My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2119 LOMBARD AVE 2023-05-30
>
Address Records
>
LOMBARD AVE
>
2119
>
2119 LOMBARD AVE 2023-05-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2023 3:30:17 PM
Creation date
5/30/2023 3:28:03 PM
Metadata
Fields
Template:
Address Document
Street Name
LOMBARD AVE
Street Number
2119
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WoodWorks® Shearwalls Youngblut.wsw Jun. 10, 2021 16:51:09 <br /> SHEAR RESULTS(flexible seismic design) <br /> N-S W For ASD Shear Force[pH] Asp-Cub Allowable Shear[pit] Resp. <br /> Shearlines Gp Dir v vmax/vft V[Ibs] Int Ext Int Ext Co C Cmb V[Ibs] Ratio <br /> Line 1 <br /> Level 2 <br /> Lnl, Lev2 2 Both 32.3 32.3 776 - 1.0 - 260 1.00 260 6240 0.12W <br /> Level 1 <br /> Lnl, Levl 2 Both 31.5 31.5 1072 - 1.0 - 260 .1.00 260 8840 0.12W <br /> Line 2 <br /> Ln2, Levl 2 Both 72.3 72.3 470 - 1.0 - 260 1.00 260 1690 0.28W <br /> Line 4 <br /> Level 2 <br /> Ln4, Lev2 2 Both 37.4 37.4 776 - 1.0 - 260 :1.00 260 5395 0.14W <br /> Level 1 <br /> Ln4, Levl 2 Both 48.4 48.4 1199 - 1.0 - 260 1.00 260 6435 0.19W <br /> E-W W For ASD Shear Force[plf] Asp-Cub Allowable Shear[pH] Resp. <br /> Shearlines Gp Dir v vmax/vft V[Ibs] Int Ext Int Ext Co C Cmb V[Ibs] Ratio <br /> Line A <br /> Level 1 <br /> LnA, Levl - }3ot.h - - 203 - - - - - - 2600 - <br /> Wall A-1 2 Both 20.3 20.3 203 - 1.0 - 260 1.00 260 2600 0.08W <br /> Wall A-2 1 Both 0.0 0 - 1.0 - 640 0.33 213 -- - <br /> Line B <br /> Level 2 <br /> LnB, Lev2 2 Both 52.7 99.8 781 - 1.0 - 260 0.53 137 2035 0.38 <br /> Level 1 <br /> LnB, Levl - Both - -, 1340 - - - - - - 6915 - <br /> Wall B-1 2 Both 49.1 49.1 491 - 1.0 - 260 1.30 260 2600 0.19W <br /> Wall B-2 2 Both 35.0 60.1 186 - 1.0 - 260 0.58 151 805 0.23W <br /> Wall B-3 2 Both 49.1 49.1 663 - 1.0 - 260 1.00 260 3510 0.19W <br /> Line C <br /> Level 2 <br /> LnC, Lev2 2 Both 43.4 48.2 771 - 1.0 - 260 0.90 234 4158 0.19 <br /> Level 1 <br /> LnC, Levi 2 Both 239.7 239.7 1198 - 1.0 - 260 1.00 260 1300 0.92W <br /> Legend: <br /> W Gp-Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^"means that this wall is critical for <br /> all walls in the Standard Wall group. <br /> For Dir-Direction of seismic force along shearline. <br /> v-Design shear force on segment=ASD-factored shear force per unit length of full-height sheathing(FHS) <br /> vmax/vft-Perforated walls:Collector and in-plane anchorage force as per SDPWS eqn. 4.3-9=V/FHS/Co.FHS is factored for narrow segments as per <br /> 4.3.4.3 <br /> Force-transfer walls:Shear force in piers above and below either openings or piers beside opening(s).Aspect ratio factor does not apply to these piers. <br /> V-ASD factored shear force.For shearline:total shearline force. For wall:total of all segments on wall.For segment:force on segment <br /> Asp/Cub-For wall:Unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. For segment or force-transfer pier:Aspect ratio adjustment from <br /> SDPWS 4.3.3.4.1 <br /> Int-Unit shear capacity of interior sheathing;Ext-Unit shear capacity of exterior sheathing. For wall:Unfactored.For segment:Include Cub factor and <br /> aspect ratio adjustments. <br /> Co-Adjustment factor for perforated walls from SDPWS Table 4.3.3.5. <br /> C-Sheathing combination rule,A=Add capacities, S=Strongest side or twice weakest, G=Stiffness-based using SDPWS 4.3-3. <br /> Cmb-Combined interior and exterior unit shear capacity including perforated wall factor Co. <br /> V-Total factored shear capacity of shearline,wall or segment. <br /> Crit Resp-Response ratio=v/Cmb=design shear force/unit shear capacity. 'W"indicates that the wind design criterion was critical in selecting wall. <br /> Notes: <br /> Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4. <br /> 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.