Laserfiche WebLink
Horizontal Termination <br />Duravenl manufactures a vent kit for horizontal that allows for terminating horizontally when installed in a <br />masonry fireplace (not for use with ZC fireplaces). The DuaVent kit (46DVA-HCL33 and 46DVA HCL34) <br />is approved for use with Travis Industries gas inserts. <br />These kits can be purchased from your Travis Industries dealer. <br />ADDlicatim <br />DuraV•nl Part# <br />For inserts that use 3"exhaust and 3"intake <br />i 460VA-HCL33 <br />For inserts that use 4" exhaust and 3" <br />intake <br />I 46UVA-HCL34 <br />Refer to Me kit manufacturer's instructions for details and requirements for installation. In addition to the <br />manufadurefs requirements, the following requirements must be met: <br />• The termination center MUST be <br />a minimum of V from the base of <br />insert. <br />• The termination center MUST <br />NOT be more than 8' from the <br />base of the insert. <br />• The radius of any bends in the <br />Flexible venting MUST NOT be <br />less than a 4" radius <br />• All portions of Me venting MUST <br />have at least a 114" rise per 12" of <br />horizontal run <br />T <br />in. 5' <br />ax. 8' <br />0 Travis Industries 4/26Y1023 -1521 430 EG GSR2 <br />