Laserfiche WebLink
File: 18185 South 13 temp Page - 3 <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> Toe 2.306 4 .0 70. 6 9. 6 78.4 4 .0 <br /> Reinf. Stress at Level 1 = 35.024 Ksi (Pullout controls. . . ) <br /> 2 = 37 .596 Ksi (Pullout controls. . . ) <br /> 3 = 33.591 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 2 <br /> 2.752 8.0 54.9 11.1 67 .7 4.2 <br /> Reinf. Stress at Level 1 = 29.008 Ksi (Pullout controls. . . ) <br /> 2 = 32.894 Ksi (Pullout controls. . . ) <br /> 3 = 31.576 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 3 <br /> 3.198 12.0 40.9 7.9 52.4 9.8 <br /> Reinf. Stress at Level 1 = 24 .680 Ksi (Pullout controls. . . ) <br /> 2 = 27 .976 Ksi (Pullout controls. . . ) <br /> 3 = 29.419 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 4 <br /> 3.462 16.0 34 .9 13.6 47.3 7. 1 <br /> Reinf. Stress at Level 1 = 19.434 Ksi (Pullout controls. . . ) <br /> 2 = 25.155 Ksi (Pullout controls. . . ) <br /> 3 = 28.259 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 5 <br /> 3. 654 20.0 21.3 10.7 42.3 13.5 <br /> Reinf. Stress at Level 1 = 14 .713 Ksi (Pullout controls. . . ) <br /> 2 = 17.459 Ksi (Pullout controls. . . ) <br /> 3 = 24 .661 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 6 <br /> 3. 807 24 .0 19.9 15.3 39. 1 12. 4 <br /> 1flf.. Stress at Level 1 9.919aW of(lcllout controls. . . ) <br /> 2 -- 15.545 Ksi (Pullout controls. . . ) <br />