My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2802 16TH ST 2023-06-27
>
Address Records
>
16TH ST
>
2802
>
2802 16TH ST 2023-06-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/27/2023 9:50:48 AM
Creation date
6/22/2023 6:14:11 AM
Metadata
Fields
Template:
Address Document
Street Name
16TH ST
Street Number
2802
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
! WARNING <br /> LABEL 1 WARNING: PHOTOVOLTAIC AT ATDIRECT-CURRENT EXPOSED RACEWAYS,CABLE TRAYS,COVERS AND <br /> FOR PV DISCONNECTING MEANS WHERE THE LINE AND ENCLOSURES OF JUNCTION BOXES,AND OTHER WIRING METHODS;SPACED <br /> ELECTRIC SHOCK HAZARD LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POWER SOURCE AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES,WALLS, <br /> POSITION. PARTITIONS,CEILINGS,OR FLOORS. <br /> TERMINALS ON BOTH LINE AND [NEC690.13(B)] [NEC 690.31(6)(3&4)] <br /> LOAD SIDES MAY BE ENERGIZED IN <br /> THE OPEN POSITION SOLAR PV SYSTEM EQUIPPED LABEL7 S L A R <br /> WITH RAPID SHUTDOWN FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING <br /> THE SIGN TO BE Revolution Ener Systems Inc. <br /> SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE Energy Y <br /> WARNING LABEL 2 DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND <br /> PLACED ADJACENTTO THE BACK-FED BREAKER FROM TURN RAPID SHUTDOWN SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN 9981 West 190th St <br /> ! SWICH TO THE"OFFPVP"Nes SWITCHES IF NOT AT THE SAME LOCATION. <br /> THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE [NEC 690.56(C)(1)(A)] Unit K Mokena IL 60448 <br /> THIS EQUIPMENT IS FED BY MULTIPLE CONNECTION TO BUSBAR. POSITION TO SHUT DOWN T: 708-995-1643 <br /> [NEC 705.12(13)(2)(3)(b)] PV SYSTEM AND REDUCE <br /> SOURCES. TOTAL RATING OF ALL SHOCK HAZARD IN ARRAY LEI <br /> OVERCURRENT DEVICES, EXCLUDING <br /> MAIN SUPPLY OVERCURRENT <br /> DEVICE, SHALL NOT EXCEED SOLAR . ..ED <br /> LABEL8 <br /> FOR PV SYSTEMS THAT ONLY SHUT DOWN CONDUCTORS <br /> AMPACITY OF BUSBAR. - LEAVING THE ARRAY: SITE INFORMATION <br /> SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY JOHN LUKAS CHUBINSKY <br /> TURN RAPID SHUTDOWN FROM SERVICE DISCONNECTING MEANS TO WHICH THE <br /> © PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE 2802 16TH STREET <br /> i LABEL 3 SWITCH TO THE"OFF' _. I LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN <br /> WARNING <br /> PLACED ADJACENTTO THE BACK-FED BREAKER POSITION TO SHUT DOWN Iā SWITCHES IF NOT AT THE SAME LOCATION. EVERETT,WA 98201 <br /> FROM THE INVERTER IF TIE IN CONSISTS OF LOAD CONDUCTORS OUTSIDE [NEC 690.56(C)(1)(b)] <br /> INVERTER OUTPUT CONNECTION AC System Size:3.90 kW AC/3.90 kVA <br /> SIDE CONNECTION To BUSBAR. THE ARRAY.CONDUCTORS <br /> [NEC 705.12(13)(2)(3)(c)] WITHIN THE ARRAY REMAIN DC System Size:5.40 kW DC <br /> DO NOT RECOLCATE ENERGIZED IN SUNLIGHT <br /> THIS OVERCURRENT Lat,47.9960114 <br /> DEVICE Long,-122.1931020 <br /> RAPID <br /> . , , ⢠LABEL 9 (12)CANADIAN SOALR CS3W-450MS(450W) <br /> SIGN LOCATED AT RAPID SHUT DOWN PV Modules <br /> SWITCH FOR DISCONNECT SWITCH[NEC 690.56(C)(3)]. <br /> (12) ENPHASE IQ8M-72-2-US(240V) <br /> Inverter(s) <br /> i WARNING EQUIPMENT CONTAINING OVERCURRENT SOLAR PV SYSTEM <br /> DEVICES IN CIRCUITS SUPPLYING POWER TO A <br /> DUAL POWER SUPPLY BUSBAR OR CONDUCTOR SUPPLIED FROM <br /> MULTIPLE SOURCES SHALL BE MARKED TO MAIN SERVICE PANEL <br /> SOURCES: UTILITY GRID AND PV INDICATE THE PRESENCE OF ALL SOURCES L SNOHOMISH COUNTY PUD <br /> SOLAR ELECTRIC SYSTEM [NEC 705.12(6)(3)] <br /> LABELING DIAGRAM: <br /> Ol O <br /> EXISTING SUB PANEL PV COMBINER INVERTER(S) <br /> (IF WHERE POINT OF SUBPANEL- <br /> LABELSO O4 INTERCONNECTION IF USED TO COMBINE <br /> PHOTOVOLTAIC AC DISCONNECT AT POINT OF INTERCONNECTION,MARKED AT IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS <br /> AC DISCONNECTING MEANS. <br /> RATEDOUTPUT CURRENT: 16.25 A [NEC 690.54,NEC 690.13(B)] ā O O <br /> O O O <br /> NOMINALOPERATING AC VOLTAGE: 240 V O <br /> O O 00 3 <br /> O JUNCTION BOX <br /> OR COMBINER BOX <br /> LABELING NOTES: oc <br /> 1.LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT O O <br /> REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. <br /> 2.LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE,OSHA STANDARD 19010.145,ANSI (ONLY IF PV (ONLY IF PV ā O O <br /> Z535. INTERCONNECTION INTERCONNECTION o <br /> 3.MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. CONSISTS OF LOAD CONSISTS OF LOAD O O <br /> 4.LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED[NEC 110.21(B)(3)] SIDE BREAKER) SIDE BREAKER) DRAWN BY:JEROME JAPAL <br /> 5.LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8",WHITE ON RED BACKGROUND;REFLECTIVE,AND INTEGRATED DC DISCONNECT <br /> PERMANENTLY AFFIXED[IFC 605.11.1.11 DATE: <br /> *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY.NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED.LABEL LOCATIONS 1/3/2023 <br /> PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE. <br /> LABELS - PV07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.