Laserfiche WebLink
. ZL/ <br /> Vertical Fenestration Target Area Adjustment Calculations <br /> Project Title: Marquee Apartments Date 0 3/14/2 019 <br /> If vertical fenestration area exceeds maximum allowed per Section C402.4.1.then Target Area Adjustment of all applicable envelope elements is <br /> required. This worksheet automatically calculates these adjustments and updates target areas in the ENV-UA and ENV-SHGC worksheets. Information <br /> shown in this worksheet is for reference only and is write-protected. Submit this Target Area Adjustment form with ENV-UA and ENV-SHGC forms. <br /> VF=Vertical fenestration NW=Net above grade wall(excludes fenestration and doors.) <br /> DR=Opaque doors Gross Exterior Above-Grade Wall Area=VF+NW+DR <br /> AG=Above-grade <br /> Proposed Areas Vertical Fenestration Net Above Grade Wall Opaque Door <br /> Project Areas-> VF= 10464.0 NW= 28756.0 DR= 168.0 <br /> Existing Non-project Areas-> VF= NW= <br /> Gross Exterior Max Vert.Fen.% Maximum Target <br /> AG Wall Area (C402.3.1) Vert.Fen,Area <br /> 39388.0 x 30.0% - 100 = I 11816.4 <br /> Total Vertical Delta Vertical Excess Vertical <br /> / <br /> Fenestration Maximum Target Fenestration 0 Fenestration <br /> 10464.0 - 11816.4 = -1352.4 II greater = <br /> �3 -1352.4 Z Multiplier applied to all <br /> Project Vertical Excess Vertical Target Vertical Total Vertical <br /> / Proposed Vertical <br /> Fenestration Fenestration Fenestration Fenestration Target VF Multiplier Fenestration Areas to <br /> calculate Target Vertical <br /> 10464.0 - = 10464.0 - 10464.0 = 1.00 Fenestration Area <br /> Net AG Wall Area Excess Fenestration Target Net Wall Area Net Wall Target Net Wall Mult. Multiplier applied to all <br /> 28756.0 + = 28756.0 - 28756.0 = 1.00 Proposed Opaque Above- <br /> Grade Wall Areas to <br /> Tar et Areas - lift calculate Target Above- <br /> Target Grade Wall Area <br /> Commercial <br /> Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> Non-metal frame 9584.0 x 1.00 = 9584.0 <br /> Metal frame,fixed 859.0 x 1.00 = 859.0 <br /> =Metal frame,operable X <br /> Metal frame.entrance door 21.0 X 1.00 = 21.0 Target areas in shaded <br /> Above-grade Wall Proposed Area Target Net Wall Mult. Target Area boxes are applied to <br /> Steel Frame 232.0 , x 1.00 = 232.0 target areas on ENV-UA <br /> Metal Building , X = <br /> Wood/Otherframe 24106.0 x 1.00 = 24106.0 <br /> Mass 3820.0 x 1.00 = 3820.0 <br /> Mass Transfer Deck 5 9 8.0 x 1.0 0 = 598.0 <br /> Group R Mass X = <br /> 39220.0 Sum of Target 39220.0 Sum of target above-grade <br /> Sum of Proposed <br /> 9 wall and vertical <br /> fenestration areas are <br /> Target Areas - SHGC x A calculated to equal the <br /> sum of proposed <br /> Non-North Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> PF<0.2 9455.0 x 1.00 = 9455.0 <br /> 0.25PF<0.5 X = <br /> PF a 0.5 X = SHGC target areas in <br /> shaded boxes are applied <br /> North Vertical Fenestration <br /> to target areas on ENV- <br /> PF<0.2 _ 1009.0 X 1.00 - 1009.0 SHGC <br /> 0.25PF<0.5 X = <br /> PF a 0.5 X = <br />