Laserfiche WebLink
• <br /> WoodWorks® Shearwalls Youngblut.wsw Jun. 10, 2021 16:51:09 <br /> Flexible Diaphragm Wind Design <br /> ASCE 7 Directional(All Heights)Loads 11 <br /> O/rcr &O✓4 5 v <br /> SHEAR RESULTS <br /> N-S W For ASD Shear Force[pH] Asp-Cub Allowable Shear[pit] ' Resp. <br /> Shearlines Gp Dir v vmax/vft V[Ibs] , Int Ext Int Ext Co C Cmb V[Ibs] Ratio <br /> Line 1 <br /> Level 2 <br /> Lni, Lev2 2 Both 52.0 52.0 1248 - 1.0 - 364 1.00 364 8736 0.14 <br /> Level 1 <br /> Lnl, Levl 2 Both 50.1 50.1 1702 - 1.0 - 364 1.00 364 12376 0.14 <br /> Line 2 <br /> Ln2, Levi Both 219.9 219.9 1429 - 1.0 - 364 1.00 364 2366 0.eO <br /> Line 4 <br /> Level 2 <br /> Ln4, Lev2 2 Both 60.1 60.1 1248 - 1.0 - 364 1.00 364 '7553 0.17 <br /> Level 1 <br /> Ln4, Levi 7 Both 89.8 89.8 2223 - 1.0 - 364 1.00 364 9009 0.25 <br /> E-W W For ASD Shear Force[plf] Asp-Cub Allowable Shear[pit] Resp. <br /> Shearlines Gp Dir v vmax/vft V[Ibs] Int Ext Int Ext Co C Cmb V Epps] _ Ratio <br /> Line A <br /> Level 1 <br /> LnA, Levl - Both - - 597 - - - - - - 3640 - <br /> Wall A-1 2 Both 59.7 59.7 597 - 1.0 - 364 1.00 364 3640 0.16 <br /> Wall A-2 1 Both 0.0 0 - 1.0 - 896 0.33 299 - - <br /> Line B <br /> Level 2 <br /> LnB, Lev2 2 Both 54.1 102.5 802 - 1.0 - 364 0.53 192 2849 0.28S <br /> Level 1 <br /> LnB, Levi - Both - -• 2414 - - - - - - 9681 - <br /> W'all B-1 2 Both 88.5 88.5 885 - 1.0 - 364 1.00 3E4 3640 0.24 <br /> Wall 5-:' Both 63.1 108.3 335 - 1.0 - 364 0.58 212 1127 0.30 <br /> Wall B-3 Both 88.5 88.5 1194 - 1.0 - 364 1.00 364 4914 0.24 <br /> Line C <br /> Level 2 <br /> LnC, Lev2 2 Both 44.8 49.7 795 - 1.0 - 364 0.90 328 5821 0.14S <br /> Level 1 <br /> LnC, Levi 2^ Both 362.5 362.5 1813 - 1.0 - 364 1.00 364 1820 1.00 <br /> Legend: <br /> W Gp-Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^"means that this wall is critical for <br /> all walls in the Standard Wall group. <br /> For Dir-Direction of wind force along shearline. <br /> v-Design shear force on segment=ASD-factored shear force per unit length of full-height sheathing(FHS) <br /> vmax/vft-Perforated walls:Collector and in-plane anchorage force as per SDPWS eqn.4.3-9=V/FHS/Co. FHS is factored for narrow segments as per <br /> 4.3.4.3 <br /> Force-transfer walls:Shear force in piers above and below either openings or piers beside opening(s).Aspect ratio factor does not apply to these piers. <br /> V-ASD factored shear force. For shearlme:total shearline force.For wall:total of all segments on wall.For segment:force on segment <br /> Asp/Cub-For wall:Unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. For segment or force-transfer pier:Aspect ratio adjustment from <br /> SDPWS 4.3.3.4.1 <br /> Int-Unit shear capacity of interior sheathing:Ext-Unit shear capacity of exterior sheathing. For wall:Unfactored. For segment:Include Cub factor and <br /> aspect ratio adjustments. <br /> Co-Adjustment factor for perforated walls from SDPWS Table 4.3.3.5. <br /> C-Sheathing combination rule,A=Add capacities, S=Strongest side or twice weakest, G=Stiffness-based using SDPWS 4.3-3. <br /> Cmb-Combined interior and exterior unit shear capacity including perforated wall factor Co. <br /> V-Total factored shear capacity of shearline, wall or segment. <br /> Crit Resp-Response ratio=v/Cmb=design shear force/unit shear capacity. "S"indicates that the wind design criterion was critical in selecting wall. <br /> Notes: <br /> Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4. <br /> 7 <br />