Laserfiche WebLink
SHGC SHGC <br /> 2015 WSEC Compliance FormsCalculation ENV for Commercial Buildings including R2,R3,&R4 over 3 stories and all RI Rev-ised Oct 2017 <br /> Project Title: Marquee Apartments Date 03/14/2019 <br /> Target Insulation Allowance: For Building Department Use <br /> Fully Conditioned Space-Commercial,Group R,Mixed Use <br /> Fenestration Area as%gross above-grade wall area Max.Target: 30.0% <br /> Skylight Area as%gross roof area Max.Target: 5.0% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes:1-Proposed vertical fenestration and skylight areas entered in ENV-SHGC must match proposed <br /> fenestration areas in ENV-UA. <br /> 2-If Target Area Adjustment is required per ENV-UA.then target areas will be automatically <br /> adjusted in ENV-SHGC.Refer to Target Area Adjustments worksheet for this calculation. <br /> 3-Fenestration assembly SHGC shall be the manufacturer's NFRC product rating,or shall be the <br /> default value per Section C303.1.3. <br /> 4-Fenestration that separates conditioned space from a non-conditioned space shall be included in this worksheet. User Note <br /> Enter target SHGC values for this fenestration under proposed SHGC,so it is neutral to the calculation. <br /> Skylights Proposed SHGC Target SHGC <br /> Sch.ID I Provide SHGC source and fenestration schedule ID SHGC x Area(A) SHGC x A SHGC x Area(A)= SHGC x A <br /> 0.35 <br /> SHGC 0.35 <br /> II <br /> Skylight Totals! <br /> All Non-North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF <br /> Sch.ID Provide SHGC source and fenestration schedule ID PF SHGC x Area(A) SHGC x A Category SHGC x Area(A)= SHGC x A <br /> A-03 1Manufacturer's chart-attached 0 0.28 422 118 PF<0.2 0.40 9455 3782.0 <br /> A-06 1 Manufacturer's chart-attached 0 0.27 264 71 0.25PF<0.5 0.48 <br /> Balcony <br /> 0 0.40 2580 1032 PF z 0.5 I 0.64 <br /> Door j <br /> F-01 0 0.24 893 214 ++If projection factor(PF)credits are <br /> F-02 0 0.24 850 204 applied to the proposed design, Target <br /> F-03 0 0.24 1275 306 SHGC will sum fenestration area by PF <br /> F-04 0 0.24 2380 <br /> 571 category. <br /> F-05 0 0.24 597 143 <br /> Lobby Door, <br /> side Manufacturer's chart-attached 0 0.25 104 26 <br /> Lobby <br /> op bY Door Manufacturer's chart-attached 0 0.24 69 17 <br /> Lobby Door j 0 0.24 21 5 <br /> +If PF credit is applied,then vertical fenestration Non-North Window Totals 9455.0 2707.8 9455.0 3782.0 <br /> must be entered in the correct table according to <br /> orientation. If credit is not applied then all vertical <br /> fenestration can be entered in either table. <br /> North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF SHGC x Area(A)*SHGC x A PF SHGC x Area(A)= SHGC x A <br /> Sch.ID Provide SHGC source and fenestration schedule ID ; Category <br /> F-01 0 0.24 510 122 PF<0.2 0.53 1009 534.8 <br /> F-03 0 0.24 255 61 0.25PF<0.5 0.58 <br /> F-05 0 0.24 46 11 PF z 0.5 0.64 <br /> Balcony 0 0.40 198 79 ++If projection factor(PF)credits are applied <br /> Door to the proposed design, Target SHGC will <br /> sum fenestration area by PF category. <br /> North Window Totals 1009.0 273.8 1009.0 534.8 <br /> Area I SHGC x AI Area II I SHGC x A <br /> TO COMPLY-The Proposed Total SHGC x A <br /> shall not exceed the Target Total SHGC x A. Total(Skylight+Window) 10464.0 2981.7 10464.0 4316.8 <br />