My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-51 2023-06-15
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-51
>
3003 W CASINO RD BLDG 40-51 2023-06-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2023 9:04:59 AM
Creation date
6/15/2023 8:34:36 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-51
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXHAUST FAN <br />15> <br />NOT IN AUTO <br />HOA WITH LOS <br />HEAT RECOVERY WHEEL <br />(HRW-XX) <br />11> <br />I I I I <br />PUSHBUTTON PUSHBUTTON PUSHBUTTON PUSHBUTTON <br />HS HS HS HS <br />0 XXO 0 XX03 0 XX04 0 XX05 <br />EMERGENCY TRUN <br />XXO TRUN <br />XX04 <br />SHUTDOWN ,,VENTILATION RUN OFF <br />SYSTEM 0 0 <br />EMERGENCY <br />SHUTOFF OPERATIONAL OPERATIONAL OPERATIONAL BOOTH <br />MODE MODE MODE VENTILATION <br />A B C SYSTEM OFF <br />WING PREPARATION PAINTING CURE <br />GENERAL NOTES: <br />A. REFER TO DRAWINGS M310a FOR <br />SEQUENCE OF OPERATION ASSOCIATED <br />WITH THIS CONTROL DIAGRAM. <br />B. ALL TCV'S SHALL BE SUPPLIED WITH <br />POSITIVE POSITIONERS. <br />C. WHERE THE TERM "EXISTING FACILITY <br />ENERGY MANAGEMENT SYSTEM" IS USED, <br />REFERENCE IS BEING MADE TO THE <br />HONEYWELL DELTA 5200 SYSTEM LOCATED <br />IN THE 40-11 BUILDING. <br />D. SEE DRAWING M2b FOR CONTROL SYSTEM <br />SYMBOLS, ABBREVIATIONS, AND NOTES. <br />E. CONTROL WIRING SHALL BE INSTALLED PER <br />SPECIFICATION SECTION 15975. <br />F. COMPRESSED AIR SHALL BE OBTAINED AND <br />INSTALLED PER SPECIFICATION SECTION <br />15975. <br />SPECIFIC NOTES: <br />ED HUMIDITY HIGH LIMIT OVERRIDE <br />TEMPERATURE HIGH LIMIT OVERRIDE <br />3� SETPOINT FOR THIS TEMPERATURE <br />TRANSMITTER IS 39 °F (DURING CURE <br />MODE ONLY). <br />® FILTER CHANGE OUT SETPOINT IS <br />0.75" W.G. <br />THIS EXHAUST FAN IS TYPICAL FOR <br />EF-39 & EF-40. <br />© THIS SUPPLY FAN IS TYPICAL FOR SF-13 <br />THROUGH SF-16. EACH HEAT <br />RECOVERY UNIT ENCLOSURE INCLUDES <br />TWO SUPPLY FANS. BOTH FANS SHALL <br />BE CONTROLLED BY ONE VFD. <br />SUPPLY FAN <br />' <br />(PHC-XX) <br />` ul"HEAT <br />EHRW-4. <br />/ <br />(SF-XX) <br />TYPICAL F OREHRW-3, AND <br />O.A. INTAKE <br />/ <br />© <br />10 <br />DUCT HUMIDIFIER (HU-XX) <br />g <br />THESE HEATING COILS ARE TYPICAL <br />/ <br />HC-3 AND HC-4. <br />/ <br />FACE & BYPASS <br />f <br />12'-0" MINIMUM <br />� <br />THIS DUCT HUMIDIFIER IS TYPICAL <br />/ <br />z <br />t <br />DAMPERS N.C. <br />( <br />\ <br />6'-0" MINIMUM <br />SUPPLY <br />HU-3 AND HU-4. <br />j <br />o <br />f <br />TO FACE) <br />/ <br />10'-0" MAXIMUM <br />H TO BOOTH <br />10 <br />THIS PREHEAT COIL IS TYPICAL FOR <br />PHC-3 & PHC-4. <br />j <br />H L <br />M <br />M <br />ffj> <br />ONLY ONE SPACE TEMPERATURE AND <br />3 <br />MT <br />1 <br />TT <br />2 <br />AS <br />F <br />HUMIDITY TRANSMITTER IS REQUIRED <br />HEATING COIL <br />�,� <br />,,,,�� <br />PER VERTICAL PAINT BOOTH. <br />90 PSIG <br />90 PSIG <br />SUPPLY <br />LOCATE IN VERTICAL PAINT BOOTH <br />COMPRESSED AIR SUPPLY i _QO H R U - 3 & H R U - 4 SPT=70 °F MT SPT=40% RH <br />TO PAINT BOOTH FOR HEATING MODE CURE MODE <br />SPRAYING APPLICATIONS SPT=120OF 3 XXO1 7 g <br />CURE MODE <br />COMPRESSED AIR SUPPLY <br />TO PAINT BOOTH FOR <br />SPRAYING APPLICATIONS <br />\/FRTIr.Al <br />RnnTH rnNTRnI nIArRANA <br />REFERENCE POINT REFERENCE POINT <br />INSIDE PAINT BOOTH OUTSIDE PAINT BOOTH <br />PAINT BOOTH/BUILDING AMBIENT <br />DIFFERENTIAL PRESSURE INDICATION <br />SPT=0.05" W.G. <br />PROFESSIONAL STAMP & SIGNATURE ` ENGINEERS <br />APPLIES TO WORK WITHIN THE CLOUDED Seattle H Spokane H Baltimore <br />REVISION AREAS ONLY AS INDICATED <br />12 SEE SHEET M6 FOR VALVE SIZE. <br />13 LIQUID SENSOR ALARM PANEL. SEE <br />SHEET 1 E61 FOR LOCATION OF PANEL. <br />14 WHEN A LEAK IS DETECTED BY THE LEAK <br />DETECTION MONITORING SYSTEM SPECIFIED <br />IN SECTION 15421 THROUGH MISCELLAN- <br />EOUS RELAY ALARM XXA-OXX01, THIS <br />ALARM CONDITION SHALL BE INDICATED AT <br />THE EXISTING FACILITY ENERGY MANAGEMENT <br />SYSTEM. CONTROLS CONTRACTOR SHALL <br />COORDINATE WITH THE LEAK DETECTION <br />MONITORING SYSTEM MANUFACTURER FOR <br />INTERFACE REQUIREMENTS. <br />SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY Uzis NAWN A LD7-22 SUBTITLE VERTICAL PAINT BOOTH CURRENT W782 REVISION SYMBOL O ORIC 06.27.2022 <br />THIS DESIGN AND/OR CHECKED DATE <br />C� O <br />ORIG 767 VERTICAL PAINT BOOTH VENTILATION -PHASE 2W5523782 FSi KMC 06.27.2022 M. Cyq SPECIFICATION IS APPROVED KMC 01-07-22 CONTROL DIAGRAM SHEET <br />BOE//VO ® y ENGINEER TITLE 767 VERTICAL PAINT BOOTH VENTILATION - PHASE 2 M 3 1 0� 1 <br />APPROVED BY DEPT. DATE ZJS 01-07-22 <br />CHECKED <br />N a s e �2 KMC D, -D7-22 IsT F rG\APPROVED <br />BUILDING 40-051 JOB NO. COMPND. <br />APPROVED <br />fSS/ONAL E <br />oez7 <br />APPROVED MECHANICAL MASTER COL. EVERETT, WA DWG NO. 40-051-M310-1 <br />smmxsn <br />
The URL can be used to link to this page
Your browser does not support the video tag.