My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2920 TERMINAL AVE 2023-06-23
>
Address Records
>
TERMINAL AVE
>
2920
>
2920 TERMINAL AVE 2023-06-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2023 8:42:37 AM
Creation date
6/23/2023 8:42:28 AM
Metadata
Fields
Template:
Address Document
Street Name
TERMINAL AVE
Street Number
2920
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
41/ • <br /> WAC 29646B-900 ECTRICAL PLAN REVIEW <br /> DIRECTIONS: Read the WAC section below to determine if plan review is required or not required.Then select the box next to(a)to <br /> tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-46B-900 If plan review is <br /> required,select the box next to(b)and(c)to acknowledge that plan review is required and the electrical plans have been provided <br /> with this permit application. <br /> *if item(a)-(ii,iii,or v)is selected,the work must also comply with section(a)-(vil).See arrow flow chart below. <br /> (3)Electrical plan review. <br /> 11 (a)Electrical plan review is not required for: <br /> 0 (i)Low voltage systems; <br /> ❑ (ii)Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br /> ■ (iii)Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br /> involved in the project,provided there is not a corresponding increase in the available fault current in any feeder. <br /> ❑ (iv)Stand-alone utility fed services that do not exceed 250 volts,400 amperes where the project's distribution system <br /> does not include: <br /> (A)Emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (B)An essential electrical system defined in NEC 517.2;or <br /> (C)A required fire pump system. <br /> ■ (v)Modifications to existing electrical installations where all of the following conditions are met: <br /> (A)Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br /> 250 volts or for lighting circuits not exceeding 277 volts to ground; <br /> (B)Does not involve emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (C)Does not involve branch circuits or feeders of an essential electrical system as defined in NEC 517.2; <br /> and <br /> (D)Service or feeder load calculations are increased by 5%or less. <br /> (vi)Electric power production source(s)such as solar photovoltaic,fuel cell,or wind electric system(s)with a total❑ <br /> rating of 9600 watts or less. <br /> (vli)For installations in(a)(ii),(ill),and(v)of this subsection to be considered,the following must be available <br /> ■ to the electrical inspector before the work is initiated: <br /> (A)A clear and adequate description of the project's scope; <br /> (B)A load calculation(s); <br /> (C)What the load changes are,providing both before and after panel schedules as needed;and <br /> (0)Provide information showing that the service and feeder(s)supplying the panel(s)where the work is <br /> taking place has adequate capacity for any increased load and has code compliant overcurrent protection <br /> for that supply. <br /> NOTE: Electrical plan review is not required for"Medical,dental,and chiropractic clinic"of which is a clinic or <br /> ❑ physicians'office where patients are not regularly kept as bed patients for twenty-four hours or more,per section <br /> (1)(c)(xii). <br /> ❑ (b)Electrical plan review is required for all other new or altered electrical projects in educational,institutional,or health care <br /> occupancies defined in this chapter. <br /> (c)If a review is required,the electrical plan must be submitted for review and approval before the electrical work is begun. <br /> Table 0001 Table 9004 <br /> Health or Personal Care Facilities Educational and Institutional Facilities.Places of Assembly,or Other Facilities <br /> Health or-Personal Care Facility Plan Review <br /> Type Required Educational,Institutional,or Plan Review <br /> HaspstaE Yes Other Facility Types Required <br /> Nursing home unit or long-term Yes Educat. nal 'fes <br /> care unit iri5titutianal Yes <br /> Boaraing home Yes <br /> Assisted living facility Yes <br /> Private alcoholism hospita Yes Notes to Tables 900-1 and 900-2. <br /> Private psychiatric hospital Yes `..A city at.thorized to Co electrical inspections <br /> Maternty home Yes may regtsre plan review on lacii7 y types not <br /> Ambulatory surgery faculty Yes reviewed by the department. <br /> Renal hemodialysbb c€inic Yes <br /> Reslcentlal treatment facility Yes <br /> Enhanced service facility Yes <br /> Adult residentia=rehabilitation Yes PERMIT# Page 2-Plan Review <br /> center <br />
The URL can be used to link to this page
Your browser does not support the video tag.