wall <br /> Ratng-Span rating, see SDPWS Table C4.2.2.2C <br /> Thick-Nominal panel thickness <br /> GU-Gypsum underlay thickness <br /> Ply-Number of plies(or layers)in construction of plywood sheets <br /> Or-Orientation of longer dimension of sheathing panels <br /> Gvtv-Shear stiffness in lb/in.of depth from SDPWS Tables C4.2.2A-B <br /> Type-Fastener type from SDPWS Tables 4.3A-D:Nail-common wire nail for structural panels and lumber,cooler or gypsum wallboard nail for GWB, <br /> plasterboard nail for gypsum lath,galvanised nail for gypsum sheathing; Box-box nail;Casing-casing nail;Roof-roofing nail;Screw-drywall screw <br /> Size-Common,box,and casing nails:refer to SDPWS Table Al(casing sizes=box sizes). <br /> Gauges: 11 ga=0.120"x 1-3/4"(gypsum sheathing,25/32"fiberboard), 1-1/2"(lath&plaster, 1/2"fiberboard); 13 ga plasterboard=0.92"x 1-1/8". <br /> Cooler or gypsum wallboard nail:5d=.086"x 1-5/8';6d=.092"x 1-7/8';8d=.113"x 2-3/8';6/8d=6d base ply,8d face ply for 2-ply GWB. <br /> Drywall screws:No. 6, 1-1/4"long. <br /> 5/8" gypsum sheathing can also use 6d cooler or GWB nail <br /> Of-Deformed nails(threaded or spiral), with increased withdrawal capacity <br /> Eg- Panel edge fastener spacing <br /> Fd- Field spacing interior to panels <br /> Bk-Sheathing is nailed to blocking at all panel edges;Y(es)or N(o) <br /> Apply Notes-Notes below table legend which apply to sheathing side <br /> Notes: <br /> 2.Framing at adjoining panel edges must be 3"nominal or wider with staggered nailing according to SDPWS 4.3.7.1.4 <br /> FRAMING MATERIALS and STANDARD WALL by WALL GROUP <br /> Wall Species Grade b d Spcg SG E Standard Wall <br /> Grp in in in psi^6 <br /> 1 D.Fir-L Stud 1.50 5.50 16 0.50 1.40 <br /> 2 D.Fir-L Stud 1.50 5.50 16 _ 0.50 1.40 <br /> Legend: <br /> Wall Grp-Wall Design Group <br /> b-Stud breadth(thickness) <br /> d-Stud depth(width) <br /> Spcg-Maximum on-centre spacing of studs for design,actual spacing may be less. <br /> SG-Specific gravity <br /> E-Modulus of elasticity <br /> Standard Wall-Standard wall designed as group. <br /> Notes: <br /> Check manufacture requirements for stud size,grade and specific gravity(G)for all shearwall hold-downs. <br /> 2 <br />