My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
>
Address Records
>
WETMORE AVE
>
2721
>
MARQUEE APARTMENTS
>
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2023 11:11:14 AM
Creation date
6/22/2023 9:57:45 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2721
Tenant Name
MARQUEE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHGC SHGC <br /> 2015 WSEC Compliance FormsCalculation ENV for Commercial Buildings including R2,R3,&R4 over 3 stories and all RI Rev-ised Oct 2017 <br /> Project Title: Marquee Apartments Date 03/14/2019 <br /> Target Insulation Allowance: For Building Department Use <br /> Fully Conditioned Space-Commercial,Group R,Mixed Use <br /> Fenestration Area as%gross above-grade wall area Max.Target: 30.0% <br /> Skylight Area as%gross roof area Max.Target: 5.0% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes:1-Proposed vertical fenestration and skylight areas entered in ENV-SHGC must match proposed <br /> fenestration areas in ENV-UA. <br /> 2-If Target Area Adjustment is required per ENV-UA.then target areas will be automatically <br /> adjusted in ENV-SHGC.Refer to Target Area Adjustments worksheet for this calculation. <br /> 3-Fenestration assembly SHGC shall be the manufacturer's NFRC product rating,or shall be the <br /> default value per Section C303.1.3. <br /> 4-Fenestration that separates conditioned space from a non-conditioned space shall be included in this worksheet. User Note <br /> Enter target SHGC values for this fenestration under proposed SHGC,so it is neutral to the calculation. <br /> Skylights Proposed SHGC Target SHGC <br /> Sch.ID I Provide SHGC source and fenestration schedule ID SHGC x Area(A) SHGC x A SHGC x Area(A)= SHGC x A <br /> 0.35 <br /> SHGC 0.35 <br /> II <br /> Skylight Totals! <br /> All Non-North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF <br /> Sch.ID Provide SHGC source and fenestration schedule ID PF SHGC x Area(A) SHGC x A Category SHGC x Area(A)= SHGC x A <br /> A-03 1Manufacturer's chart-attached 0 0.28 422 118 PF<0.2 0.40 9455 3782.0 <br /> A-06 1 Manufacturer's chart-attached 0 0.27 264 71 0.25PF<0.5 0.48 <br /> Balcony <br /> 0 0.40 2580 1032 PF z 0.5 I 0.64 <br /> Door j <br /> F-01 0 0.24 893 214 ++If projection factor(PF)credits are <br /> F-02 0 0.24 850 204 applied to the proposed design, Target <br /> F-03 0 0.24 1275 306 SHGC will sum fenestration area by PF <br /> F-04 0 0.24 2380 <br /> 571 category. <br /> F-05 0 0.24 597 143 <br /> Lobby Door, <br /> side Manufacturer's chart-attached 0 0.25 104 26 <br /> Lobby <br /> op bY Door Manufacturer's chart-attached 0 0.24 69 17 <br /> Lobby Door j 0 0.24 21 5 <br /> +If PF credit is applied,then vertical fenestration Non-North Window Totals 9455.0 2707.8 9455.0 3782.0 <br /> must be entered in the correct table according to <br /> orientation. If credit is not applied then all vertical <br /> fenestration can be entered in either table. <br /> North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF SHGC x Area(A)*SHGC x A PF SHGC x Area(A)= SHGC x A <br /> Sch.ID Provide SHGC source and fenestration schedule ID ; Category <br /> F-01 0 0.24 510 122 PF<0.2 0.53 1009 534.8 <br /> F-03 0 0.24 255 61 0.25PF<0.5 0.58 <br /> F-05 0 0.24 46 11 PF z 0.5 0.64 <br /> Balcony 0 0.40 198 79 ++If projection factor(PF)credits are applied <br /> Door to the proposed design, Target SHGC will <br /> sum fenestration area by PF category. <br /> North Window Totals 1009.0 273.8 1009.0 534.8 <br /> Area I SHGC x AI Area II I SHGC x A <br /> TO COMPLY-The Proposed Total SHGC x A <br /> shall not exceed the Target Total SHGC x A. Total(Skylight+Window) 10464.0 2981.7 10464.0 4316.8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.