0 0 <br /> Mallorie Hefley <br /> Fullwiler Construction Inc. <br /> Plan Check Number: B2106-047, First Building Review <br /> July 29, 2021 <br /> Non-Structural <br /> 1. The referenced codes should be updated to the 2018 editions. R106.1.1 <br /> 2. The roof eaves project approximately 3 feet from the property line in multiple locations per the <br /> site plan. In those locations, one-hour construction is required on the underside of the eaves (see <br /> alternatives and exceptions provided). In most solutions, the soffit venting will not be permitted <br /> in the eaves in these locations and the roof venting should be relocated to an approved location. <br /> Table R302.1(1) <br /> 3. A handrail should be shown at the stairs on the floor plan in compliance with Section R311.7.8. <br /> 4. A smoke alarm should be provided on the lower level and in the office. Section R314 <br /> 5. A carbon monoxide alarm should be provided on the lower level. Section R315 <br /> 6. The 4x4's in the crawl space should be shown as pressure treated. Section R317.1.4 <br /> 7. The mechanical equipment in the garage should be shown to be protected from vehicular damage <br /> by a bollard or other approved protective method. M1307.3.1 <br /> 8. The plans should show that the building is required to undergo an air leakage test (performed by <br /> a licensed 3rd party agency). The testing requirements should be shown on the plans according <br /> to WA State Energy Code Section R402.4. <br /> 9. Duct testing is required per WA ST Energy Code Section R403.3.3 (see exceptions). The plans <br /> should note the testing requirements. <br /> 10.The plans should show a heat pump per the project energy credits. Plans currently show a <br /> furnace. WA State Energy Code Table R406.2 <br /> 11.The plans should show an electric heat pump water heater per the project energy credits. WA <br /> State Energy Code Table R406.3 <br /> 12. Floor plans should show a landing outside of each exterior door. See exit from garage. R311.3 <br /> O3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.