My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2802 16TH ST 2023-06-27
>
Address Records
>
16TH ST
>
2802
>
2802 16TH ST 2023-06-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/27/2023 9:50:48 AM
Creation date
6/22/2023 6:14:11 AM
Metadata
Fields
Template:
Address Document
Street Name
16TH ST
Street Number
2802
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENPHASE IQ8 Series Microinverters <br /> INPUT DATA r r r: <br /> Commonly used module pairingsz W 235-350 235-440 260-460 295-500 320-540- 295-500, <br /> Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell <br /> MPPT voltage range V 27-37 29-45 33-45 36-45 38-45 38-45 <br /> Operating range V 25-48 25-58 <br /> Min/max start voltage V 30/48 30/58 <br /> Max input DC voltage V 50 60 <br /> Max DC current'[module Isc] A 15 <br /> Overvoltage class DC port II <br /> 0 DC port backfeed current mA 0 <br /> PV array configuration 1x1 Ungrounded array;No additional DC side protection required:AC side protection requires max 20A per branch circuit <br /> OUTPUT DATA LAC) IQ8-60-2-US IQBPLUS-72-2-US 108M-72-2-US IQBA-72-2-US IQ8 11-2�0-72-2-US IQ8 H-208-72-2-US, <br /> Peak output power VA 245 300 330 366 384 366 <br /> Max continuous output power VA 240 290 325 349 380 360 <br /> Nominal(L-L)voltage/range' V 240/211-264 208/183-250 <br /> Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 <br /> IQ8 Series Microinverters Extended <br /> lfrequen Hz 60 <br /> Easytoinstall Extended frequency range Hz 50-68 <br /> Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- Lightweight and compact with AC short circuit fault current over 2 4.4 <br /> 3 cycles Arms <br /> defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors <br /> power to AC power efficiently.The brain of the semiconductor-based microinverter Power Line Communication Max units per 20A(L-L)branch circuits 16 13 11 11 10 9 <br /> • <br /> is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components Total harmonic distortion <5% <br /> microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced Overvoltage class AC port III <br /> 55nm technology with high speed digital logic and has super-fast response times Faster installation with simple <br /> two-wire cablingAC port backfeed current MA 30 <br /> to changing loads and grid events,alleviating constraints on battery sizing for home <br /> energy systems. Power factor setting 1.0 <br /> High productivity and reliability Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging <br /> Produce power even when the Peakefficiency % 97.5 97.6 97.6 97.6 97.6 97.4 <br /> • Enphase grid is down* CEC weighted efficiency % 97 97 97 97.5 97 97 <br /> More than one million cumulative Night-time power consumption mw 60 <br /> hours of testing MECHANICAL DATA <br /> Class 11 double-insulated Ambient temperature range -40°C to+60°C(-40°F to*140°F) <br /> Part of the Enphase Energy System,108 Series IQ8 Series Microinverters redefine reliability enclosure Relative humidity range 4%to10o%(condensing) <br /> Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative Optimized for the latest high- <br /> Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing•enabling an industry- DC Connector type MC4 <br /> and analysis software. leading limited warranty of upto 25 years. powered PV modules <br /> Dimensions(HxVVxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") <br /> Microgrid-forming weight 1.08 kg(2.381bs) <br /> Complies with the latest Cooling Natural convection-no fans <br /> • <br /> up::c CERTIFIED advanced grid support" Approved for wet locations yes <br /> Remote automatic updates for Pollution degree PD3 <br /> the latest grid requirements Enclosure Class II double-insulated,corrosion resistant polymeric enclosure <br /> Connect PV modules quickly and easily to I08 Series IQ8 Series Microinverters are UL Listed as Configurable to support a wide Environ.category/UV exposure rating NEMA Type 6/outdoor <br /> Microinverters usingthe included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with <br /> cable with plug-n-playMC4connectors. various regulations,when installed according to range of grid profiles r <br /> manufacturer's instructions. Meets CA Rule 21(UL 1741-SA) CA Rule 21(UL 1741-SA).UL 62109-1.UL1741/IEEE1547.FCC Part15 Class B.ICES-0003 Class B.CAN/CSA-C22.2 NO.107.1-01 <br /> requirements Certifications Thisproduct is UL Listed as PV Rapid Shut Down Equipment and conformswith NEC 2014,NEC 2017,and NEC 2020 section <br /> 690.12 and C22A-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors.when installed according to <br /> manufacturer's instructions. <br /> ®2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters,and other 'Only when installed with IQ System Controller 2,meets (1)The IQBH-208 variant will be operating in grid-tied mode only at 208V AC.(2)No enforced DC/AC ratio.See <br /> names aretrademarks of Enphase Energy,Inc.Data subjectto change. UL 1741.I08H-208V operates only in grid-tied mode. the compatibility calculator at https://Iink.enphase.com/module-compatibility(3)Maximum continuous input <br /> I08 Series Microinverters supports split phase,240V. DC current is 10.6A(4)Nominal voltage range can be extended beyond nominal if required bythe utility.(5) <br /> IQBSE-DS-0001-01-EN-US-2022-03-17 IQ8H-208 supports split phase,208V only. Limits may vary.Refer to local requirements to define the number of mic roinverters per branch 1 n your area. IQSSE-DS-0001-01-EN-US-2022-03-17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.