Laserfiche WebLink
File: 18185 West 17 temp pump trk Pa( <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> Toe 2.748 4 .0 73.3 13. 9 89. 9 5.7 <br /> Reinf. Stress at Level 1 = 33.247 Ksi (Pullout controls. . . ) <br /> 2 = 37.307 Ksi (Pullout controls. . . ) <br /> 3 = 33.566 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 2 <br /> 2.445 8.0 52.7 7 .9 77.7 15.0 <br /> Reinf. Stress at Level 1 = 27.729 Ksi (Pullout controls. . . ) <br /> 2 = 30.794 Ksi (Pullout controls. . . ) <br /> 3 = 30.485 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 3 <br /> 2. 105 12.0 47.7 8.9 68.7 16.5 <br /> Reinf. Stress at Level 1 = 22.771 Ksi (Pullout controls. . . ) <br /> 2 = 28.027 Ksi (Pullout 'controls. . . ) <br /> 3 = 29.633 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL, TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 4 <br /> 1.478 16.0 44 . 5 15.7 66.4 12.0 <br /> Reinf. Stress at Level 1 = 14 .885 Ksi (Pullout controls. . . ) <br /> 2 = 26.300 Ks . (Pullout controls. . . ) <br /> 3 = 29.034 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 5 <br /> 1.450 20.0 42.5 16.3 54.0 13.6 <br /> Reinf. Stress at Level 1 = 12.955 Ksi (Pullout controls. . . ) <br /> 2 = 25.367 Ksi (Pullout controls. . . ) <br /> 3 = 28.650 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deq) (ft) (deg) (ft) <br /> NODE 6 <br /> 1.577 24 .0 36.3 14 . 9 47.7 17 .8 <br /> 't45. Stress at Level 1 = 8. 87Page31 41Klout controls. . . ) <br /> 2 = 22. 104 Ksi (Pullout controls. . . ) <br />