OONTRAOTOR INFORMATON <br />1. EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER <br />NATIpIWIDE SOIAR <br />2W FIN ST. <br />MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND <br />csNB# EI AELLEEN99JM3 <br />METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING GROUNDING <br />m,,,"�EPi°° 67„' <br />ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, <br />IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL <br />Natbmvide <br />slum <br />GROUNDING ELECTRODE. <br />2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL <br />w;mNmDesaua� <br />ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED OR <br />MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL <br />61 °.mb,a.,„,.tbAmN <br />BE UV RESISTANT IF EXPOSED TO SUNLIGHT. <br />VERSION <br />3. DC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, "CAUTION DC <br />CIRCUIT" OR EQUIV. EVERY 5 FT. <br />4. EXPOSED NON -CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT <br />SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.138(A). <br />5. CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO <br />CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER <br />VOLTAGE OPERATIONAL RANGE. <br />6. OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER. <br />PROJECT NmaE <br />7. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND <br />< <br />ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. <br />p <br />p 0 <br />k <br />8. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL <br />MEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR ROOF -MOUNTED <br />SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE <br />ROOF SURFACE. NEC 110.2 - 110.4 / 300.4 <br />LLiU <br />N ao n w <br />H N v w <br />O V) co In <br />W 2 ¢ p = <br />m ?y IN� L p <br />of <br />¢ I�HN <br />w a : <br />w <br />w <br />w <br />O <br />U <br />w <br />LL <br />SHEET NAME <br />ADDITIONAL NOTES <br />ANSI B <br />11" X 17" <br />SHEET NUMBER <br />PV-8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.