3/11/2020 City of Everett Page i <br /> 6:53:08AM <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. E2001-197 Site Address 5117 SEAVIEW WAY <br /> Applied 1/30/2020 Applicant TIFFANY ERICKSON Lot <br /> Approved 1/30/2020 Owner THOMAS TORRENCY&CYNTHIA Block <br /> Issued 1/31/2020 Contractor SWITCH ELECTRIC LLC Tract <br /> Parent Permit No. B1907-030 Description 200 A SUBPANEL AND 4-20A CIRCUITS IN NEW GARAGE <br /> Notes PERMIT CONDITIONS: <br /> 1.Downspouts shall discharge to splash blocks. <br /> 2.Erosion control measures shall be installed. <br /> 3.No dirt,etc.to be tracked onto roadway. <br /> (11/4/2019 10:39 AM TAH) <br /> UNHEATED SPACE PER APPLICANT,2015 IRC <br /> Scheduled Completed Tyne Inspector Result Remarks Inspector's Comments <br /> 2/26/2020 2/26/2020 ELEC 06-ROUGH SKB CORRECTION (2/26/2020 10:58 AM SKB) <br /> IN Raise 240 V receptacles about 18 inches in <br /> the garage.A fourth conductor from the <br /> building to the shop for grounding is <br /> required in the feeder conduit. <br /> 2/26/2020 2/26/2020 ELEC 09-FINAL SKB CORRECTION (2/26/2020 10:58 AM SKB) <br /> GFCI Breakers do not test out at the <br /> receptacles.I believe this is because of the <br /> missing fourth ground wire causing too <br /> much resistance verify GFCI breakers trip <br /> from receptacles PRIOR to reinspection. <br /> 2/26/2020 2/26/2020 ELEC 02-GROUND SKB APPROVAL as noted. (2/26/2020 10:58 AM SKB) <br /> WORK Provide caution tape above shallow conduit. <br /> 3/10/2020 3/10/2020 ELEC 09-FINAL SKB APPRVD-PERN <br /> 3/10/2020 3/10/2020 ELEC 06-ROUGH SKB APPROVAL <br /> IN <br /> 3/10/2020 3/10/2020 ADMIN USE KLC APPROVAL <br /> ONLY** <br /> INSP12 <br /> C <br />
The URL can be used to link to this page
Your browser does not support the video tag.