Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This tool will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br /> Please complete the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some <br /> values will be calculated for you. If you do not see the selection you need in the drop-down options,please contact the WSU Energy Program at <br /> energycode@energy.wsu.edu or(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Pannu Addition Bikrampal Pannu <br /> 2126-124th St.S.E.Everett,WA 98208 425.530.2086 <br /> Heating System Type: O All Other Systems o Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions" <br /> Design Temperature <br /> Instructions Design Temperature Difference(AT) 47 <br /> Everett JC AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 846 <br /> Average Ceiling Height Conditioned Volume <br /> instructions Average Ceiling Height(ft) 9.0 7,614 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> I j u o 3a v i 0.300 69 20.64 <br /> Skylights U-Factor X Area = UA <br /> instructions 0.50 8 4.00 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions' R 49 j 0.026 846 22.00 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> 1.7,fr"";>.r.s ,Select R-Value u v J No selection <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> tnstrtscti:,ns i R-21 Intermediate v 0.056 714 40.00 <br /> Floors U-Factor X Area UA <br /> Instructions 1 ]]] 0.029 846 24.53 <br /> l ,1R30 <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> iri tructkms No selection <br /> I !Select R-value v --- <br /> Slab Below Grade(see Figure 1) F-Factor X Length UA <br /> Instructions <br /> { INo selection Selectconditioning v - --- <br /> Slab on Grade(see Figure 1) F-Factor X Length UA <br /> Instructions I No selection <br /> 'Select R Value V --- <br /> av � <br /> Location of Ducts <br /> Instructions Duct Leakage Coefficient <br /> } i Unconditioned Space <br /> 1.10 <br /> Sum of UA 111.17 <br /> Envelope Heat Load 5,225 Btu/Hour <br /> Figure 1. Sum of UA x AT <br /> Air Leakage Heat Load 3,865 Btu/Hour <br /> ",` Volume x 0.6 x AT x 0.018 <br /> Above Grade i Building Design Heat Load 9,090 Btu/Hour <br /> 1 Air leakage+envelope heat loss <br /> Building and Duct Heat Load 9,999 Btu/Hour <br /> Ducts in unconditioned space:sum of building heat loss x 1.10 I <br /> I l <br /> Ducts in conditioned space:sum of building heat loss x 1 <br /> Maximum Heat Equipment Output 12,498 Btu/Hour <br /> Building and duct heat loss x 1.40 for forced air furnace7.71/1.4(...,' <br /> Building and duct heat loss x 1.25 for heat pump <br /> (07/01/13) <br />