Laserfiche WebLink
File: 18185 South 13 temp 2 nails Pa( <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> Toe 1.685 4 .0 66. 3 9.9 89. 9 3.9 <br /> Reinf. Stress at Level 1 = 33.848 Ksi (Pullout controls. . . ) <br /> 2 = 36.346 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE TOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 2 <br /> 1.870 8.0 54 .9 11.1 67.7 4.2 <br /> Reinf. Stress at Level 1 = 29.008 Ksi (Pullout controls. . . ) <br /> 2 = 32.894 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (St) <br /> NODE 3 <br /> 2.081 12.0 40.9 7.9 52.4 9.8 <br /> Reinf. Stress at Level 1 = 24 . 680 Ksi (Pullout controls. . . ) <br /> 2 = 27. 976 Ks` (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 4 <br /> 2.287 16.0 34 .9 13.6 47.3 7.1 <br /> Reinf. Stress at Level 1 - 19.434 Ksi (Pullout controls. . . ) <br /> 2 - 25.155 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LNGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 5 <br /> 2.506 20.0 33.0 23.9 89.9 0.0 <br /> Reinf. Stress at Level 1 = 18.186 Ksi (Pullout controls. . . ) <br /> 2 24 .243 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BE.IIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (=t) (deg) (ft) (deg) (ft) <br /> NODE 6 <br /> 2. 679 24.0 24 .3 15.8 34 . 1 11.6 <br /> Reinf. Stress at Level 1 = 12 .111 Ksi (Pullout controls. . . ) <br /> 2 = 19.014 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> 18185E FACTOR WALL TOE ANg?94I4LW)TH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br />