Laserfiche WebLink
Building Permit Plans Checklist, pg. 1 ENV-CHK <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Oct 2017 <br /> Project Title: Marquee Apartments Date 0 3/14/2 019 <br /> The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State <br /> Energy Code,Commercial Provisions. <br /> Applicability Code Location in Building <br /> (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes <br /> SCOPE <br /> Identify low energy spaces on plans;include project information,and <br /> C402.1.1 Low energy spaces calculations if applicable.that demonstrate spaces are eligible for <br /> envelope provisions exemption <br /> Identify semi-heated spaces on plans.include calculations that <br /> C402.1.1.1 Semi-heated spaces demonstrate spaces are eligible for wall insulation exemption <br /> Provide building area.average wall and roof U-factor,and installed <br /> C402.1.2 Equipment Buildings equipment information that demonstrates equipment building is eligible for <br /> envelope provision exemption <br /> Walk-in and <br /> C410.2 warehouse cooler Identify walk-in and warehouse cooler and freezer spaces on plans <br /> and freezer spaces <br /> C101.4.1 Mixed occupancy Identify spaces with different occupancy requirements on plans <br /> Identify on plans existing unconditioned spaces changing to semi-heated <br /> Change of space or conditioned space,and existing semi-heated spaces changing to <br /> C503.2 conditioning conditioned space;provide calculations for existing and final level of space <br /> conditioning.and calculations that demonstrate alteration complies with <br /> current WSEC <br /> Identify on plans existing F,S and U-occupancy spaces undergoing a <br /> change in occupancy;provide calculations that demonstrate alteration . <br /> complies with the current WSEC <br /> Change of Identify on plans pre-2002 Group R spaces undergoing a change to a <br /> C505.1 commercial occupancy;provide calculations that demonstrate alteration <br /> occupancy complies with the current WSEC <br /> Identify on plans non-Group R occupancy spaces undergoing a change to <br /> Group R;provide calculations that demonstrate alteration complies with <br /> the current WSEC <br /> ENVELOPE PROVISIONS <br /> Indicate envelope insulation compliance path and provide applicable <br /> C103.2 Compliance forms;ENV-PRESCRIPTIVE or ENV-UA/ENV-SHGC for component <br /> C103.6.3 documentation If complying via total building performance,provide a list of all proposed <br /> envelope component types,areas and U-values <br /> C303.1.1 Insulation Indicate identification mark shall be applied to all insulation materials and <br /> C303.1.2 identification insulation installed such that the mark is readily observable during <br /> inspection <br /> C303.1.3 Fenestration product Fenestration products shall be labeled with rated U-factor.SHGC,VT,and <br /> C402.4.3 rating leakage rating <br /> Indicate installation methods,thicknesses,densities and clearances to <br /> C303.1.1 General insulation achieve the intended R-value of all insulation materials: <br /> C402.2.1 installation Where two or more layers of rigid insulation will be used,indicate that <br /> edge joints between layers are staggered <br /> Indicate R-value(s)of cavity/continuous insulation on roof sections; <br /> Indicate framing materials on roof sections; <br /> Indicate method of framing for ceilings below vented attics and vaulted <br /> ceilings per A102.2(std,adv): <br /> C103.2 Roof assembly Provide area weighted average U-factor calculation for insulation whose <br /> C402.2.2 insulation thickness varies by 1 inch or less; <br /> Indicate effective U-factors of tapered insulation entirely above deck per <br /> A102.2.6;include roof configuration and slope,maximum R-value at peak <br /> and minimum R-value at low point for all roof surfaces <br /> Indicate R-values for thermal spacers and each insulation layer,and liner <br /> system(LS)method for metal building roofs <br /> C402.2.2 Skylight curb Indicate curb insulation R-value on roof section if not included in skylight <br /> insulation NFRC rating <br /> Indicate R-value(s)of cavity/continuous insulation on wall sections; <br /> Indicate framing materials on wall sections; <br /> Indicate method of framing for wood construction per A103.2(std,int,adv); <br /> C103.2 <br /> C402.2.3 Above/below grade Indicate material density category,wall weight and heat capacity for <br /> C402.2.4 wall insulation qualifying mass walls; <br /> C303.2.1 For qualifying ASTM C90 masonry walls,indicate loose-fill core insulation <br /> material and percentage of cores filled including grouted cores,bond <br /> beams,vertical fills,headers and any other grouted cores: <br />