• <br /> Floor <br /> ction Plan706 on2 Sheet Detail A2.036/A5.does02have not been comply;revised this wall <br /> to hasallow not beencollapseof revisedthe . See <br /> Se . . <br /> structure on either side, per IBC 2015, Section 706.2. Fire wall resistance per IBC <br /> 2015, Table 706.4. <br /> c. The wall is required to extend from the foundation and extend a minimum of 30 <br /> inches above the roof per Section 706.6, or the construction shall comply with <br /> one of the exceptions. The response states that the roof has been detailed to <br /> comply with Exception 4. However, Section 5/A5.02 does not specify the <br /> required fire-retardant construction. Refer to notes on Detail 6/A5.02, specifying <br /> materials to meet the tested assembly. <br /> Accessibility: <br /> 4. This comment has not been completely addressed. The original comment is <br /> provided below. Documentation was not submitted as stated in the original <br /> comment. The building does not appear to be fully-accessible. The restrooms at <br /> the east end of the building are not accessible. Accessible restrooms must be <br /> located in the same area as non-accessible restrooms; accessible restrooms on the <br /> opposite side of the building do not comply. Refer to Sheet A2.03 at Existing <br /> Women-115; Old sink shall be replaced to allow additional clearance around the <br /> water closet as per ANSI 2009. Please note the existing Mens meets the ANSI 2009 <br /> requirement. <br /> Original comment: The project involves both Level 2 Alterations and an Addition to <br /> the building per IEBC Chapters 8 and 11. Accessibility improvements per IEBC <br /> Section 705.2 should be included in the project. Where the building is made to be <br /> less than fully-accessible per one of the exceptions, documentation substantiating <br /> the limited accessibility improvements should be submitted for review. Where <br /> Exception 1 is used, the documentation should itemize the improvements and <br /> estimated cost of work associated with each item. See IEBC Sections 806.1 and <br /> 1105.1. <br /> 5. This comment has not been completely addressed. The revised ramp design <br /> appears generally compliant. The handrail height and extensions should be <br /> dimensioned. The top outer rail should extend parallel to the ramp run; the <br /> horizontal bend does not comply. See IBC Sections 1014.2 and 1014.6. Sheet <br /> A2.03; Floor plan has been revised to reconfigure the ADA ramp flight. The new <br /> configuration should avoid horizontal bend at end of ramp. <br /> Structural: (Please refer to a separate enclosed documents with Response to Comment) <br /> P P <br /> -End- <br /> PAGE 2 OF 2 <br />