File: 18185 East 12 temp Page - 3 <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> Toe 1.910 4 .0 60. 9 8.2 89. 9 4 .8 <br /> Reinf. Stress at Level 1 = 26.385 Ksi (Pullout controls. . . ) <br /> 2 = 31. 619 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 2 <br /> 2.082 8.0 52.1 9.1 63.4 5.4 <br /> Reinf. Stress at Level 1 = 21 .591 Ksi (Pullout controls. . . ) <br /> 2 = 30.713 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLAN', PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 3 <br /> 2.143 12.0 40.6 11.1 53.1 6.0 <br /> Reinf. Stress at Leve:. 1 = 14.394 Ksi (Pullout controls. . . ) <br /> 2 = 29. 610 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 4 <br /> 2.250 16.0 32.7 13.3 45.0 6.8 <br /> Reinf. Stress at Level 1 = 7.197 Ks:i. (Pullout controls. . . ) <br /> 2 = 28.865 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 5 <br /> 2.350 20.0 27 .7 18.1 42 .0 5.4 <br /> Reinf. Stress at Level. 1 = 0.000 Ksi <br /> 2 = 28 .377 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 6 <br /> 2.540 24.0 26. 6 26.8 89. 9 0.0 <br /> Reinf. Stress at Level 1 = 0.000 Ksi <br /> 2 = 28.264 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> 18185E FACTOR WALL TOE ANiG406114 8fTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br />