My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
>
Address Records
>
WETMORE AVE
>
2721
>
MARQUEE APARTMENTS
>
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2023 11:11:14 AM
Creation date
6/22/2023 9:57:45 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2721
Tenant Name
MARQUEE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 ! <br /> Plan Check Number PW1907-055 <br /> 2721 Wetmore Avenue <br /> Response to comments from First Building Review,August 26, 2019 <br /> Geotechnical <br /> Item 1 <br /> We used the foundation design criteria from the geotechnical report prepared by Associated Earth <br /> Sciences, dated May 28, 2019 as follows: <br /> a. Recommended foundation types(IBC Section 1803.6 Item 5). <br /> Ref: Page 10 <br /> b. Site class(IBC Sections 1613.3.2 and 1803.3) <br /> Ref: Page 7 <br /> c. Mapped short-period and one-second response acceleration parameters(IBC Section 1613.3.1). <br /> Ref: Supplemental Structural Calculations <br /> d. Design criteria for continuous and isolated foundations(IBC Sections 1803.6 Item 5). The criteria shall include, <br /> but are not limited to, minimum foundations sizes,allowable foundation bearing pressures including increases for <br /> short-duration loads if allowed,and required preparation of bearing soils(e.g., removal of incompetent soils, <br /> compaction of native soils, replacement of native soils with compacted structural fill, etc.). <br /> Ref: Pages 9, 10 <br /> e. Design criteria for deep foundations(IBC Sections 1803.5.5 and 1803.6 Item 5). <br /> Deep foundations not required at this site. <br /> f.Active earth,passive earth,hydrostatic,live surcharge(e.g., traffic),superimposed weight surcharge(e.g., <br /> building,soil), and seismic surcharge pressures, including factors of safety(IBC Sections 1610.1, 1803.5.12 Item <br /> 1807.1.1, 1807.2.2, and 1808.3.2). Note that while Section 14.0 addresses the seismic surcharge, the <br /> recommendation appears to provide a non-specific range of"8H to 11 H';the recommendation should be specific. <br /> We applied 35 pcf active pressure on the basement walls and used 1 H for seismic loads from <br /> Section 14. <br /> Architectural, Miscellaneous <br /> Response to these comments furnished by the Architect. <br /> Structural/General: <br /> Item 2 <br /> The structural notes on sheet S1.01 have been revised to include the geotechnical design parameters. <br /> Item 3 <br /> The structural notes on sheet S1.01 have been revised to update the deferred submittals. <br /> Page 2/S--- <br />
The URL can be used to link to this page
Your browser does not support the video tag.