My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
>
Address Records
>
WETMORE AVE
>
2721
>
MARQUEE APARTMENTS
>
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2023 11:11:14 AM
Creation date
6/22/2023 9:57:45 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2721
Tenant Name
MARQUEE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Soil Nail Shotcrete Facing calcs <br /> Project#: 18185 Date: 2019/06 <br /> Project Name: Marquee Apartments Shoring <br /> Reference: FHWA IF 03 017 and FHWA SA 96 069 #8 Nail <br /> Facing flexural capacity is critical where maximum spacing and where Tavgs is greatest. <br /> Check where Tavgs is greatest. Similar at all other locations. <br /> Horiz. Spacing Sh = 5 (feet) Maximum (from output, corresponding to <br /> Vertical Spacing Sv = 4 (feet) Maximum greatest bar stress) <br /> Table 5.1 Factor Cf= 2.0 Temp Shotcrete Facing <br /> Wall Thickness h = 4 (inch) = 0.333 (feet) <br /> Vertical Rff= 230 x Cf ( a vn + a vm ) h fy nail = 75 (ksi) <br /> Horizontal Rff= 230 x Cf ( a hn + a hm ) h As nail = 0.79 (in2) <br /> #8 Nails <br /> WWF Reinf. a vm = a hm = 0.058 (in2/ft) for WWF 6x6 W2.9 x W2.9 typical <br /> a vn = a hn == 0.058 + (2 x 0.2 ) = 0.158 (in2/ft) <br /> Facing Flexural capacity, Rff 4 <br /> Rff= 230 2 0.058 + 0.158 0.333 <br /> Rff= 33.1 (kips) <br /> Wall Location: South temp with 2 nails H = 13 ft <br /> Similar Locations: Balance of South wall similar. r ,, <br /> J ., t 2, Sa <br /> Number of Rows of Nails = 2 (from output, corresponding to <br /> Max Avg Reinf greatest bar stress) <br /> Working Force Maximum Tavg s = 10.553 (kips) (from output) <br /> Tcap/ 1.8 = Tmax = 41.700 1 41.7 (kips) <br /> T nails = 33.848 1 33.848 Nail 1 <br /> (at X = 10 ft location) 36.346 0.79 28.713 Nail 2 <br /> 0.000 0.79 0.000 Nail3 <br /> 0.000 0.79 0.000 Nail 4 <br /> 0.000 0.79 0.000 Nail 5 <br /> Average Force 0.000 0.79 0.000 Nail 6 <br /> of all Soil Nails T avg = (ksi) (in2) 31.281 (kips) <br /> T max s = 10.553 x 41.700 1 31.281 = 14.068 <br /> Force at Soil Nail <br /> Head T o= 14.068 x 0.714 = 10.045 (kips) <br /> Facing; Factor of Safety (FS) = Rff = 33.1 = 3.30 <br /> (FS min = 1.5) To 10.045 OK <br /> ,, <br /> 181856 Page 96 of 180 <br />
The URL can be used to link to this page
Your browser does not support the video tag.