My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2605 15TH ST T MOBILE ANTENNA 2023-07-03
>
Address Records
>
15TH ST
>
2605
>
T MOBILE ANTENNA
>
2605 15TH ST T MOBILE ANTENNA 2023-07-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/3/2023 8:57:37 AM
Creation date
6/23/2023 10:49:38 AM
Metadata
Fields
Template:
Address Document
Street Name
15TH ST
Street Number
2605
Tenant Name
T MOBILE ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"4- C 2 E <br /> NOTE: N <br /> #6 AWG FROM ANTENNA GROUND BARS AT BOTTOM OF <br /> CABLE GROUND KIT \ TOWERS/MONOPOLES SHALL/ \ ONLY USE EXOTHERMIC WELDS. i <br /> T <br /> Mob•le- <br /> , 1 <br /> GROUND BAR ON 19807 NORTH CREEK PKWY N <br /> WALL ICE BRIDGE, — r — 1 — BOTHELL,WA 98011 <br /> CONCRETE,OR ON <br /> ANTENNA TOWER-1 <br /> ©000 t(9'° c); @smartlink <br /> FjOOO O O Og OO 11232 120TH AVE NE,SUITE 204 <br /> 0 KIRKLAND,WA 98033 l <br /> I <br /> 'TWO HOLE LUG,OR ELD TO BE <br /> U SE WITH#2 AWG BC(W TO BUILDING SERVICE \_...' I N F I N I G Yg, <br /> GROUND OR GROUND RING — FROM ZERO TO INFINIGY <br /> I GROUND CONDUCTOR SHALL BE ELIMINATED the solutions are endless <br /> WHEN GROUND BAR IS ELECTRICALLY BONDED '�- <br /> TO METAL TOWER/MONOPOLE STRUCTURE 2500 W.HIGGINS RD.STE.500 <br /> HOFFMAN ESTATES,IL 60169 J <br /> JOB NUMBER 4106-00004-C <br /> 12 NOT USED xE 11 NOT USED xE 10 NOT USED s+E 9 GROUND WIRE INSTALLATION I NOT TO <br /> 1.) COPPER GROUND BAR,1/4"x 4"x 20",NEWTON INSTRUMENT CO. T-MOBILE SITE: <br /> CAT.NO.B-6142 OR APPROVED EQUAL HOLE CENTERS TO MATCH SE01452A <br /> NEMA DOUBLE LUG CONFIGURATION.(ACTUAL GROUND BAR SIZE DELTA-EVERETT HOUSING <br /> VNLL VARY BASED ON NUMBER OF GROUND CONNECTIONS) <br /> 2.) 5/8"LOCK WASHERS,NEWTON INSTRUMENT CO. AUTHORITY-SE54XC090 <br /> CAT.NO.3015-8 OR APPROVED EQUAL <br /> 3.) WALL MOUNTING BRACKET,NEWTON INSTRUMENT CO. <br /> CAT NO.A-6056 OR APPROVED EQUAL 2605 15TH STREET <br /> 4.) 5/8-11 X 1"HHCS BOLTS,NEWTON INSTRUMENT CO. EVERETT,WA 98201 <br /> CAT NO.3012-1 OR APPROVED EQUAL <br /> O SNOHOMISH COUNTY <br /> :C.rrr <br /> 0 7/16" @ 3/4" 0 ° <br /> f�irrnurn 2" 0 ° ° 0 0 <br /> 0 0 °1 0 D o D 66-0"ROOFTOP <br /> o� o <br /> 0 ‘0'?"' <br /> 40 ° °''0 ° Q <br /> ° ° ° DRAWINGS ISSUED FOR: <br /> 1 / REV. DATE DRAWN DESCRIPTION WOG <br /> NOTES: <br /> GROUND BAR AT ANTENNA LEVEL TO BE BONDED DIRECTLY TO TOWER A 04/13/21 RCD PRELIMNARV REVIEW ER <br /> STRUCTURE;NO INSULATORS USED.GROUND BAR AT BASE OF TOWER B 05/10/21 CAP PREUMNARY REVIEW ER <br /> STRUCTURE TO BE ATTACHED VNTH INSULATORS.CONNECTION TO TOWER 0 osTzsat CAP +06 i CONSTRUCTION ER <br /> STRUCTURE SHALL BE PER MANUFACTURERS RECOMMENDATIONS. <br /> 8 NOT USED A_E 7 NOT USED NsOATLIED <br /> 6 NOT USED E 5 TYPICAL GROUND BAR I NOT TO <br /> SCALE <br /> TO ANTENNAS NOTES: <br /> 1. DO NOT INSTALL CABLE tz•To(TYPICALLY) <br /> \ ANTENNA CABLE yy y <br /> GROUND KIT AT A BEND r a � tzo-Max "I <br /> AND ALWAYS DIRECT S I • <br /> RX2 Y TX1/RX1 GROUND WIRE DOWN TO _ •:- <br /> �� ram_ !�� ■ ANTENNA GROUND BAR. Qf• �4. <br /> �#.� • COAX JUMPER WEATHERPROOFING KIT �� ) ►:. �t <br /> TYPE TA TYPE VN 34, TYPE NC TYPE SS �P) f 2 SHALL BEWEATHERPROOFING (SEE(SEE NOTE 3) �j r,/,' <br /> CONNECTOR ■ TAPE KIT.COLD SHRINK CABLE GROUND KIT CABLE ,�/ <br /> `1 WEATHERPROOFING • SHALL NOT BE USED. CONNECTOR ,4. 6/2/1 <br /> Cam] ■ KIT(TYP)SEE NOTE 2 AWN WIRE COPPER r�Q�� �' <br /> e',) r._. (II/V, WEATHERPROOFING GROUND WIRE(GROUNDED TO • 1 LFQIg� <br /> KIT(TYP) GROUND BAR).SEE NOTES 1&2 S+ 0 <br /> TYPE VV TYPE VS TYPE VB TYPE PT GROUND KIT(TYP) `rf�NAl.�� <br /> ANTENNA CABLE <br /> TO EQUIPMENT(TYP) I. > #6 AWG NOTES: <br /> ' '\ <br /> II( di <br /> 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND <br /> [l��;;; \I�\ ANTENNA GROUND BAR, ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. SHEET TITLE. <br /> MI WITHOUT INSULATORS. GROUNDING <br /> BONDED DIRECTLY TO 2.GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS <br /> TYPE GT TYPE GY TYPE GR TYPE GL I I MONOPOLE OR TOWER SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. DETAILS <br /> AT ANTENNA LEVEL. <br /> ' 3. WEATHERPROOFING SHALL BE TWO-PART TAPE KIT,COLD <br /> SHRINK SHALL NOT BE USED. SHEET NUMBER: REVISION: <br /> TO GROUND RING <br /> 0 <br /> 4 EXOTHERMIC CONNECTIONS NEE s� <br /> 3 CABLE GROUND CONNECTIONS E �°2 CABLE GROUND KIT 1 NOT USED <br /> -2 <br /> THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORAORATED HEREIN AS AN INSTRUMENT OF PROFESSIONAL SERVICE ARE THE PROPERTY OF INFINIGY ENGINEERING,AI LC AND ARE NOT TO RE USED.IN WHOLE OR IN HART.FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEE.RII,G,PI I.C.IT IS UNLAWFUL FOR ANY PERSON'0 AMEND ANY ASPECT 0-THESE DRAWINGS W WITHOUT'-F WRITTEN APPROVAL OF THE PROFESSIONAL OF PECORD. <br />
The URL can be used to link to this page
Your browser does not support the video tag.