Gas Line <br />THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER WHEN INSTALLED WITHIN THE <br />COMMONWEALTH OF MASSACHUSETTS. <br />OTHER MASSACHUSETTS CODE REQUIREMENTS: <br />• Flexible connector must rot be longer Men 36 inches. <br />• Shutoff valve must be a'T" handle gas cock. <br />• Only direct vent sealed combustion products are approved for bedrooms or bathrooms. <br />• Fireplace dampers must be removed or welded in Mai open position prior M the installation of a fireplace insert or gas ag. <br />The gas line must be Installed in accordance with all local codes if any; if not, follow ANSI 223.1 and <br />the requirements listed below. <br />A manual shutoff valve is required within 3' of Me heater. It should be placed upstream of the Flex line <br />(if used) and may be installed behind the access door inside the heater. <br />The heater and gas control valve must be disconnected from the gas supply piping during any <br />pressure testing of Mat system at test pressures in excess of 112 psig. For pressures under 1/2 psig, <br />isolate the gas supply piping by closing Me manual shutoff valve. <br />Leak lest all gas line joints and Me gas control valve prior to and after starting the heater. <br />This heater is designed either for natural gas or for propane (but not for both). Check the sticker on <br />the top of the gas control valve to make sure the conect fuel is used (see illustration on page 4). <br />Installation must be performed by a qualified installer, service agency, or the gas supplier In <br />Massachusetts a licensed plumber/gas-fitter). <br />Gas Inlet Pressure <br />Gas Pressure <br />Max. Input Pressure <br />Min. Input pressure <br />Max. Menton Pressure <br />Min. Manifold Pressure <br />Natural Gas <br />- WC. (V4 KFA) <br />5.5" W.C. (1.3T KFA) <br />3.5" W.C. (o.eT kPA) <br />1 8" WC. (0A0 kPA) <br />Propane <br />13" W.C. (3.23 kPA) <br />11" W.O. (2.T4 WA) <br />1l" W.C. (2.74 kPA) <br />2 9" WC. (0.72 kPA) <br />If Me pressure Is not sufficient, make sure the piping used is large enough, the supply regulator is <br />adequately adjusted, and Me total gas load for the residence does not exceed the amount supplied. <br />The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank) <br />should supply gas at the suggested input pressure listed above. Contact the local gas supplier if the <br />regulator is at an improper pressure. <br />Dlreotions for Connecting a Gas Pressure Test Gauge Out 1411 <br />The gas control valve loosen to Me night) has tec test ports Mr tasting input (lire z <br />pressure) and oalput (manifold) pressure. Loosen the brass some on either rest part m <br />and pace a 5115' i.d. rubber or plasOctube overthe tapered test Pon. Connect the <br />Mbe to the test gauge. <br />WARNING: Tbeb mscrewmustbedgMenedaflertestingtapmventgasleakege. In Port <br />0 Travis Industries 4/25Y1023 -1521 430 EG GSR2 <br />