My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
>
Address Records
>
WETMORE AVE
>
2721
>
MARQUEE APARTMENTS
>
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2023 11:11:14 AM
Creation date
6/22/2023 9:57:45 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2721
Tenant Name
MARQUEE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Envelope Requirem,..its Summary, pg 2 ENV-REQ &1/tI <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Oct 2017 <br /> Definitions: <br /> Ls=Liner system--A continuous membrane installed below the purlins and uninterrupted by framing members.Uncompressed,unfaced <br /> insulation rests on top of the membrane between the purlins.Refer to Section Al 02.2.5.4. <br /> c.i.=Continuous insulation--Insulation that is continuous across all structural members without thermal bridges other than service <br /> openings and penetrations by metal fasteners with a x-sectional area of less than 0.04°ro of the opaque surface area of the assembly. <br /> Components with more than 0.04%metal penetrations may be eligible to follow the alternate CI values below. <br /> nit=Intermediate framing--Includes insulated headers,corners and interior partition wall to exterior wall intersections.Refer to Section <br /> A 103.2 for framing definitions. <br /> Footnote Summary: <br /> Each table in the 2015 WSEC has footnotes applicable to specific information provided in the table.This footnote summary provides only <br /> abbreviated details from these footnotes. Refer to 2015 WSEC for completefootnote information. <br /> Note 1 -Assembly descriptions can be found in Chapter 2 and Appendix A. <br /> Note 2-Use of assembly U-factors.C-factors and F-factors from Appendix A and Chapter 3 are required unless otherwise allowed <br /> by the provisions of this Code. <br /> Note 3-For metal building roofs where using R-value compliance method,a thermal spacer block with minimum thickness of 1/2-inch <br /> and minimum R-value of R-3.5 is required.Otherwise use the U-factor compliance method. <br /> Note 4-Where heated slabs are below-grade,they shall comply with the F-factor requirements for slab-on-grade heated slabs. <br /> Note 5-Heated slab F-factors shall be determined specifically for heated slabs.Unheated slab F-factors shall not be used. <br /> Note 6-CMU walls in all occupancies other than Group R may be eligible for reduced insulation if all provisions stated in applicable <br /> footnote are met.Refer to Footnote D in Table C402.1.4 or Footnote C in Table C402.1.3 for eligibility requirements. <br /> Note 7-Components with continuous insulation but with metal penetrations/connections may be eligible for alternate continuous <br /> insulation R-values if all provisions in applicable footnote are met. Refer to alternate prescriptive R-values in table below <br /> and Footnote G in Table C402.1.3 for eligibility requirements. <br /> Alternate continuous insulation nominal R-values <br /> This alternate nominal R-value compliance option is allowed for projects complying with all of the following: <br /> 1.The ratio of the cross-sectional area,as measured in the plane of the surface,of metal penetrations of otherwise continuous <br /> insulation to the opaque surface area of the assembly is greater than 0.0004(0.04%),but less than 0.0012(0.12%). <br /> 2.The metal penetrations of otherwise continuous insulation are isolated or discontinuous(e.g.,brick ties or other <br /> discontinuous metal attachments,offset brackets supporting shelf angles that allow insulation to go between the shelf <br /> angle and the primary portions of the wall structure).No continuous metal elements(e.g.,metal studs.z-girts,z-channels, <br /> shelf angles)penetrate the otherwise continuous portion of the insulation. <br /> 3.Building permit drawings shall contain details showing the locations and dimensions of all the metal penetrations(e.g.. <br /> brick ties or other discontinuous metal attachments,offset brackets.etc.)of otherwise continuous insulation.In addition. <br /> calculations shall be provided showing the ratio of the cross-sectional area of metal penetrations of otherwise continuous <br /> Assemblies with Alternate option for assemblies with alternate option for assemblies with <br /> continuous metal penetrations,greater than metal penetrations,greater than or <br /> insulation(see 0.0 thti but less than 0.0841 equal to 0.034 but less than 0.124e <br /> definition) <br /> R-9.5a R-119c: R-13c: <br /> R-114ci R-14.3c R-15.'ci <br /> R-13_3ci F.-15.6c F,18.3c: <br /> R-1: P.-21c: <br /> R-30ci ?.- <br /> R-13—R-'.5c =-13—F.-£.4c F-13— 10.3c: <br /> P-13—R-10ci F-1:—F.-12 5c: R-13—R-13.8c: <br /> R--- —R-1..5c R-13—F.-15 6c. F-13 17.2c: <br /> P.-:3—R-13ci R-13—R-1fi 5c: P.-13— <br /> R-1P—R-S.Sci R-19—R-1 v.6 R-19— 11.7c: <br /> P_-:9—F.-l4c: R 19—R-1 R-19— <br /> R-19—R-16ci R-19—R20:: R-19 <br /> R-20—R-3.8c: ;-20—R—t.8c R-20.—P-5.3ci <br /> R-21—=-5c: 21—R-6.3c: 21 <br /> End of Envelope Requirements Summary <br />
The URL can be used to link to this page
Your browser does not support the video tag.