My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Valdez Construction 6/12/2023
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
Valdez Construction 6/12/2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2025 12:10:36 PM
Creation date
6/16/2023 10:20:25 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Valdez Construction
Approval Date
6/12/2023
Council Approval Date
5/10/2023
Department
Transportation Services
Department Project Manager
Vincent Bruscas
Subject / Project Title
Eclipse Mill Park Inductive Charging Infrastructure
Tracking Number
0003790
Total Compensation
$923,272.10
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
Document Relationships
Valdez Construction 10/10/2024 Change Order 2
(Contract)
Path:
\Records\City Clerk\Contracts\10 Years Then Transfer to State Archivist\2024
Valdez Construction 5/1/2024 Amendment 1
(Contract)
Path:
\Records\City Clerk\Contracts\10 Years Then Transfer to State Archivist\2024
Valdez Construction 5/5/2025 Change Order 3
(Contract)
Path:
\Records\City Clerk\Contracts\10 Years Then Transfer to State Archivist\2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
458
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Everett 26 24 16 -4 <br /> Inductive Charging Infrastructure for Everett Transit <br /> 1. Peak Surge Current Rating: Minimum single-pulse surge current withstand rating <br /> per phase may not be less than 100 kA. Peak surge current rating must be <br /> arithmetic sum of ratings of individual MOVs in given mode. <br /> 2. Protection modes and UL 1449 VPR for grounded wye circuits with 480Y/277 V <br /> 3-phase, four-wire circuits may not exceed the following: <br /> a. Line to Neutral: 1200 V for 480Y/277 V <br /> b. Line to Ground: 1200 V for 480Y7 V <br /> c. Neutral to Ground: 1200 V for 480Y/277 V <br /> d. Line to Line: 2000 V for 480Y/277 V <br /> 3. Protection modes and UL 1449 VPR for 240/120 V, single-phase, three-wire <br /> circuits may not exceed the following: <br /> a. Line to Neutral: 700 V. <br /> b. Line to Ground: 700 V. <br /> c. Neutral to Ground: 700 V. <br /> d. Line to Line: 1200 V. <br /> 4. SCCR: Exceed 200 kA. <br /> 5. (nominal Rating: 20 kA. <br /> F. Buses: <br /> 1. Copper phase and neutral buses; 200 percent capacity neutral bus and lugs. <br /> 2. Copper equipment and isolated ground buses. <br /> 2.2 DISCONNECTING AND OVERCURRENT PROTECTIVE DEVICES <br /> A. MCCB: Comply with UL 489, with interrupting capacity to meet available fault currents <br /> (fully rated). <br /> 1. Thermal-Magnetic Circuit Breakers: <br /> a. Inverse time-current element for low-level overloads. <br /> b. Instantaneous magnetic trip element for short circuits. <br /> c. Adjustable magnetic trip setting for circuit-breaker frame sizes 250 A and <br /> larger. <br /> 2. Adjustable Instantaneous-Trip Circuit Breakers: Magnetic trip element with front- <br /> mounted, field-adjustable trip setting. <br /> 3. Electronic Trip Circuit Breakers: <br /> a. RMS sensing. <br /> b. Field-replaceable rating plug or electronic trip. <br /> c. Digital display of settings, trip targets, and indicated metering displays. <br /> d. Multi-button keypad to access programmable functions and monitored <br /> data. <br /> e. Ten-event, trip-history log. Each trip event must be recorded with type, <br /> phase, and magnitude of fault that caused trip. <br /> f. Integral test jack for connection to portable test set or laptop computer. <br /> g. Field-Adjustable Settings: <br /> 26 24 16 -4 PANELBOARDS <br />
The URL can be used to link to this page
Your browser does not support the video tag.