My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2119 LOMBARD AVE 2023-05-30
>
Address Records
>
LOMBARD AVE
>
2119
>
2119 LOMBARD AVE 2023-05-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2023 3:30:17 PM
Creation date
5/30/2023 3:28:03 PM
Metadata
Fields
Template:
Address Document
Street Name
LOMBARD AVE
Street Number
2119
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WoodWorks® Shearwalls Youngblut.wsw Jun. 10, 2021 16:51:09 <br /> HOLD-DOWN DESIGN(flexible seismic design,continued) <br /> C-1 R End 32.88 35.00 45 <br /> Legend: <br /> Line-Wall: <br /> At wall or opening-Shearline and wall number <br /> At vertical element-Shearline <br /> Posit'n- Position of stud that hold-down is attached to: <br /> V Elem- Vertical element:column or strengthened studs required where not at wall end or opening <br /> L or R End-At left or right wall end <br /> L or R Op n- At left or right side of opening n <br /> t @ Op n- Uplift force t at opening n from offset opening in perforated wall above,from SDPWS 4.3.6.2.1 <br /> Location-Co-ordinates in Plan View <br /> Hold-down Forces: <br /> Shear-Seismic shear overturning component, factored for ASD by 0.7.For perforated walls, T from SDPWS 4.3-8 is used <br /> Dead-Dead load resisting component,factored for ASD by 0.60 <br /> Ev-Vertical seismic load effect from ASCE 7 12.4.2.2=-0.2Sds x ASD seismic factor x unfactored D=0.149 x factored D.Refer to Seismic Information <br /> table for more details. <br /> Cmb'd-Sum of ASD-factored overturning,dead and vertical seismic forces. May also include the uplift force t from perforated walls from SDPWS <br /> 4.3.6.2.1 when openings are staggered. <br /> Hold-down-Device used from hold-down database <br /> Cap-Allowable ASD tension load <br /> Crit. Resp.-Critical Response=Combined ASD force/Allowable ASD tension load <br /> Notes: <br /> 1/2 AB for studs with thickness>0'-1.5": 1650 tension allowable per anchor bolt. Assume 2 per segmented wall <br /> Combined force from ASCE 7 2.4.1 load combination 10=-(0.6D-0.7Ev+0.7Eh);Eh(from 12.4.2.1)=-shear overturning force <br /> Refer to Shear Results table for factor Co,and shearline dimensions table for the sum of Li,used to calculate tension force T for perforated walls from <br /> SDPWS Eqn.4.3-8. <br /> Designer is responsible for design of connection from wall to floor or foundation for shear force shown in Shear Results table.Refer to SDPWS 4.3.6.4.3 for <br /> foundation anchor bolt requirements. <br /> 13 <br />