My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
>
Address Records
>
WETMORE AVE
>
2721
>
MARQUEE APARTMENTS
>
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2023 11:11:14 AM
Creation date
6/22/2023 9:57:45 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2721
Tenant Name
MARQUEE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Building Permit Plans Checklist, pg. 1 ENV-CHK <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Oct 2017 <br /> Project Title: Marquee Apartments Date 0 3/14/2 019 <br /> The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State <br /> Energy Code,Commercial Provisions. <br /> Applicability Code Location in Building <br /> (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes <br /> SCOPE <br /> Identify low energy spaces on plans;include project information,and <br /> C402.1.1 Low energy spaces calculations if applicable.that demonstrate spaces are eligible for <br /> envelope provisions exemption <br /> Identify semi-heated spaces on plans.include calculations that <br /> C402.1.1.1 Semi-heated spaces demonstrate spaces are eligible for wall insulation exemption <br /> Provide building area.average wall and roof U-factor,and installed <br /> C402.1.2 Equipment Buildings equipment information that demonstrates equipment building is eligible for <br /> envelope provision exemption <br /> Walk-in and <br /> C410.2 warehouse cooler Identify walk-in and warehouse cooler and freezer spaces on plans <br /> and freezer spaces <br /> C101.4.1 Mixed occupancy Identify spaces with different occupancy requirements on plans <br /> Identify on plans existing unconditioned spaces changing to semi-heated <br /> Change of space or conditioned space,and existing semi-heated spaces changing to <br /> C503.2 conditioning conditioned space;provide calculations for existing and final level of space <br /> conditioning.and calculations that demonstrate alteration complies with <br /> current WSEC <br /> Identify on plans existing F,S and U-occupancy spaces undergoing a <br /> change in occupancy;provide calculations that demonstrate alteration . <br /> complies with the current WSEC <br /> Change of Identify on plans pre-2002 Group R spaces undergoing a change to a <br /> C505.1 commercial occupancy;provide calculations that demonstrate alteration <br /> occupancy complies with the current WSEC <br /> Identify on plans non-Group R occupancy spaces undergoing a change to <br /> Group R;provide calculations that demonstrate alteration complies with <br /> the current WSEC <br /> ENVELOPE PROVISIONS <br /> Indicate envelope insulation compliance path and provide applicable <br /> C103.2 Compliance forms;ENV-PRESCRIPTIVE or ENV-UA/ENV-SHGC for component <br /> C103.6.3 documentation If complying via total building performance,provide a list of all proposed <br /> envelope component types,areas and U-values <br /> C303.1.1 Insulation Indicate identification mark shall be applied to all insulation materials and <br /> C303.1.2 identification insulation installed such that the mark is readily observable during <br /> inspection <br /> C303.1.3 Fenestration product Fenestration products shall be labeled with rated U-factor.SHGC,VT,and <br /> C402.4.3 rating leakage rating <br /> Indicate installation methods,thicknesses,densities and clearances to <br /> C303.1.1 General insulation achieve the intended R-value of all insulation materials: <br /> C402.2.1 installation Where two or more layers of rigid insulation will be used,indicate that <br /> edge joints between layers are staggered <br /> Indicate R-value(s)of cavity/continuous insulation on roof sections; <br /> Indicate framing materials on roof sections; <br /> Indicate method of framing for ceilings below vented attics and vaulted <br /> ceilings per A102.2(std,adv): <br /> C103.2 Roof assembly Provide area weighted average U-factor calculation for insulation whose <br /> C402.2.2 insulation thickness varies by 1 inch or less; <br /> Indicate effective U-factors of tapered insulation entirely above deck per <br /> A102.2.6;include roof configuration and slope,maximum R-value at peak <br /> and minimum R-value at low point for all roof surfaces <br /> Indicate R-values for thermal spacers and each insulation layer,and liner <br /> system(LS)method for metal building roofs <br /> C402.2.2 Skylight curb Indicate curb insulation R-value on roof section if not included in skylight <br /> insulation NFRC rating <br /> Indicate R-value(s)of cavity/continuous insulation on wall sections; <br /> Indicate framing materials on wall sections; <br /> Indicate method of framing for wood construction per A103.2(std,int,adv); <br /> C103.2 <br /> C402.2.3 Above/below grade Indicate material density category,wall weight and heat capacity for <br /> C402.2.4 wall insulation qualifying mass walls; <br /> C303.2.1 For qualifying ASTM C90 masonry walls,indicate loose-fill core insulation <br /> material and percentage of cores filled including grouted cores,bond <br /> beams,vertical fills,headers and any other grouted cores: <br />
The URL can be used to link to this page
Your browser does not support the video tag.