SCOPE OF WORK <br />GOVERNING CODES <br />TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE <br />LOCATED AT 1181624TH DR BE, EVERETT, WA 9848, USA. <br />M18 INTERNATIONAL BUILDING CODE <br />THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY <br />201E INTERNATIONAL FIRE CODE <br />GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. <br />2018 INTERNATIONAL RESIDENTIAL CODE <br />THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. <br />M20 NATIONAL ELECTRICAL CODE <br />WASHINGTON ADMINISTRATIVE CODE (WAC) <br />EQUIPMENT SUMMARY <br />AHJ NAME : CITY OF EVERETT <br />24 Q CELLS O.PEAK DUO BLK MLG10� (400W) MODULES <br />WIRING AND CONDUIT NOTES <br />24 ENPHASE IOBPLUS-72.2-US (240V) MICROINVERTERS <br />ALL CONDUIT SIZES AND TYPES SHALL BE LISTED FOR ITS PUFF <br />APPROVAL FOR THE SITE APPLICATIONS <br />GENERAL NOTES <br />ALL PV CABLES AND HOMERUN WIRES BE #1O ING'USE-2, PV WI <br />. THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND <br />PROPRIETARY SOLAR CABLING SPECIFIED BY MFR, OR EQUIVALE <br />OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE <br />SOURCE CIRCUIT COMBINER BOXES AS REQUIRED <br />MODIFICATIONS IN CONSTRUCTION DETAILS. <br />ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR <br />INSTALLATION OF ANY EQUIPMENT AT SITE. <br />LL CONTRACTOR SHAFURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL <br />PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. <br />CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS <br />AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER <br />BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION AND <br />ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE <br />CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL <br />COMPENSATION. <br />DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, FLOORS, <br />ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE <br />CONTRACTOR AT NO ADDITIONAL COST. <br />THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND <br />COMPLETION OF THE WORK WITH APPROVED MATERIALS. <br />NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE <br />ARCHITECT. <br />CONTRACTOR SHALL OBTAIN BUILDING PERMIT. NO WORK TO START UNLESS BUILDING <br />PERMIT IS PROPERLY DISPLAYED. <br />ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE <br />WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, THE DEPARTMENT OF <br />ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. <br />IT 1S ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL <br />PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. <br />THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. <br />ALL EXPOSED PLUMBING, HVAC, ELECTRICAL DUCTWORK, PIPING AND CONDUITS ARE TO <br />BE PAINTED BY GENERAL CONTRACTOR. <br />THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE <br />LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. <br />THE CONTRACTOR $HALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS, <br />ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. <br />CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK <br />ELECTRICAL NOTES <br />• ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. <br />• ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 9D DEGREE C WET <br />ENVIRONMENT. <br />• WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY <br />TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. <br />• WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL <br />COMPLY WITH NEC 110.26. <br />• WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE <br />CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br />• ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br />• MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE <br />SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. <br />• MODULE SUPPORT RAIL SHALL BE BONDED TO THE MODULE <br />GE AND <br />RE, OR <br />NT; ROUTED TO <br />ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE <br />DERATED ACCORDING TO AS PER LATEST NEC CODE. <br />EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90'C RATED, WET AND UV <br />RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE <br />USED TO PROTECT WIRE FROM SHARP EDGE$ <br />PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 <br />INSULATED, SWC RATED, WET AND UV RESISTANT, RATED FOR 1000V PER NEC <br />2017 <br />0.WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER <br />VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE <br />MEANS <br />ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION <br />VOLTAGE DROP LIMITED TO 2% <br />AC CONDUCTORS> AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, <br />PHASE B OR L2- RED, PHASE C OR L3-BLUE, NEUTRAL- WHITE/GRAY <br />VOLTAGE DROP LIMITED TO 2% <br />AC CONDUCTORS> AWG COLOR CODED OR MARKED: PHASE AOR L1- BLACK, <br />PHASE B OR L2- RED, PHASE C OR L3-BLUE, NEUTRAL- WHITE/GRAY <br />SYSTEM RATING PHOTOVOLTAIC SYSTEM FIRE <br />9E&M kWDC CLASSIFICATION LISTING IN <br />ACCORDANCE WITH UL 1703 <br />721M KWAC STANDARD. <br />$HEET INDEX <br />PV1 <br />COVERPAGE <br />PV2 <br />SITE PIM <br />PV3 <br />ROOF PLAN <br />PV4 <br />STRING LAYOUT S BOM <br />PVSFVS <br />ATTACHMENTDETAILS <br />PV7 <br />ELECTRICAL LINE B CALCS, <br />PVS <br />SPECIFICATIONS B NOTES <br />PV&PV1D <br />SIGNAGE <br />PV11 <br />JOB SAFETY PLAN <br />PVU2 I <br />EQUIPMENT SPECIFICATIONS <br />HOUSE PHOTO <br />a <br />Thornton A. �!R <br />Sullivan Park 110,haSE <br />© p Ih SI SE Eastman <br />t <br />/T <br />Amazon Go <br />ONi kta Terms of Use Repoft a map enoi <br />VICINITY MAP a ',,I I" <br />lumio * <br />SMART ENERGY TODAY <br />ISM DIGIT DR LEHI, UT <br />B 3. USA <br />DATEv14nD2z <br />SHEET NAME <br />COVER PAGE <br />$HEM SIZE <br />ANSI B <br />I X 17" <br />SHEET NUMBER <br />PV-1 <br />