My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2126 124TH ST SE 2023-07-03
>
Address Records
>
124TH ST SE
>
2126
>
2126 124TH ST SE 2023-07-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/3/2023 1:53:42 PM
Creation date
6/26/2023 9:29:34 AM
Metadata
Fields
Template:
Address Document
Street Name
124TH ST SE
Street Number
2126
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> 2018 Washington State Energy Code—Residential <br /> Prescriptive Energy Code Compliance for All Climate Zones in Washington <br /> axr f` � s" �'� a "°*+..,. .°'r,� p yam' e4,} - b P"� a k t" s�,t:€�" ''` a x.. a `c. <br /> .is< r ;, . , ,..,r: Mingle.'`` iAVEWew Q[' Ri e'ft aTi 4r4: ,2O2t _ N a t.., V .%1 z;` <br /> These requirements apply to all IRC building types,including detached one-and two-family <br /> dwellings and multiple single-family dwellings(townhouses). <br /> Project Information i Contact information <br /> Pannu Addition Bikrampal Pannu <br /> 2126-124th St.S.E.Everett,WA 98208 425.530.2086 <br /> Instructions:This single-family project will use the requirements of the Prescriptive Path below and <br /> incorporate the minimum values listed.Based on the size of the structure,the appropriate number of <br /> additional credits are checked as chosen by the permit applicant. <br /> Provide all information from the following tables as building permit drawings:Table R402.1-Insulation and <br /> Fenestration Requirements by Component,Table R406.2-Fuel Normalization Credits and 406.3-Energy Credits. <br /> !Authorized Representative 11 �2�- !Date 3-�3 <br /> All Climate Zones(Table R402.1.1 , <br /> R-Value a U-Factor a <br /> Fenestration U-Factor b n/a 0.30 <br /> 'Skylight U-Factor b n/a — 0.50 <br /> Glazed Fenestration SHGC b,e n/a n/a <br /> Ceiling e 4.9 0.026 <br /> Wood Frame Wall 21 int 0.056 <br /> l Floor 30 0.029 <br /> !Below Grade Wall c' 10/15/21 int+TB 0.042 <br /> 'Slab tR-Value&Depth 10, 2 ft n/a - <br /> 1 R-valu:es are minimums.U-factors and SHGC are maximums.When insulation is installed in a cavity that is less <br /> a Ithan the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix <br /> ITable A101.4 shall not be less than the R-value specified in the table. <br /> b 'The fenestration U-factor column excludes skylights. <br /> I"10/15/21+5TB"means R-10 continuous insulation on the exterior of the wall,or R-15 continuous insulation on <br /> the interior of the wall,or R-21 cavity insulation plus a thermal break between the slab and the basement wall at <br /> c ;the interior of the basement wall."10/15/21+5TB"shall be permitted to be met with R-13 cavity insulation on <br /> Ithe interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall."5TB" <br /> I means R-5 thermal break between floor slab and basement wall. <br /> d (R-10 continuous insulation is required under heated slab on grade floors.See Section R402.2.9.1. <br /> r !For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38 if the full insulation depth <br /> e I extends over the top plate of the exterior wall. <br /> i R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter <br /> f slab insulation when applied to existing slabs complying with Section R503.1.1.If foam plastic is used,it shall <br /> meet the requirements for thermal barriers protecting foam plastics. <br /> For log structures developed in compliance with Standard ICC 400,log walls shall meet the requirements for <br /> g ;climate zone 5 of ICC 400. <br /> lint.{intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard <br /> h framing 16 inches on center,78%of the wall cavity insulated and headers insulated with a minimum of R-10 <br /> insulation. <br /> Prescriptive Path-Single Family 2018 Washington State Energy Code-R 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.