My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
>
Address Records
>
WETMORE AVE
>
2721
>
MARQUEE APARTMENTS
>
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2023 11:11:14 AM
Creation date
6/22/2023 9:57:45 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2721
Tenant Name
MARQUEE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. ZL/ <br /> Vertical Fenestration Target Area Adjustment Calculations <br /> Project Title: Marquee Apartments Date 0 3/14/2 019 <br /> If vertical fenestration area exceeds maximum allowed per Section C402.4.1.then Target Area Adjustment of all applicable envelope elements is <br /> required. This worksheet automatically calculates these adjustments and updates target areas in the ENV-UA and ENV-SHGC worksheets. Information <br /> shown in this worksheet is for reference only and is write-protected. Submit this Target Area Adjustment form with ENV-UA and ENV-SHGC forms. <br /> VF=Vertical fenestration NW=Net above grade wall(excludes fenestration and doors.) <br /> DR=Opaque doors Gross Exterior Above-Grade Wall Area=VF+NW+DR <br /> AG=Above-grade <br /> Proposed Areas Vertical Fenestration Net Above Grade Wall Opaque Door <br /> Project Areas-> VF= 10464.0 NW= 28756.0 DR= 168.0 <br /> Existing Non-project Areas-> VF= NW= <br /> Gross Exterior Max Vert.Fen.% Maximum Target <br /> AG Wall Area (C402.3.1) Vert.Fen,Area <br /> 39388.0 x 30.0% - 100 = I 11816.4 <br /> Total Vertical Delta Vertical Excess Vertical <br /> / <br /> Fenestration Maximum Target Fenestration 0 Fenestration <br /> 10464.0 - 11816.4 = -1352.4 II greater = <br /> �3 -1352.4 Z Multiplier applied to all <br /> Project Vertical Excess Vertical Target Vertical Total Vertical <br /> / Proposed Vertical <br /> Fenestration Fenestration Fenestration Fenestration Target VF Multiplier Fenestration Areas to <br /> calculate Target Vertical <br /> 10464.0 - = 10464.0 - 10464.0 = 1.00 Fenestration Area <br /> Net AG Wall Area Excess Fenestration Target Net Wall Area Net Wall Target Net Wall Mult. Multiplier applied to all <br /> 28756.0 + = 28756.0 - 28756.0 = 1.00 Proposed Opaque Above- <br /> Grade Wall Areas to <br /> Tar et Areas - lift calculate Target Above- <br /> Target Grade Wall Area <br /> Commercial <br /> Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> Non-metal frame 9584.0 x 1.00 = 9584.0 <br /> Metal frame,fixed 859.0 x 1.00 = 859.0 <br /> =Metal frame,operable X <br /> Metal frame.entrance door 21.0 X 1.00 = 21.0 Target areas in shaded <br /> Above-grade Wall Proposed Area Target Net Wall Mult. Target Area boxes are applied to <br /> Steel Frame 232.0 , x 1.00 = 232.0 target areas on ENV-UA <br /> Metal Building , X = <br /> Wood/Otherframe 24106.0 x 1.00 = 24106.0 <br /> Mass 3820.0 x 1.00 = 3820.0 <br /> Mass Transfer Deck 5 9 8.0 x 1.0 0 = 598.0 <br /> Group R Mass X = <br /> 39220.0 Sum of Target 39220.0 Sum of target above-grade <br /> Sum of Proposed <br /> 9 wall and vertical <br /> fenestration areas are <br /> Target Areas - SHGC x A calculated to equal the <br /> sum of proposed <br /> Non-North Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> PF<0.2 9455.0 x 1.00 = 9455.0 <br /> 0.25PF<0.5 X = <br /> PF a 0.5 X = SHGC target areas in <br /> shaded boxes are applied <br /> North Vertical Fenestration <br /> to target areas on ENV- <br /> PF<0.2 _ 1009.0 X 1.00 - 1009.0 SHGC <br /> 0.25PF<0.5 X = <br /> PF a 0.5 X = <br />
The URL can be used to link to this page
Your browser does not support the video tag.