Laserfiche WebLink
File: 18185 North 18 temp 2 nails Pa< <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> Toe 1 .739 4 .0 66.3 9. 9 89.9 3.9 <br /> Reinf. Stress at Level 1 = 33.848 Ksi (Pullout controls. . . ) <br /> 2 = 41.108 ksi (Punching Shear controls. . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY 3EHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 2 <br /> 1. 992 8.0 47.3 7 .1 67.7 8. 4 <br /> Reinf. Stress at Level 1 = 2.9.008 Ksi (Pullout controls. . . ) <br /> 2 = 36.046 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 3 <br /> 2.278 12.0 42. 9 11 .5 55.3 6.3 <br /> Reinf. Stress at Level 1 = 24 . 130 Ksi (Pullout controls. . . ) <br /> 2 = 34 .488 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY B;;HIND PLANE PLANE <br /> FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 4 <br /> 2. 484 16.0 34. 9 13.6 47.3 7.1 <br /> Reinf. Stress at Level 1 = 19.434 Ksi (Pullout controls. . . ) <br /> 2 = 31.241 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WALL TOE • ANGLE LENGTH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br /> NODE 5 <br /> 2.709 20.0 26.0 8.9 37.2 15.1 <br /> Reinf. Stress at Level. 1 16.525 Ksi (Pullout controls. . . ) <br /> 2 = 27 .007 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> FACTOR WAIF:, TOE ANGLE LENGTH ANGLE LENGTH <br /> (It) (dog) (ft) (deg) (ft) <br /> NODE 6 <br /> 2.892 24.0 22.1 10.4 32.3 17. E <br /> Reinf. Stress at Level 1 12. 989 Ksi (Pullout controls. . . ) <br /> 2 - 24 .061 Ksi (Pullout controls. . . ) <br /> MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE <br /> SAFETY BEHIND PLANE PLANE <br /> 18185E FACTOR WALL TOE ANi3+$E17 Ag.)TH ANGLE LENGTH <br /> (ft) (deg) (ft) (deg) (ft) <br />