Laserfiche WebLink
SOLAR MODULE SPECIFICATIONS T I I C L I I T R l0NAE\jNNklM3M • <br /> MANUFACTURER/MODEL Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) Lumlo <br /> VMP 37.13 V R BRANCH CIRCUIT #1 OF 11 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.55% SMARTENERGYTODAY <br /> IMP 10.77 A R BRANCH CIRCUIT #2 OF 9 IQ8PLUS MICROS, THE VOLTAGE RISE ON THE 240 VAC Q CABLE IS 0.38% (SET) <br /> 1550 DIGITAL DR,LEHI,UT <br /> VOC 45.3 V LTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX 4C 84043,USA <br /> ISC 11.14 A ISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN FT. <br /> TEMP. COEFF. VOC -0.27%/K 1.21 AMP X 11) X (0.00205 OHMS/FT) X (21 FT X 2) <br /> PTC RATING 376.55 W <br /> 3.31 AMPS X 0.00205 OHMS/FT) X 42 FT <br /> MODULE DIMENSION 74"(L)x 41.1"(W) <br /> PANEL WATTAGE 400 W 15 VOLTS SYSTEM INFO <br /> VRISE = 1.15 VOLTS = 240 VOLTS = 0.48% (20)Q CELLS <br /> INVERTER SPECIFICATIONS E VOLTAGE RISE FROM THE JUNCTION BOX TO THE IQ COMBINER BOX 4C IS 0.48% Q.PEAKDUOBLKML-G10+ <br /> MANUFACTURER/MODEL ENPHASE IQ8PLUS-72-2 US (240V) (ENPH <br /> LTAGE RISE FROM THE IQ COMBINER BOX 4C TO THE FUSED AC DISCONNECT (US-72- -US( <br /> MAX DC SHORT CIRCUIT CURRENT 15 A IQ8PLUS-72-2-US(240V) <br /> CONTINUOUS OUTPUT CURRENT 1.21 A ISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN F .) DC SYSTEM SIZE:8.000kWDC <br /> AMBIENT TEMPERATURE SPECS 1.21 AMP X 20) X (0.00051 OHMS/FT) X (5 FT X 2) AC SYSTEM SIZE:6.000 kWAC <br /> RECORD LOW TEMP -5°C 4.20 AMPS X 0.00051 OHMS/FT) X 10 FT <br /> AMBIENT TEMP (HIGH TEMP 2%) 26°C .12 VOLTS REVISIONS <br /> CONDUIT HEIGHT 7/8" VRISE = 0.12 VOLTS - 240 VOLTS = 0.05% DESCRIPTION DATE REV <br /> ROOF TOP TEMP 90°C E VOLTAGE RISE FROM THE IQ COMBINER BOX 4C TO THE FUSED AC DISCONNECT IS 0.05% REVISION 12/17/2022 A <br /> CONDUCTOR TEMPERATURE RATE 48°C LTAGE RISE FROM THE FUSED AC DISCONNECT TO THE MSP REVISION 01/19/2023 B <br /> MODULE TEMPERATURE COEFFICIENT OF VOC -0.27%/K ISE = (AMPS/INVERTER X NUMBER OF INVERTERS) X (RESISTANCE IN OHMS/FT.) X (2-WAY WIRE LENGTH IN F .) <br /> PERCENT OF VALUES NUMBER OF CURRENT CARRYING 1.21 AMP X 20) X (0.00051 OHMS/FT) X (14 FT X 2) PROJECT NAME&ADDRESS <br /> CONDUCTORS IN EMT <br /> 0.80 4-6 4.20 AMPS X 0.00051 OHMS/FT) X 28 FT U) <br /> 0.70 7-9 .35 VOLTS <br /> 0.50 10-20 ° VRISE = 0.35 VOLTS - 240 VOLTS = 0.14% o <br /> E VOLTAGE RISE FROM THE FUSED AC DISCONNECT TO THE MSP IS 0.14% 000 <br /> rn <br /> TOTAL SYSTEM VOLTAGE RISE FOR ALL WIRE SECTIONS U o <br /> Lu cy) <br /> 55% + 0.48% + 0.05% + 0.14% = 1.22% ww <br /> O U 0 <br /> = z w It <br /> Lu o w <br /> Q w > CD <br /> C7 Q .. <br /> J :tt <br /> CALCULATION < Q <br /> CHANGED <br /> O <br /> 0 <br /> U <br /> N <br /> O <br /> Lo <br /> DATE: 1/19/2023 <br /> SHEET NAME <br /> SPECIFICATIONS <br /> & NOTES <br /> SHEET SIZE <br /> ANSI B <br /> 11" X 17" <br /> SHEET NUMBER <br /> PV-8 <br />