Laserfiche WebLink
WSU Code Compliance Calculator,WSEC 2018 • <br /> Sum of Area and UAI 1,416I 1251 <br /> Floor(over crawl or exterior) <br /> Plan - Component - Floor - UA <br /> ID Description Ref. U Area <br /> R30 vented Joist 16oc(Code Baseline) 10-3 0.029 1,677 49 <br /> Sum of Area and UA 1,677 49 <br /> Slab on Grade(less than 2 feet below grade) <br /> Plan Component Slab <br /> ID Description Ref. F. Slab Perim FP <br /> Sum of Perimeter and FP 0 0 <br /> Below Grade Walls and Slabs <br /> Plan Component Wall Wall Wall Slab Slab <br /> ID Description Ref. U Area UA F Slab Perim : UA <br /> Sum of Area,Length and UA 0 0.0 0 0 <br /> Ventilation Requirements <br /> Number of Bedrooms - 3 <br /> Run-Time Percent in Each 4-Hour Segment 50% <br /> Is the system Balanced? Unbalanced <br /> Is the system Distributed? Not Distributed <br /> Ventilation Code Section IRC,Chapter 15 <br /> Whole House Mechanical Ventilation Airflow Rate 150 ICFM <br /> HVAC Thermal Distribution System Download RS-33(2018)-http:/tarrw.energv.wsu.edu/Documents/Duct/20Testinrt%20Standards%20 <br /> Is this a hydronic heating system? - No <br /> Location of Ducts Unconditioned Space <br /> Location of Air Handler Unconditioned Space <br /> Existing Construction: Are Any of These Exceptions True? <br /> Are ducts systems documented to have been previously sealed as confirmed through No <br /> field verification and diagnostic testing per RS-33? <br /> Is there less than 40 linear feet in unconditioned spaces? No <br /> Are existing duct systems constructed,insulated or sealed with asbestos? No <br /> Is the project an Addition less than 750 sf of conditioned floor area? No <br /> Is Duct Testing Required?Yes <br /> Maximum Duct Leakage:Is this a post-contruction test? No <br /> Is the air handler installed? No <br /> Maximum total measured duct leakage per square foot 0.03 CFM25 per sq.ft. <br /> Maximum allowable total measured duct leakage 50 CFM25 <br /> Links to Download Forms,Checklists and Other Resources Link <br /> Compliance Certificate Compliance Certificate Instructions <br /> Insulation Certificate for Residential New Construction Insulation Certificate <br /> Duct Testing Affadavits - Existing Construction Affidavit.Existing. <br /> New Construction Affidavit.New <br /> Prescriptive Checklist for 2018 WSEC Prescriptive Checklist <br /> Alterations(Remodel)Worksheet Worksheet <br /> Show Heating System Sizing?IShow <br /> Heating System Sizing-Proposed Design Try Out BetterBuiltNW's HVAC Sizing Tool:https://betterbuiltnwcom/resources/hvac-sizinq-tool r <br /> https://nelorgft3133465-my.sharepoint.com/personal/zeroenergyhomes_becenergy_net/Documents/Documents/00A1-BEC-2021/A1-Clients_2022_BEC/Jim Hollinger/Pannau Residence/WSU Forms/Existing Heat Load <br /> Calculations_Pannu.xlsm 3/21/2022 t 3/21/2022 <br /> t <br />