Valdez Construction 6/12/2023
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
Valdez Construction 6/12/2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2025 12:10:36 PM
Creation date
6/16/2023 10:20:25 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Valdez Construction
Approval Date
6/12/2023
Council Approval Date
5/10/2023
Department
Transportation Services
Department Project Manager
Vincent Bruscas
Subject / Project Title
Eclipse Mill Park Inductive Charging Infrastructure
Tracking Number
0003790
Total Compensation
$923,272.10
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
Document Relationships
Valdez Construction 10/10/2024 Change Order 2
(Contract)
Path:
\Records\City Clerk\Contracts\10 Years Then Transfer to State Archivist\2024
Valdez Construction 5/1/2024 Amendment 1
(Contract)
Path:
\Records\City Clerk\Contracts\10 Years Then Transfer to State Archivist\2024
Valdez Construction 5/5/2025 Change Order 3
(Contract)
Path:
\Records\City Clerk\Contracts\10 Years Then Transfer to State Archivist\2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
458
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Everett 26 22 13 -4 <br /> Inductive Charging Infrastructure for Everett Transit <br /> B. Factory Tests and Inspections: Test and inspect assembled system, by, or under <br /> supervision of, qualified electrical testing laboratory recognized by authorities having <br /> jurisdiction, in accordance with IEEE C57.12.01 and IEEE C57.12.91 before delivering <br /> to site. Affix label with name and date of manufacturer's certification of system <br /> compliance on control units. <br /> 1. Resistance measurements of windings at rated voltage connections and at tap <br /> connections. <br /> 2. Ratio tests at rated voltage connections and at tap connections. <br /> 3. Phase relation and polarity tests at rated voltage connections. <br /> 4. No load losses, and excitation current and rated voltage at rated voltage <br /> connections. <br /> 5. Impedance and load losses at rated current and rated frequency at rated voltage <br /> connections. <br /> 6. Applied and induced tensile tests. <br /> 7. Regulation and efficiency at rated load and voltage. <br /> 8. Insulation-Resistance Tests: <br /> a. Line-side to ground. <br /> b. Load-side to ground. <br /> c. Line-side to load-side. <br /> 9. Temperature tests. <br /> 10. Factory Sound-Level Tests: Conduct prototype sound-level tests on production- <br /> line products. <br /> C. Nonconforming Work: <br /> 1. System equipment that does not pass tests and inspections will be considered <br /> defective. <br /> D. Prepare test and inspection reports. <br /> PART 3 - EXECUTION <br /> 3.1 EXAMINATION <br /> A. Examine conditions for compliance with enclosure- and ambient-temperature <br /> requirements for transformers. <br /> B. Verify that field measurements are as needed to maintain working clearances required <br /> by NFPA 70 and manufacturer's published instructions. <br /> C. Examine walls, floors, roofs, and concrete bases for suitable mounting conditions <br /> where transformers will be installed. <br /> D. Verify that ground connections are in place and requirements in Section 260526 <br /> "Grounding and Bonding for Electrical Systems" have been met. Maximum ground <br /> resistance must be 5 0 at location of transformer. <br /> E. Environment: Isolation transformer enclosure must be rated NEMA 3R. <br /> 26 22 13 -4 LOW-VOLTAGE DISTRIBUTION TRANSFORMERS <br />