Laserfiche WebLink
S 0 <br /> AUDAVIS Paul Davis Restoration of West King County <br /> 15004 35th Ave W Suite A <br /> Lynnwood,WA 98087 <br /> #425-486-5362 <br /> _ <br /> 1'E1--9'2"_f4'7^ <br /> r Dining Room Height:8' 4" <br /> ii - D ° Room _ 1 373.67 SF Walls 242.50 SF Ceiling <br /> o �,9„� P 616.17 SF Walls&Ceiling 242.50 SF Floor <br /> n`°, '411 , 26.94 SY Flooring 47.67 LF Floor Perimeter <br /> ^'Y-3'-I1-3V1-3'-11-3'. y 62.33 LF Ceil.Perimeter <br /> 4 111„ <br /> F4'4"�-11'11"--1 <br /> H-8'4"--1 <br /> �8'1"-� <br /> Door 2' 6"X 6' 8" Opens into HALLWAY <br /> Missing Wall-Goes to Floor 9'2" X 6' 8" Opens into LIVING_ROOM <br /> Door 3'X 6'8" Opens into KITCHEN2 <br /> Window 3'X 4' Opens into Exterior <br /> Window 3' X 4' Opens into Exterior 3 <br /> Window 3'X 4' Opens into Exterior <br /> Window 3'X 4' Opens into Exterior <br /> DESCRIPTION QTY REMOVE REPLACE TAX O&P TOTAL <br /> WALL <br /> 100. Two coat plaster over metal lath 616.17 SF 0.00 8.47 613.75 1,043.80 6,876.51 <br /> 101. Batt insulation replacement per 22.00 LF 0.00 1.61 4.16 7.08 46.66 <br /> LF-4"-up to 2'tall <br /> 102. Plasterer-per hour 8.00 HR 0.00 89.54 84.24 143.26 943.82 <br /> 103. Batt insulation-4"-R13-paper 373.67 SF 0.00 0.82 36.04 61.28 403.73 <br /> faced <br /> 104. Seal the walls and ceiling w/PVA 616.17 SF 0.00 0.53 38.40 65.32 430.29 <br /> primer-one coat <br /> 105. Paint more than the walls-one 611.6.17 SF 0.00 0.59 42.76 72.70 479.00 <br /> coat <br /> 106. Paint door/window trim&jamb- 5.00 EA 0.00 27.35 16.08 27.36 180.19 <br /> 2 coats(per side) <br /> 107. Painter-per hour 4.00 HR 0.00 65.43 30.78 52.34 344.84 <br /> 108. Window stool&apron-Detach 60.00 LF 0.00 2.70 19.06 32.40 213.46 <br /> &reset <br /> The window bumpout involves complexity and may involve detaching all the window jambs so the walls can be installed.This is only for the <br /> window bumpout and old wood framing.An FNC bid will be provided if this line item does not cover the cost to address this complex portion of the <br /> repair. See photos. <br /> CEILING <br /> 109. Outlet or switch cover 7.00 EA 0.00 2.95 •2.42 4.14 27.21 <br /> 110. Light fixture 1.00 EA 0.00 71.51 8.41 14.30 94.22 <br /> FLOORS <br /> 111. 1"x 6"lumber(.5 BF per i,F) 20.00 LF 0.00 2.28 5.36 9.12 60.08 <br /> 112. Sand,stain,and finish wood floor 242.50 SF 0.00 4.08 116.35 197.88 1,303.63 <br /> 113. Add for dustless floor sanding 242.50 SF 0.00 1.00 28.52 48.50 319.52 <br /> WK-19-0143-R-DASH 12/18/2019 Page: 111 <br />