i. Sheet C1.0 <br /> ii. Sheet C2.0 <br /> iii. Sheet C3.0 <br /> iv. Sheet C4.0 <br /> v. Sheet C4.1 (11x17 from Traffic Reviewer) <br /> vi. Sheet C5.0 <br /> 3. The comments below were generated from this project's Street Light Reviewer. If you have any questions <br /> regarding these comments, please contact Corey Hert with the City of Everett Planning Department(425- <br /> 257-8887 or CHert@everettwa.gov). <br /> a. Installation of the sidewalk along the project's street frontage will require adjustments to and <br /> installation of conduits,junction boxes and wiring for the City's street lighting and flashing <br /> ‘13 C beacon systems.All sidewalks must have an accessible ADA compliant pedestrian path that <br /> provides a minimum of 4'width free of obstructions(street light poles, signs, etc). <br /> b. The lighting system shall be upgraded to meet current City Standards and Electrical Code <br /> regarding depth of conduit burial,junction box cover non-slip surface treatment, conduit size, <br /> conduit type and number,conductor size and number,grounding and bonding, pole type, pole <br /> location, etc. Record drawings for the flashing beacon system and illumination system are <br /> f available upon request. The proponent will need to field as-built the existing systems and show <br /> kt) it in the plans, including any modifications. A spare 2" conduit shall be installed along the <br /> frontage and be terminated in new junction boxes at either end of the frontage for future use. <br /> We anticipate the wiring to be in conduit, but any direct bury conductors shall be replaced with <br /> #6 USE conductors in 2" conduit. Any junction boxes without non-slip lids or frames will need to <br /> be upgraded to new boxes with non-slip lid and load bearing base section. Light poles within 2'- <br /> 6" of the face of curb need to be relocated with new foundation (3'-6" CL of pole to face of curb <br /> desired). The City's typical installation involves LED cobra head fixtures on steel or aluminum <br /> poles, 30-35 feet mounting height, with an appropriate length mast arm matching same type or <br /> style.Within the Central Business District, pedestrian level decorative poles and LED fixtures are <br /> required. Given the length of frontage,three decorative light standards are required. Revised <br /> lighting system details shall be provided on the plans. <br /> c. For the overhead beacons and pole,the crosswalk is closed and the contractor on-site has <br /> requested to remove mast arm as an overhead obstruction. Disconnect the existing system and <br /> G • remove both the pole and vertical shaft from the foundation and protect the anchor bolts. The <br /> pole and shaft can be stored at the secured City of Everett Railway Ave storage facility until it is <br /> ` ready to reinstall. The existing light standard should also be removed and delivered to the <br /> Railway Ave yard,the City will provide a new or near-new pole to place on the foundation when <br /> the work is complete.The City will take possession of the LED fixture and will store it until the <br /> pole is reinstalled. The proponent is responsible for any wiring or splicing to reconnect the <br /> beacon system and light standard to make it fully functional. If the grade of the foundations <br /> need to change, or the excavation undermines the foundations, they shall be replaced in their <br /> entirety. <br /> d. Existing round steel sign posts shall be converted to square perforated posts with concrete <br /> - foundations meeting City Standards.Signs shall be relocated, or replaced sized to MUTCD <br /> requirements. Consult with the City Traffic Engineering Department for detailed requirements. <br /> 0 3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett, WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Fage2of 3 <br />