SCOPE OF WORK
<br />GOVERNING CODES
<br />TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE
<br />LOCATED AT 1181624TH DR BE, EVERETT, WA 9848, USA.
<br />M18 INTERNATIONAL BUILDING CODE
<br />THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY
<br />201E INTERNATIONAL FIRE CODE
<br />GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT.
<br />2018 INTERNATIONAL RESIDENTIAL CODE
<br />THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES.
<br />M20 NATIONAL ELECTRICAL CODE
<br />WASHINGTON ADMINISTRATIVE CODE (WAC)
<br />EQUIPMENT SUMMARY
<br />AHJ NAME : CITY OF EVERETT
<br />24 Q CELLS O.PEAK DUO BLK MLG10� (400W) MODULES
<br />WIRING AND CONDUIT NOTES
<br />24 ENPHASE IOBPLUS-72.2-US (240V) MICROINVERTERS
<br />ALL CONDUIT SIZES AND TYPES SHALL BE LISTED FOR ITS PUFF
<br />APPROVAL FOR THE SITE APPLICATIONS
<br />GENERAL NOTES
<br />ALL PV CABLES AND HOMERUN WIRES BE #1O ING'USE-2, PV WI
<br />. THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND
<br />PROPRIETARY SOLAR CABLING SPECIFIED BY MFR, OR EQUIVALE
<br />OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE
<br />SOURCE CIRCUIT COMBINER BOXES AS REQUIRED
<br />MODIFICATIONS IN CONSTRUCTION DETAILS.
<br />ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR
<br />INSTALLATION OF ANY EQUIPMENT AT SITE.
<br />LL CONTRACTOR SHAFURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL
<br />PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION.
<br />CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS
<br />AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER
<br />BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION AND
<br />ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE
<br />CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL
<br />COMPENSATION.
<br />DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, FLOORS,
<br />ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE
<br />CONTRACTOR AT NO ADDITIONAL COST.
<br />THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND
<br />COMPLETION OF THE WORK WITH APPROVED MATERIALS.
<br />NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE
<br />ARCHITECT.
<br />CONTRACTOR SHALL OBTAIN BUILDING PERMIT. NO WORK TO START UNLESS BUILDING
<br />PERMIT IS PROPERLY DISPLAYED.
<br />ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE
<br />WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, THE DEPARTMENT OF
<br />ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES.
<br />IT 1S ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL
<br />PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING.
<br />THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH.
<br />ALL EXPOSED PLUMBING, HVAC, ELECTRICAL DUCTWORK, PIPING AND CONDUITS ARE TO
<br />BE PAINTED BY GENERAL CONTRACTOR.
<br />THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE
<br />LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE.
<br />THE CONTRACTOR $HALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS,
<br />ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES.
<br />CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK
<br />ELECTRICAL NOTES
<br />• ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION.
<br />• ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 9D DEGREE C WET
<br />ENVIRONMENT.
<br />• WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY
<br />TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.
<br />• WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL
<br />COMPLY WITH NEC 110.26.
<br />• WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE
<br />CONTRACTOR SHALL SIZE THEM ACCORDINGLY.
<br />• ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE.
<br />• MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE
<br />SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION.
<br />• MODULE SUPPORT RAIL SHALL BE BONDED TO THE MODULE
<br />GE AND
<br />RE, OR
<br />NT; ROUTED TO
<br />ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE
<br />DERATED ACCORDING TO AS PER LATEST NEC CODE.
<br />EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90'C RATED, WET AND UV
<br />RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE
<br />USED TO PROTECT WIRE FROM SHARP EDGE$
<br />PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2
<br />INSULATED, SWC RATED, WET AND UV RESISTANT, RATED FOR 1000V PER NEC
<br />2017
<br />0.WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER
<br />VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE
<br />MEANS
<br />ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION
<br />VOLTAGE DROP LIMITED TO 2%
<br />AC CONDUCTORS> AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK,
<br />PHASE B OR L2- RED, PHASE C OR L3-BLUE, NEUTRAL- WHITE/GRAY
<br />VOLTAGE DROP LIMITED TO 2%
<br />AC CONDUCTORS> AWG COLOR CODED OR MARKED: PHASE AOR L1- BLACK,
<br />PHASE B OR L2- RED, PHASE C OR L3-BLUE, NEUTRAL- WHITE/GRAY
<br />SYSTEM RATING PHOTOVOLTAIC SYSTEM FIRE
<br />9E&M kWDC CLASSIFICATION LISTING IN
<br />ACCORDANCE WITH UL 1703
<br />721M KWAC STANDARD.
<br />$HEET INDEX
<br />PV1
<br />COVERPAGE
<br />PV2
<br />SITE PIM
<br />PV3
<br />ROOF PLAN
<br />PV4
<br />STRING LAYOUT S BOM
<br />PVSFVS
<br />ATTACHMENTDETAILS
<br />PV7
<br />ELECTRICAL LINE B CALCS,
<br />PVS
<br />SPECIFICATIONS B NOTES
<br />PV&PV1D
<br />SIGNAGE
<br />PV11
<br />JOB SAFETY PLAN
<br />PVU2 I
<br />EQUIPMENT SPECIFICATIONS
<br />HOUSE PHOTO
<br />a
<br />Thornton A. �!R
<br />Sullivan Park 110,haSE
<br />© p Ih SI SE Eastman
<br />t
<br />/T
<br />Amazon Go
<br />ONi kta Terms of Use Repoft a map enoi
<br />VICINITY MAP a ',,I I"
<br />lumio *
<br />SMART ENERGY TODAY
<br />ISM DIGIT DR LEHI, UT
<br />B 3. USA
<br />DATEv14nD2z
<br />SHEET NAME
<br />COVER PAGE
<br />$HEM SIZE
<br />ANSI B
<br />I X 17"
<br />SHEET NUMBER
<br />PV-1
<br />
|