GeoTest Services, Inc. October 8, 2021 <br /> 2405 Hillside Lane, Everett,WA Project No.21-0845 <br /> mem= imumme <br /> PURPOSE AND SCOPE OF SERVICES <br /> The purpose of this evaluation is to establish general subsurface conditions beneath the site from <br /> which conclusions and recommendations pertaining to project design can be formulated. Our <br /> scope of services includes the following tasks: <br /> • Explore soil and groundwater conditions underlying the site by advancing 3 test pit <br /> explorations via a track-mounted excavator provided by Fullwiler Construction, Inc. <br /> • Perform laboratory testing on representative samples to classify and evaluate the <br /> engineering characteristics of the soils encountered and to assess on-site infiltration <br /> capability. <br /> • Provide a written report containing a description of subsurface conditions and exploration <br /> logs. The findings and recommendations in this report pertain to site preparation and <br /> earthwork, fill and compaction, seismic design, foundation recommendations, concrete <br /> slab-on-grade construction, foundation and site drainage, infiltration feasibility, <br /> temporary and permanent slopes, geotechnical consultation, and construction <br /> monitoring. <br /> • Assess Geologically Hazardous Areas (if present) per Everett Municipal Code (EMC). <br /> PROJECT DESCRIPTION <br /> The rectangular-shaped, approximately 0.68-acre subject property is located west of 24th Ave. <br /> W. and south of W. Mukilteo Boulevard in Everett, WA.The project site contains three lots(Lots <br /> 2, 3,and 4) of a 4-lot short-plat. Lot 1 is located to the south of the proposed development(2405 <br /> Hillside Drive). This lot contains a single-family residence and will remain unchanged as part of <br /> the new development.The owner of Lot 1 currently owns the three lots described here as of the <br /> writing of this report. An existing driveway originating from 24th Ave. W. serves as access to the <br /> future homes.GeoTest understands that the subject property will be developed into three single <br /> family residences. <br /> Due to the presence of an approximately 32-foot-high slope that comprises the subject property, <br /> it is expected that some site grading will be required to establish the 3 buildable lots. Preliminary <br /> information regarding infiltration or stormwater detention facilities was not available at the time <br /> that this report was written. An existing stormwater detention facility exists in the proximity of <br /> the private road. Design details of this facility were unavailable at the time that this report was <br /> written. <br /> 1 <br />