2511 CLEVELAND AVE 2023-06-26
>
Address Records
>
CLEVELAND AVE
>
2511
>
2511 CLEVELAND AVE 2023-06-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/26/2023 2:59:53 PM
Creation date
6/7/2023 6:22:46 AM
Metadata
Fields
Template:
Address Document
Street Name
CLEVELAND AVE
Street Number
2511
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A B C I D E F I G H <br /> COMBINER BOX PANEL SIZE CALCS MAX AC OPERATING CURRENT CALCS FOR HM-1200 <br /> NUMBER OF NUMBER OF NOMINAL OUTPUT COMBINED #OF MICROINVERTERS MAX OUTPUT CURRENT MAX AC OPERATING CURRENT <br /> CIRCUIT# MODULES MICROINVERTERS CURRENT TOTAL 125% TOTAL TOTAL BREAKER SIZE 5 jx5.OA = 25.00A <br /> CIRCUIT 1 12 3 X 5.OA - 15.00A x 1.25 - 18.75A = N/A - <br /> CIRCUIT 2 8 2 X 5.OA - 10.00A x 1.25 - 12.50A = N/A - <br /> BREAKER SIZE CALCS <br /> LOAD CALCS-TOTAL AMPS AVAILABLE <br /> BUS RATING 120% TOTAL MAIN BREAKER MAX BREAKER SIZE MAX AC OPERATING CURRENT 125% TOTAL BREAKER SIZE <br /> 125A X 1.2 - 150 100A - 50A 25.00A x 1.25 x 31.25A = 35A <br /> NOTES: <br /> 1. 200A UTILITY METER&125A LOAD CENTER INSTALLED WITH SURGE PROTECTION.(NEW) <br /> 2. 60A RATED NON-FUSED LOCKABLE AC DISCONNECT.(NEW) (2)8 AWG <br /> 3. 125A RATED COMBINER PANEL.(NEW) (1)8 AWG EGC MAIN SERVICE PANEL(N (__1 OOA <br /> ALL CONDUIT SIZES ARE MINIMUM SIZES MAIN SERVICE <br /> (V ALL WIRE SIZES ARE FOR COPPER WIRE DISCONNECT(N) Iv <br /> 2 M <br /> 3 <br /> 12 ZNSHINE ZXM6-NH120-360M MODULES <br /> co WITH HOYMILES HM-1200 MICRO w <br /> INVERTERS (2)8 AWG <br /> (1)8 AWG EGC <br /> °3 a3 35A LOAD-SIDE 1 <br /> `12� `4J `3� `2J `1� CIRCUIT#1 (Opposite end of the main disconnect <br /> on the busbar-NEC 705.12(B)(3) <br /> • • • (2)12 AWG <br /> (1)8 AWG EGC <br /> 8 ZNSHINE ZXM6-NH120-360M MODULES <br /> WITH HOYMILES HM-1200 MICRO <br /> INVERTERS <br /> `8J `4J `3'� CIRCUIT#2 <br /> (2)12 AWG <br /> (1)8AWG EGC <br /> LO (n <br /> ti ti <br /> DRAWN BY: DRAWING SCALE: <br /> CONFIDENTIAL-THE INFORMATION CONTAINED PJV NOT TO SCALE <br /> IN THIS PACKET AND SUBSEQUENT CUTSHEETS Tyler I d rog o DATE: DESIGN <br /> S <br /> SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER <br /> O L G C N ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 14/02/2023 <br /> SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 <br /> P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN PAGE# <br /> CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 2511 Cleveland Avenue, Everett, WA 98201 <br /> RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV <br /> CONSENT FROM SOLGEN POWER. <br />