My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Valdez Construction 6/12/2023
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
Valdez Construction 6/12/2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2025 12:10:36 PM
Creation date
6/16/2023 10:20:25 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Valdez Construction
Approval Date
6/12/2023
Council Approval Date
5/10/2023
Department
Transportation Services
Department Project Manager
Vincent Bruscas
Subject / Project Title
Eclipse Mill Park Inductive Charging Infrastructure
Tracking Number
0003790
Total Compensation
$923,272.10
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
Document Relationships
Valdez Construction 10/10/2024 Change Order 2
(Contract)
Path:
\Records\City Clerk\Contracts\10 Years Then Transfer to State Archivist\2024
Valdez Construction 5/1/2024 Amendment 1
(Contract)
Path:
\Records\City Clerk\Contracts\10 Years Then Transfer to State Archivist\2024
Valdez Construction 5/5/2025 Change Order 3
(Contract)
Path:
\Records\City Clerk\Contracts\10 Years Then Transfer to State Archivist\2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
458
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Everett 26 00 10 - 9 <br /> Inductive Charging Infrastructure for Everett Transit <br /> g. Extension Ring: A ring intended to extend the sides of an outlet box or <br /> device box to increase the box depth, volume, or both. <br /> h. Floor Box: A box mounted in the floor intended for use with a floor box <br /> cover and other components to complete the floor box enclosure. <br /> i. Floor-Mounted Enclosure: A floor box and floor box cover assembly with <br /> means to mount in the floor that is sealed against the entrance of scrub <br /> water at the floor level. <br /> j. Floor Nozzle: An enclosure used on a wiring system, intended primarily as <br /> a housing for a receptacle, provided with a means, such as a collar, for <br /> surface-mounting on a floor, which may or may not include a stem to <br /> support it above the floor level, and is sealed against the entrance of scrub <br /> water at the floor level. <br /> k. Junction Box: A box with a blank cover that joins different runs of raceway <br /> or cable and provides space for connection and branching of the enclosed <br /> conductors. <br /> I. Outlet Box: A box that provides access to a wiring system having pryout <br /> openings, knockouts, threaded entries, or hubs in either the sides or the <br /> back, or both, for the entrance of conduit, conduit or cable fittings, or <br /> cables, with provisions for mounting an outlet box cover, but without <br /> provisions for mounting a wiring device directly to the box. <br /> m. Pedestal Floor Box Cover: A floor box cover that, when installed as <br /> intended, provides a means for typically vertical or near-vertical mounting <br /> of receptacle outlets above the floor's finished surface. <br /> n. Pull Box: A box with a blank cover that joins different runs of raceway and <br /> provides access for pulling or replacing the enclosed cables or conductors. <br /> o. Raised-Floor Box: A floor box intended for use in raised floors. <br /> p. Recessed Access Floor Box: A floor box with provisions for mounting <br /> wiring devices below the floor surface. <br /> q. Recessed Access Floor Box Cover: A floor box cover with provisions for <br /> passage of cords to recessed wiring devices mounted within a recessed <br /> floor box. <br /> r. Ring: A sleeve, which is not necessarily round, used for positioning a <br /> recessed wiring device flush with the plaster, concrete, drywall, or other <br /> wall surface. <br /> s. Ring Cover: A box cover, with raised center portion to accommodate a <br /> specific wall or ceiling thickness, for mounting wiring devices or luminaires <br /> flush with the surface. <br /> t. Termination Box: An enclosure designed for installation of termination base <br /> assemblies consisting of bus bars, terminal strips, or terminal blocks with <br /> provision for wire connectors to accommodate incoming or outgoing <br /> conductors, or both. <br /> 10. Emergency Systems: Those systems legally required and classed as emergency <br /> by municipal, state, federal, or other codes, or by any governmental agency <br /> having jurisdiction that are designed to ensure continuity of lighting, electrical <br /> power, or both, to designated areas and equipment in the event of failure of the <br /> normal supply for safety to human life. <br /> 11. Essential Electrical Systems: (healthcare facilities) Those systems designed to <br /> ensure continuity of electrical power to designated areas and functions of a <br /> healthcare facility during disruption of normal power sources, and also to <br /> minimize disruption within the internal wiring system. <br /> 12. Fault Limited: Providing or being served by a source of electrical power that is <br /> limited to not more than 100 W when tested in accordance with UL 62368-1. <br /> 26 00 10 - 9 SUPPLEMENTAL REQUIREMENTS FOR ELECTRICAL <br />
The URL can be used to link to this page
Your browser does not support the video tag.