Laserfiche WebLink
1 <br /> Lighting, Motor, and Electrical Permit Checklist, Pg. 3 LTG-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised Nov 2017 <br /> Project Title: Sea Mar Everett Clinic !Date 4/8/2020 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents _ Documents Notes <br /> INTERIOR LIGHTING POWER&EFFICACY <br /> Include all luminaires in lighting fixture schedule;indicate fixture <br /> types,lamps,ballasts,and manufacturer's rated watts per AE1.01 <br /> fixture; <br /> Identify spaces eligible for lighting power exemption on plans <br /> Yes C405.4.1 Total connected and in compliance forms;indicate the exception applied; <br /> C405.4.2 interior lighting power Identify lighting equipment eligible for lighting power exemption <br /> in fixture schedule and in compliance forms;indicate the <br /> exception applied; _ <br /> Indicate that exempt lighting equipment is in addition to general <br /> area lighting and is controlled independently <br /> Yes C405.3 Exit signs Indicate location of exit signs on plans and rated watts per A0.01 <br /> fixture in lighting fixture schedule(maximum 5 watts per side) <br /> If high efficacy exception is applied to permanently installed <br /> Lighting in dwelling lighting fixtures in dwelling units,indicate in lighting fixture <br /> NA C405.1 units-lamp efficacy schedule if lamps in fixtures are high efficacy per R404.1. <br /> Calculate percentage of fixtures with high efficacy lamps in <br /> project(min 75%to comply with exception). <br /> Interior Lighting Power Calculation-Indicate compliance path taken <br /> Building Area Complete required compliance forms—proposed wattage per <br /> Yes C405.4.2.1 Method building area does not exceed maximum allowed wattage per AE1.01 <br /> building area;identify locations of building areas on plans <br /> Complete required compliance forms—total proposed wattage <br /> Space-By-Space does not exceed maximum allowed wattage;identify locations o <br /> Yes C405.4.2.2 AE1.01 <br /> Method space types on plans,induding retail display areas,lobby art& <br /> exhibit display areas,and ceiling heights as applicable <br /> ADDITIONAL EFFICIENCY PACKAGE OPTION-REDUCED INTERIOR LIGHTING POWER DENSITY <br /> To comply with additional efficiency package option, <br /> Reduced lighting demonstrate in compliance forms that total connected interior <br /> Yes C406.3 power density lighting wattage is 25/o less than the total maximum allowed A2.07;AE1.01 <br /> lighting wattage via Building Area Method or Space-By-Space <br /> Method <br /> Reduced lighting For project with dwelling units,to comply with additional <br /> power density- efficiency package option indicate in lighting fixture schedule if <br /> NA C406.3 dwelling unit lamp lamps in interior fixtures have efficacy rating of 60 lumens per <br /> efficacy watt or more.Calculate percentage of fixtures with lamps that <br /> have this efficacy rating(min 95%to comply with option) <br /> EXTERIOR LIGHTING POWER&EFFICACY <br /> Include all luminaires in lighting fixture schedule;indicate fixture <br /> types,lamps,ballasts,and manufacturer's rated watts per AE1.01 <br /> fixture; ___ _ <br /> Total connected Identify exterior applications eligible for lighting power <br /> Yes C405.5.2 exterior lighting exemption on plans and in compliance forms;indicate exception <br /> power applied; <br /> Indicate that exempt exterior lighting is controlled independently <br /> from non-exempt exterior lighting;include exception claimed for <br /> each fixture or group of fixtures under exception category <br /> Yes Table Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ AE1.01 <br /> C405.5.2(1) <br /> Exterior building For building grounds fixtures rated at greater than 100 watts tha <br /> Yes C405.5.1 grounds lighting are complying based on efficacy,indicate rated lamp efficacy(in A2.07 <br /> lumens per watt)in fixture schedule <br /> Exterior lighting Complete required compliance form—proposed wattage for <br /> Yes C405.5.2 power calculations exterior lighting plus base site allowed does not exceed AE1.01 <br /> maximum allowed <br />